PERKUATAN SAMBUNGAN TIANG PANCANG PERSEGI MENGGUNAKAN BAJA PROFIL SIKU
FARUQ ARDIANSYAH, Ashar Saputra, ST., MT., Ph.D.
2016 | Skripsi | S1 TEKNIK SIPILPada pembangunan Pile Slab Martadipura, dilakukan penyambungan tiang pancang dengan beton cor karena ketinggian tiang pancang tidak memenuhi. Penyambungan yang dilakukan dikhawatirkan tidak mampu menahan beban yang disyaratkan sehingga dilakukan usaha perkuatan menggunakan baja profil siku. Penelitian ini bertujuan untuk mengetahui kekuatan dan perilaku sambungan tiang pancang persegi menggunakan perkuatan baja profil siku. Penelitian dilakukan dengan membuat 3 benda uji sambungan tiang pancang: tanpa menggunakan perkuatan (BU 1), menggunakan perkuatan baja siku panjang 1 m (BU 2), menggunakan perkuatan baja siku panjang 2 m (BU 3). Dimensi benda uji 400 x 400 x 5000 cm, mutu beton cor di tempat K-400 dan tiang pancang K-500, panjang penyaluran 50 cm, baja siku ukuran 100.100.10. Pengujian dilakukan berdasarkan metode JIS A 5326, yakni meletakkan benda uji pada tumpuan sendi dan rol, kemudian dibebani 2 tumpuan pada tiap 1/6 tengah bentang sampai benda uji runtuh. Hasil pengujian menunjukkan bahwa sebelum terjadi retak 0,3 mm, BU 3 memiliki kuat dukung paling besar yakni 390 kN atau momen 239,28 kNm. Dibandingkan dengan BU 2 sebesar 292,2 kN atau momen 180,6 kNm dan BU 1 sebesar 90,7 kN atau momen 59,7 kNm. Pada kondisi first crack BU 2 memiliki nilai defleksi yang paling besar yakni 1,98 mm. Dibandingkan dengan BU 3 yang sebesar 1,42 mm dan BU 1 yang sebesar 1,12 mm. Pola retak keruntuhan pada BU 1, BU 2, dan BU 3 merupakan pola retak kegagalan lentur.
During the construction of Martadipura Pile Slab, pile connections using cast-in-place concrete were used because the height of the piles did not meet the requirement. The pile connections that have been done were estimated unable to withstand the required load, so that an L profile steel reinforcement was applied. The study aims to examine the strength and the behaviour of the pile connections using L profile steel reinforcement. The research was done by making 3 kinds of connection pile specimens: without reinforcement (BU 1), with 1 m long L profile steel reinforcement (BU 2), with 2 m long L profile steel reinforcement (BU 3). The dimension of the specimens was 400 x 400 x 5000 cm. The quality of cast in place concrete was of K-400, and of piles was of K-500. The overlapping length was 50 cm. The dimension of L profile steel was 100.100.10. The tests were carried out based on JIS A 5326 method by first putting specimens on joint and roller supports and then applying 2 loads at each 1/6 midspan until the specimen collapse. The results of the test showed that before the crack of 0,3 mm, BU 3 has the greatest support capacity of 390 kN or moment 239,28 kNm, compared with BU 2 that has the support capacity of 292,2 kN or moment 180,6 kNm and BU 1 of 90,7 kN or moment 59,7 kNm. During the first crack, BU 2 has the greatest deflection number of 1.98 mm, while BU 3 has the deflection number of 1.42 mm and BU 1 of 1.12 mm. The failure crack patterns of BU 1, BU 2, and BU 3 are categorized as flexural crack failure.
Kata Kunci : Conection pile, L profile steel, JIS A 5326