Laporkan Masalah

OPTIMASI DAYA LASER PADA SPEKTROMETER FOTOAKUSTIK LASER CO2 KONFIGURASI INTRAKAVITAS DAN APLIKASINYA DALAM PENGUKURAN KONSENTRASI GAS ETILEN PADA GAS HEMBUS RELAWAN PEMAKAN GORENGAN

MAMILA ZIYYIT TUQO, Dr. Mitrayana

2015 | Tesis | S2 Ilmu Fisika

Telah dilakukan optimasi daya laser pada spektrometer fotoakustik laser CO2 konfigurasi intrakavitas. Diperoleh 4 grup garis laser dengan daya tertinggi sebesar 37 W pada komposisi gas medium aktif He:N2:CO2 adalah 30:70:55. Diperoleh garis serapan laser tertinggi untuk gas etilen standar adalah 10P14 dan didapatkan batas deteksi terendah (BDT) gas etilen sebesar 57,1 �¬+ 0,4 ppb (part per billion). Selanjutnya spektrometer fotoakustik laser CO2 diaplikasikan dalam pengukuran konsentrasi gas etilen (C2H4) pada gas hembus relawan pemakan gorengan. Sampel divariasi terhadap usia dan gender. Berdasarkan penelitian, untuk relawan berusia <15 tahun, konsentrasi gas etilen tertinggi adalah sebesar 5,570 �± 0,002 ppm pada saat 30 menit setelah memakan gorengan. Untuk relawan berusia 15-30 tahun, konsentrasi gas etilen tertinggi sebesar 5,644�±0,002 ppm pada saat 120 menit setelah memakan gorengan. Sedangkan untuk relawan berusia >30 tahun, konsentrasi gas etilen tertinggi sebesar 6,866�±0,002 ppm pada saat 120 menit setelah memakan gorengan. Hasil penelitian menunjukkan bahwa memakan gorengan mempengaruhi peningkatan konsentrasi etilen di dalam tubuh serta terdapat perbedaan konsentrasi gas etilen terhadap variasi usia karena adanya perbedaan sistem metabolisme di dalam tubuh manusia.

The laser power optimization of CO2 laser photoacoustic spectrometer intracavity configuration has been conducted. It was generated 4 laser group and highest power was obtained at 37 W with medium active gas composition He:N2:CO2 was 30:70:55. The highest laser absorption line of standard ethylene gas was acquired at 10P14 and lowest detection limit was obtained at 57,1�¬+0,4 ppb (part per billion). Furthermore, CO2 laser photoacoustic spectroscopy applied to the measuring of ethylene gas (C2H4) in fried foods consumer breath. Samples were variated for ages and genders. Based on research, for <15 years volunteers, the highest concentration of ethylene gas was 5,570�±0,002 ppm during 30 minutes after eating fried foods. For volunteers aged 15-30 years, the highest concentration of ethylene gas was 5,644�±0,002 ppm during 120 minutes after eating fried foods. For volunteers aged> 30 years, the highest concentration of ethylene was 6,866�±0,002 ppm during 120 minutes after eating fried foods. The result showed that eating fried food influenced the increase of ethylene concentration in body then there was difference of ethylene gas concentration to the age variation due to the difference metabolism in human body.

Kata Kunci : Spektrometer fotoakustik laser CO2, pemakan gorengan, gas etilen.

  1. S2-2015-351237-abstract.pdf  
  2. S2-2015-351237-bibliography.pdf  
  3. S2-2015-351237-tableofcontent.pdf  
  4. S2-2015-351237-title.pdf