PENGUKURAN KONSENTRASI LARUTAN MENGGUNAKAN TRANSDUSER KAPASITIF

Muhammad Hidayatullah, Dr. Kuwat Triyana

2014 | Tesis | S2 Ilmu Fisika

Telah dilakukan pengukuran konsentrasi larutan menggunakan transduser kapasitif yang bekerja berdasarkan fenomena electrical capacitive tomography (ECT). Sebelum digunakan, transduser kapasitif diverifikasi berdasarkan ASTM D.1076-02 terhadap sampel larutan getah lateks oleh Laboratorium Penguji Balai Penelitian Teknologi Karet Bogor. Dua jenis larutan yang diukur konsentrasinya dalam penelitian ini adalah larutan gula dan larutan sodium hidroksida (NaOH), keduanya dengan pelarut air pada berbagai variasi konsentrasi. Larutan gula mewakili bahan non-elektrolit, sedangkan NaOH mewakili bahan elektrolit. Dalam pelaksanaan pengukuran konsentrasi larutan, dibutuhkan konsentrasi tertinggi sebagai referensi yang dalam hal ini digunakan konsentrasi 95% untuk larutan gula. Sebagai pembanding juga digunakan konsentrasi referensi 80%. Untul larutan gula, pada saat digunakan konsentrasi referensi 95%, diperoleh hubungan linier antara konsentrasi larutan uji dengan konsentrasi terukur dengan nilai koefisien korelasi sebesar 0,999. Nilai koefisien korelasi menurun menjadi 0,996 pada saat konsentrasi referensi adalah 80%. Sementara itu, untuk larutan NaOH digunakan konsentrasi referensi 80%, sehingga diperoleh nilai koefisien korelasi sebesar 0,999. Dengan demikian dapat disimpulkan bahwa transduser kapasitif mempunyai potensi yang tinggi sebagai alat alternatif untuk mengukur konsentrasi larutan dengan cepat tanpa preparasi sampel.

Concentration of water based solutions has been measured by using a capacitive transducer which works based on the phenomenon of electrical capacitive tomography (ECT). Before being used, the capacitive transducer was verified by ASTM D.1076-02 standard to the latex solution by Laboratorium Penguji Balai Penelitian Teknologi Karet Bogor. Two types of solutions were measured in this study, i.e. the concentration of sugar solution and sodium hydroxide (NaOH) solution at various concentrations. The sugar solution represents a non-electrolyte samples, while the NaOH solution represents an electrolyte samples. In the implementation of measurements, the highest concentration was employed as a reference. In this case, we used the reference concentrations of 95% for the sugar solution. For purpose of comparison we also used 80% of the reference concentration of sugar solution. By using the reference concentration of 95%, we found a linear relationship between the concentration of the test solution and the measured concentration by the correlation coefficient of 0.999. Correlation coefficient decreased to 0.996 when the reference concentration was 80%. Meanwhile for the NaOH solution, the correlation coefficient was found to be 0.999 when the reference concentration was 80%. It can be concluded that the capacitive transducer shows high potential for measuring concentration of a solution rapidly without any sample preparation.

Kata Kunci : transduser kapasitif, electrical capacitive tomography, konsentrasi larutan.


    Tidak tersedia file untuk ditampilkan ke publik.