Pengembangan Model Real-Time Buck Converter pada FPGA untuk Pengujian Sistem Kendali Berbasis Hardware-in-the-Loop (HIL)
Nathan Bennett Chang, Dr.-Ing. Ir. Yohan Fajar Sidik, S.T., M.Eng.; Dzuhri Radityo Utomo, S.T., M.S., Ph.D.
2026 | Skripsi | TEKNIK ELEKTRO
Konverter buck merupakan komponen catu daya yang banyak digunakan, namun pengujian algoritma kendalinya pada perangkat keras nyata berisiko merusak komponen dan berbiaya tinggi. Penelitian ini mengembangkan platform Hardware-in-the-Loop (HIL) berbiaya rendah berbasis FPGA dan mikrokontroler STM32 untuk menguji kendali konverter buck secara aman, berfokus pada pemodelan, penalaan parameter, dan validasi arsitektur Cascaded Control.
Model plant konverter buck ideal (L = 10,37 mH, C = 244 µF, Vin = 24 V) diimplementasikan pada FPGA Cmod S7 menggunakan persamaan beda Forward Euler dalam representasi fixed-point Q16.16 dengan laju pembaruan 10 kHz. Mikrokontroler STM32 menjalankan algoritma kendali PI pada laju 10 kHz dan bertukar data dengan FPGA melalui antarmuka SPI 64-bit. Parameter kendali ditentukan melalui analisis domain frekuensi, dan sistem HIL lingkar tertutup divalidasi silang terhadap simulasi QSPICE. Kendali cascade dirancang dengan metode reduksi orde satu dan target phase margin 60 derajat (target crossover 556 Hz untuk loop dalam dan 55 Hz untuk loop luar, dikonfirmasi analisis Bode numerik pada 573 Hz dan 49 Hz).
Pengujian open-loop menunjukkan tegangan keluaran menyimpang hanya sekitar 0,1?ri nilai analitik Vout = D × Vin = 12 V yang tidak bergantung pada beban, dengan validasi silang QSPICE pada transien startup menghasilkan deviasi puncak 2,1% (RMSE 0,645 V setelah penyelarasan tunda rantai HIL) dan resonansi LC terkonfirmasi secara empiris pada 90,9 Hz (9,1% di bawah nilai analitik 100,1 Hz, terutama akibat redaman plant). Pada uji step beban (12 ohm ke 6 ohm), cascade menunjukkan undershoot 28,58?ngan settling 17,0 ms, berimpit dengan simulasi QSPICE (RMSE transien 0,1828 V, 1,52?ri Vref). Dengan demikian, platform HIL yang dikembangkan terbukti mampu memodelkan plant secara akurat, berkomunikasi andal pada 10 kHz, dan menjadi sarana aman serta valid untuk merancang dan menguji sistem kendali konverter buck, dengan kontroler cascade yang terbukti mampu memberikan peredaman resonansi secara aktif dan pembatasan arus induktor.
Buck converters are widely used power-supply components, yet testing their control algorithms on real hardware risks component damage and incurs high cost. This research develops a low-cost Hardware-in-the-Loop (HIL) platform based on an FPGA and an STM32 microcontroller to test buck converter control safely, focusing on the modeling, tuning, and validation of Cascaded Control.
An ideal buck converter plant (L = 10.37 mH, C = 244 µF, Vin = 24 V) is implemented on a Cmod S7 FPGA using the Forward Euler difference equation in Q16.16 fixed-point representation at a 10 kHz update rate. An STM32 microcontroller runs the PI control algorithm at 10 kHz and exchanges data with the FPGA over a 64-bit SPI interface. Controller parameters are determined through frequency-domain analysis, and the HIL closed-loop system is cross-validated against QSPICE simulation. The cascade controller is tuned through first-order reduction with a 60° phase-margin target, targeting the inner loop crossover at 556 Hz and outer loop at 55 Hz, with the exact Bode analysis confirming crossovers at 573 Hz and 49 Hz respectively.
Open-loop testing shows the output voltage deviates only about 0.1% from the analytic value Vout = D × Vin = 12 V, which is independent of load, with QSPICE cross-validation on the startup transient yielding a 2.1% peak deviation (RMSE 0.645 V after aligning the HIL chain delay) and an empirically confirmed LC resonance of 90.9 Hz (9.1?low the analytic 100.1 Hz, mainly due to plant damping). The 64-bit SPI transaction completes within about 51% of the 100 µs control period and operates stably without frame loss. Under load-step tests (12 ? to 6 ?), the cascade exhibits 28.58% undershoot with 17.0 ms settling, closely matching the QSPICE simulation (transient RMSE 0.1828 V, 1.52% of Vref). The developed HIL platform thus proves capable of accurately modeling the plant, communicating reliably at 10 kHz, and serving as a safe and valid means to design and test buck converter control systems, with the cascade controller effectively providing active resonance damping and current limiting.
Kata Kunci : Hardware-in-the-Loop, konverter buck, FPGA, kontrol cascade, peredaman aktif resonansi