PENGARUH SUSUNAN KONFIGURASI MICROBUBBLE GENERATOR TERHADAP KADAR DISSOLVED OXYGEN DAN ANALISIS KECENDERUNGAN WAKTU KERJA EFEKTIF POMPA PADA SISTEM PENGOLAHAN AIR LIMBAH
NANDA TITIS PRABA KUSUMA, Dr. Ir. Suhanan, DEA.
2014 | Skripsi | TEKNIK MESINPerkembangan industri yang pesat cenderung memberikan dampak buruk bagi lingkungan apabila tidak disertai dengan pengelolaan limbah buang pasca industri. Air sebagai salah satu limbah industri harus tetap terjaga kebersihannya karena memiliki peranan penting bagi kehidupan setiap makhluk hidup. Lebih lagi meningkatnya pertumbuhan penduduk menjadi paradoks tersendiri bagi kualitas ketersediaan air bersih. Pada penelitian ini dilakukan pengamatan tentang pengaruh susunan konfigurasi microbubble generator (MBG) terhadap kadar DO (Dissolved Oxygen) dan analisis kecenderungan waktu kerja efektf pompa. Tipe microbubble generator yang digunakan adalah tipe orifice dan porous pipe. Penelitian ini dilaksanakan di kolam Instalasi Pengolahan Air Limbah (IPAL) berukuran 3 m x 3 m x 1 m dengan 3 macam konfigurasi dan 8 buah MBG pada setiap konfigurasinya. Digunakan kondisi QL 16 m3/jam dan QG 0,03 m3/jam dengan sistem pompa 30 menit on dan 45 menit off. 4 DO meter diletakkan pada 4 titik tertentu untuk dilakukan pengukuran mengenai kadar DO pada air. Tujuan dari penelitian ini adalah untuk mengetahui kadar DO yang tersebar di air agar dapat memenuhi BOD (Biological Oxygen Demand) yang dibutuhkan oleh bakteri aerob untuk tetap hidup. Bakteri tersebut nantinya akan bertugas mengurangi kadar COD (Chemical Oxygen Demand) pada air limbah. Hasil penelitian menunjukkan bahwa setiap konfigurasi mampu menghasilkan nilai DO yang merata pada seluruh area kolam. Susunan konfigurasi dengan kecenderungan terjadi bubble coalescence yang rendah akan meningkatkan nilai kadar DO dan konfigurasi III adalah konfigurasi dengan kadar DO paling optimal yaitu 7,85 mg/L sehingga konfigurasi tersebut dapat diadopsi sebagai alternatif pengolahan air limbah industri.
Rapid industrial development tends to have a negative impact for environtment if not accompanied by post-industrial waste management. Water as one of the industrial waste must remain kept clean because it has an important role for the life of every organism. Moreover, the increasing population growth becomes a paradox for the quality of the availability of clean water. In this research, observation of the effects of microbubble generator (MBG) configuration arrangement on DO (Dissolved Oxygen) levels and effective working time trend analysis of the pump on wastewater treatment system. Types of microbubble generator used are the orifice and porous pipe. This research was conducted in a Wastewater Treatment Plant (WTP) measuring 3 m x 3 m x 1 m with 3 kinds of configurations and 8 pieces of MBG on each configuration. Applying condition of QL 16 m3/hr and QG 0.5 L/min with a pump system 30 minutes on and 45 minutes off. 4 DO meter placed at 4 particular points for the measurement of DO levels in the water. The purpose of this research was to determine levels of scattered DO in the water in order to meet the BOD (Biological Oxygen Demand) required by aerobic bacteria to keep them alive. Bacteria will be in charge of reducing the levels of COD (Chemical Oxygen Demand) in the wastewater. The results showed that each configuration is capable of producing a uniform value of DO in the entire pool area. The arrangement of the configuration with the tendency to bubble coalescence low will increase the value of DO levels and configuration III is the most optimal DO levels of 7.85 mg/L so that the configuration can be adopted as an alternative to industrial wastewater treatment.
Kata Kunci : microbubble, microbubble generator, konfigurasi, Dissolved Oxygen, bubble coalescence, waktu kerja efektif pompa