Evaluasi Penambahan Perkuatan Temporary Bracing Dan RO-RO Shoring System Selama Proses Erection Untuk Mengatasi Momen Guling Proyek Pembangunan Jembatan Kereta Api Solo Balapan-Kadipiro Km 105+000 S/D 106+800 (Tahap I) Metode Pembebanan Desain Kekuatan Izin (DKI) Dan Desain Faktor Beban Dan Ketahanan (DFBK) SNI 1729 2020
Elis Citaningrum, Teguh Sudibyo, S.T.MM.T.,Ph.D.
2023 | Tugas Akhir | D4 TEKNIK PENGELOLAAN DAN PEMELIHARAAN INFRASTRUKTUR SIPIL
Simpang Joglo
merupakan simpang dengan 7 ruas jalan raya dimana terdapat jalur kereta api
Solo Balapan-Kadipiro ditengahnya. Pembangunan elevated rail Simpang
Joglo dilakukan untuk mengatasi tingginya tingkat perjalanan kereta api dimana
terdapat jembatan komposit pipa rangka baja sepanjang 273,4 m serta tinggi
konstruksi 30 m. Pemilihan metode erection dilakukan per-segment dengan
penambahan perkuatan RO-RO shoring system dan temporary bracing
untuk menjaga stabilitas jembatan selama proses erection.
Berdasarkan
analisis, RO-RO Shoring System memiliki SF 2,6 dan 2,05 berturut-turut dengan
metode pembebanan DKI dan DFBK nilai SF yang disyaratkan adalah ? 2,0 sesuai dengan
arahan KKJTJ. Mengacu SNI 1729 2020 nilai rasio kapasitas harus bernilai ? 1,0 untuk struktur dikatakan
aman. Dengan metode pembebanan DKI, cross beam 1-4 memiliki rasio
kapasitas lentur berturut-turut adalah 0,389 ; 0,297 ; 0,135 ; 0,084 , rasio
kapasitas geser 0,477 ; 0,242 ; 0,314 ; 0,222. Kaki shoring memiliki rasio
kapasitas lentur 0,021 dan rasio kapasitas tekan aksial 0,5. Dengan metode
pembebanan DFBK cross beam 1-4 memiliki rasio kapasitas lentur
berturut-turut adalah 0,361 ; 0,335
0,153 ; 0,094 serta rasio kapasitas geser 0,441 ; 0,308 ; 0,354 ; 0,248.
Kaki shoring memiliki rasio kapasitas lentur 0,029 dan rasio kapasitas tekan
aksial 0,7.
Nilai deformasi
lateral tanpa penambahan temporary bracing 130,12 mm. Batas deformasi
ijin yaitu 41,67 mm mengacu pada standar AISC, sehingga dapat menyebabkan
guling jembatan. Dengan temporary bracing deformasi lateral yang terjadi
adalah 5,29 mm, nilai deformasi dibawah batas ijin, sehingga temporary
bracing mampu mengatasi guling material jembatan. Nilai Rmax
tanpa temporary bracing 0,31 dan dengan temporary bracing adalah
0,13. Kontrol stabilitas temporary bracing menggunakan metode pembebanan
DFBK menghasilkan nilai Rmax 0,19 ,rasio kapasitas lentur 0,14 ,
rasio kapasitas geser 0,005 dan rasio kapasitas tekan aksial 0,15. Dengan
metode pembebanan DKI nilai Rmax 0,13 ,rasio kapasitas lentur 0,04 ,
rasio kapasitas geser 0,002 dan rasio kapasitas tekan aksial 0,08.
Simpang Joglo is an intersection with
7 highways where
there
is a
Solo
Balapan-Kadipiro railway line
in
the
middle.
The construction of the Simpang
Joglo elevated rail was carried out to overcome the high level of train travel
where there is a steel frame pipe composite bridge with a length of 273.4 m and
a construction height of 30 m. The selection of the erection method was carried
out by segmentation with the addition of RO-RO shoring system reinforcement and
temporary bracing to maintain the stability of the bridge during the erection
process.
Based on the analysis, the
RO-RO Shoring System has an SF of 2.6 and 2.05 respectively with the DKI and DFBK
loading method the required SF value is ? 2.0 according to the KKJTJ
directives. Referring to SNI 1729 2020 the value of the capacity ratio must be
? 1.0 for the structure to be said to be safe. With the DKI loading method,
cross beams 1-4 have a flexural capacity ratio of 0.389; 0.297 ; 0.135 ; 0.084
, shear capacity ratio 0.477 ; 0.242 ; 0.314 ; 0.222. The shoring leg has a
flexural capacity ratio of 0.021 and an axial compression capacity ratio of
0.5. With the DFBK cross beam 1-4 loading method, the flexural capacity ratios
respectively are 0.361 ; 0.335 0.153 ; 0.094 and shear capacity ratio 0.441 ;
0.308 ; 0.354 ; 0.248. The shoring leg has a flexural capacity ratio of 0.029
and an axial compression capacity ratio of 0.7.
The value of lateral
deformation without the addition of temporary bracing is 130.12 mm. The
allowable deformation limit is 41.67 mm according to the AISC standard, so that
it can cause overturning of the bridge. With temporary bracing, the lateral
deformation that occurs is 5.29 mm, the deformation value is below the
allowable limit, so that the temporary bracing is able to overcome overturning
of the bridge material. The Rmax value without temporary bracing is
0.31 and with temporary bracing is 0.13. Stability control of temporary bracing
using the DFBK loading method resulted in an Rmax value of 0.19, a
flexural capacity ratio of 0.14, a shear capacity ratio of 0.005 and an axial
compression capacity ratio of 0.15. With the DKI loading method, the Rmax
value is 0.13, the flexural capacity ratio is 0.04, the shear capacity ratio is
0.002 and the axial compression capacity ratio is 0.08.
Kata Kunci : RO-RO Shoring, Temporary Bracing, Guling, DKI, DFBK