Petir adalah gangguan alam yang sering terjadi di Indonesia. Maka dari itu bangunan-bangunan di Indonesia memiliki resiko lebih besar mengalami kerusakan akibat terkena sambaran petir. Intensitas petir yang tinggi di Provinsi Kalimantan Timur, yakni 172 hari guruh per tahun merupakan ancaman serius bagi struktur T/G Building Utilities Module II di PT Badak NGL. Menyadari kondisi tersebut, perlu dilakukan evaluasi sistem proteksi petir sehingga dapat bekerja dengan efektif dan efisien dan tidak mengganggu proses produksi di PT Badak NGL. Peningkatan performa sistem terhadap gangguan akibat petir dapat dilakukan dengan mengevaluasi pemasangan terminal udara, penghantar turun, sistem pentanahan dan sistem proteksi petir internal. Dengan analisis dengan metode collection volume ditemukan bahwa pemasangan terminal udara pada struktur bangunan dapat memberikan perlindungan yang baik pada bangunan. Metode penentuan jumlah terminal udara dengan metode collection volume jauh lebih efisien dibandingkan dengan metode sudut. Menurut perhitungan load corrosion (IEC 61024) petir dapat mempengaruhi down conductor, sehingga disarankan untuk melakukan pengecekan berdasarkan perhitungan volume kerusakan. Sistem pentanahan di struktur sudah memiliki nilai resistan yang baik menurut NFPA. Dari segi instalasi, sistem proteksi petir internal pada struktur bangunan sudah memenuhi standar IEEE-142-2007.

Lightning is a natural phenomenon that often occurs in Indonesia. Thus, buildings in Indonesia have a greater risk of damage due to exposure to lightning strikes. A high lightning intensity in East Kalimantan, which is 172 days of thunder per year is going to be a serious threat to the T/G Building Utilities Module II in PT Badak NGL. Aware of this situation, an evaluation needs to be done so that the lightning protection system can works effectively and efficiently and won�t interfere with the production process in PT Badak NGL. To Improve the performance of the lightning protection system from lightning can be done by evaluating the installation of air terminals, down conductors, earthing system and internal lightning protection system. With collection volume method analysis, it was found that the installation of air terminal (lightning rod) on the building will give a good protection to the building itself. The determination on air terminal numbers with collection volume method also far more eficient compared to protection degree method. According to load corrosion calculation (IEC 61024) lightning could affect the down conductor, so it's recommended to do inspections / maintenance based on damaged volume calculation. Grounding system on the structure already have great resistance value according to NFPA. From observation of the installation, the building has a proper internal lightning protection system according to IEEE-142-2007.

Kata Kunci : petir, penangkal petir, terminal udara, penghantar turun, sistem pentanahan, arrester, lightning, lightning protection system, air terminal, down conductor, grounding system, arresters


    Tidak tersedia file untuk ditampilkan ke publik.