Laporkan Masalah

ANALISIS ARC FLASH HAZARD DAN PENENTUAN LEVEL PPE DI MGT 1 - 5 PT CHEVRON PACIFIC INDONESIA

DIMAS ALDIANDRA A, Avrin Nur Widiastuti, S.T., M.Eng ; Prof. Sasongko Pramono Hadi., Dr., Ir..DEA.

2016 | Skripsi | S1 TEKNIK ELEKTRO

Dewasa ini masalah keamanan dalam bekerja menjadi salah satu tolak ukur kredibilitas suatu perusahaan, terutama perusahaan migas dan pertambangan. PT Chevron Pacific Indonesia (CPI) ialah salah satu perusahaan minyak di Indonesia yang telah beroperasi selama kurang lebih 90 tahun. Telah banyak kejadian atau permasalaha menyangkut keamanan yang terjadi di perusahaan tersebut, salah satunya ialah bahaya arc flash yang kerap kali terjadi di sistem kelistrikan PT CPI, khususnya pada Minas Gas Turbine (MGT) 1 - 5. Hal ini menandakan masih buruknya sistem penjagaan atau antisipasi mengenai potensi bahaya yang terjadi di MGT 1 - 5. Pada penelitian ini dilakukan simulasi arc flash hazard dengan menggunakan software ETAP 12.6 pada MGT 1 - 5 untuk mengetahui besar potensi incident energy, jarak arc flash boundary, dan energy level pada tiap panel. Panel - panel tersebut direpresentasikan sebagai bus dalam konfigurasi MGT 1 - 5 di ETAP 12.6. Hasil dari penelitian ini didapatkan nilai incident energy pada masing - masing panel dengan rentang 0,2 - 43 cal/cm2, arc flash boundary dengan rentang nilai 0,5 - 17 ft, dan energy level dengan rincian empat panel pada level 0, lima panel pada level 1, satu panel pada level 2, dan satu panel dengan level > max. Nilai terbesar untuk ketiganya berada pada bus 25.

Nowadays, safety problems in work environment has been one of its strong determinants for their image of credibility, especially for mining and oil and gas companies. PT Chevron Pacific Indonesia (CPI) is one of big oil companies in the world which had been operating in indonesia for approximately 90 years. There were so many problems or accidents regarding to safety problems that has been happened in Chevron, one of which is about arc flash hazard which had been frequently happened in Chevron's electrical system especially in Minas Gas Turbine (MGT). These incidents shows that safety standard or safety systems in Chevron is still low. In this study we do the arc flash hazard simulation using ETAP 12.6 for MGT 1 - 5 to observe the probability value of incident energy, arc flash boundary, and energy level in each panel. These panels represented by buses in the configuration of MGT 1 - 5 in ETAP 12.6 From this study, we got the value of incident energy for each panels which has range of 0,2 - 43 cal/cm2, flash protection boundary for each panels which has range of 0,5 - 17 ft, and the energy level with 4 panels in level 0, five panels in level 1, one panel in level 2, and one level in level > max. The greatest value of that three elements is at bus 25.

Kata Kunci : safety, arc flash, incident energy, arc flash boundary, personal protective equipment