Identifikasi Faktor - Faktor Yang Berhubungan Pada Kualitas Air Perusahaan Daerah Air Minum (PDAM) Kabupaten Wonogiri

ABDULLAH ISNAINI, Dr. Ir. Sarto, M.Sc.; Agus Suwarni, SKM, M.Kes.

2016 | Tesis | S2 Ilmu Kesehatan Masyarakat

Latar Belakang : Perusahaan Daerah Air Minum (PDAM) merupakan institusi milik daerah yang mempunyai fungsi menyelenggarakan pelayanan air bersih bagi masyarakat dan perlu melaksanakan pengawasan kualitas airnya baik kualitas fisik, bakteriologi dan kimia. Adapun dengan kualitas air yang baik dapat memberikan rasa aman bagi para konsumennya. Berdasarkan hasil pemeriksaan kualitas air oleh Dinas Kesehatan Kabupaten Wonogiri didapat 60,30 % tidak memenuhi standar baku mutu. Kualitas air yang tidak memenuhi standar ini dapat terjadi di air baku, air hasil olahan dan air sambungan rumah pelanggan. Adapun penyebabnya bisa berasal dari jenis sumber air baku, sistem pengolahan dalam chlorinasi dan pendistribusian ke pelanggan. Kualitas air yang baik dapat berdampak baik bagi kesehatan penggunanya. Tujuan : Penelitian ini bertujuan untuk mengidentifikasi faktor–faktor yang berhubungan pada kualitas air PDAM Kabupaten Wonogiri. Metode : Penelitian ini merupakan penelitian observasional dengan rancangan cross sectional. Analisis data dengan uji Mann-Whitney dan one way anova untuk mengetahui perbedaan Kualitas air dan uji Spearman-rho untuk mengetahui hubungannya dengan signifikan alfa = 0,05. Hasil : Kualitas air secara bakteriologis pada air baku dengan air olahan PDAM terdapat perbedaan dan air olahan dengan air sambungan rumah pelanggan PDAM ada perbedaan kualitas airnya secara bakteriologis. Hasil uji Mann-Whitney nilai p<0,05 ada pada jumlah Coliform pada air baku, air olahan dan air kran sambungan rumah pelanggan PDAM. Kualitas air secara kimiawi untuk parameter besi (Fe) dan kesadahan total tidak ada perbedaan yang signifikan baik pada air baku, air olahan maupun air kran sambungan rumah pelanggan PDAM dengan nilai p>0,05 pada uji statistik Mann-Whitney dan one way anova. Kualitas air pada sambungan rumah dilakukan uji hubungan dengan Spearman-rho didapat hasil tidak ada hubungan antara jarak dengan Coliform dan jarak dengan kesadahan total dengan nilai p>0,05, sedangkan jarak dengan besi, jarak dengan sisa klor dan sisa klor dengan Coliform terdapat hubungan yang signifikan dengan nilai p<0,05. Kesimpulan : Kualias air secara bakteriologi belum semua memenuhi standar dan kualitas air secara kimiawi yang meliputi parameter besi dan kesadahan total telah sesuai standar baku mutu baik di air baku, air olahan dan air sambungan rumah pelanggan PDAM

Background : Local Water Company (LWC) is a county-owned institution that has the function of organizing water services for the community and the need to carry out monitoring water quality good physical quality, bacteriological and chemical. As with good water quality can provide a sense of security for its customers. Based on the results of water quality checks by the Health Service Wonogiri gained 60.30% do not meet quality standards. Water quality does not meet this standard may occur in raw water, processed water, and the water connection is the customer's home. The cause could be derived from the type of raw water source, treatment systems in chlorination and distribution to customers. Good water quality can be good for the health of users. Objective : This study aims to identify factors that affect the quality of water at PDAM Wonogiri. Method : This study was an observational studied with cross sectional design. Analysis of the data by the Mann-Whitney test and one-way anova to determine differences in water quality and Spearman-rho test to determine its relationship with significant at alfa = 0.05 Result : Bacteriological water quality of the raw water with treated water and water PDAM there are differences in the processed water house connections PDAM customers there are differences in the bacteriological water quality. Results of Mann-Whitney test p-value <0.05 is in the amount of Coliform in the raw water, process water and water connection PDAM customer homes. Chemical water quality parameters for iron (Fe) and total hardness no significant differences either in the raw water, process water and water connection PDAM customer homes with a value of p> 0.05 on the Mann-Whitney statistical test and one way anova. The quality of water in the home connection test Spearman-rho correlation with the result there is no relation between the distance with Coliform and distance with a total hardness with a value of p> 0.05, while the distance with the iron, the distance to the residual chlorine and chlorine residual with an association Coliform significant with p <0.05 Conclusion : Bacteriological water quality standards and not all meet the water quality parameters are chemically covering iron and total hardness are compliant quality standards both in the raw water, process water and water connection PDAM customer homes

Kata Kunci : Kualitas air, air baku, air olahan, air sambungan rumah, quality of water, raw water, treated water, water house connection