EVALUASI KINERJA GEDUNG KANTOR PUSAT FAKULTAS TEKNIK (KPFT) UNIVERSITAS GADJAH MADA TERHADAP PENGARUH GEMPA DENGAN ANALISIS PUSHOVER

ABDA YANUAR AKHSAN, Prof. Ir. Iman Satyarno, M.E., Ph.D.

2014 | Tesis | S2 Teknik Sipil

Gempa bumi merupakan bencana alam yang seringkali mengakibatkan banyak korban jiwa dan kerusakan pada bangunan, walaupun hanya terjadi selama beberapa detik. Gedung KPFT UGM adalah bangunan beton bertulang yang dibangun pada tahun 1985 yang terletak di kota Yogyakarta. Pada 27 Mei 2006 terjadi gempa di Yogyakarta dan Gedung KPFT UGM mengalami beberapa kerusakan pada elemen struktur gedung. Oleh karena itu perlu dilakukan penelitian untuk mengevaluasi perilaku dan level kinerja dari struktur gedung KPFT UGM. Evaluasi dilakukan dengan Rapid Visual Screening menurut FEMA 154 (2002). Evaluasi lebih rinci berdasarkan FEMA 310 (1998). Ada tiga tahap evaluasi pada FEMA 310, tahap 1 (Screening), tahap 2 (tahap evalusi peninjauan Design Capacity Ratio), tahap 3 (evaluasi lebih rinci/Pushover). Dalam tahap 2 digunakan Analisis Beban Statik Ekivalen untuk prosedur statik linier dan Analisis Respon Spektrum.Prosedur analisis dengan pemodelan portal terbuka. Pembebanan gempa mengacu pada SNI 03-1726-2002 dan SNI 03-1726-2011. Kekuatan elemen struktur dihitung dengan SNI 2847-2002 dan Response 2000. Evaluasi tahap 3 dilakukan dengan analisis pushover untuk prosedur nonlinier pada wilayah gempa 3 dan wilayah gempa 4 tanah sedang SNI 03-1726-2002 dan wilayah Yogyakarta dengan SNI 03-1726-2011. Titik kinerja (performance point) ditentukan dengan Metode Spektrum Kapasitas berdasarkan ATC–40 (1996) yang sudah built-in dalam SAP 2000 versi 11. Level kinerja struktur ditentukan melalui kriteria storey drift yang diisyaratkan oleh FEMA 356 (2000), FEMA 302 (1997) dan ATC-40 (1996). Dari hasil penelitian diperoleh bahwa Titik kinerja struktur gedung KPFT UGM sesuai ATC 40 berdasarkan storey drift untuk atap dan lantai 3 Immediate Occupancy, lantai 2 Life Safety, dan lantai dasar Damage Control. Sesuai FEMA 356 dan FEMA 302 berdasarkan storey drift untuk atap dan lantai 3 Immediate Occupancy, lantai 2 Collapse, dan lantai dasar Life Safety. Percepatan puncak batuan dasar gedung KPFT UGM untuk arah Y (utaraselatan) memenuhi persyaratan yang ditetapkan oleh SNI-03-1726-2002 wilayah gempa 3 (150 gal) dan SNI-03-1726-2002 wilayah gempa 4 (200 gal), berdasarkan SNI-03-1726-2011 wilayah Yogyakarta (499 gal) tidak memenuhi persyaratan dan untuk arah X (barat-timur) memenuhi persyaratan yang ditetapkan oleh SNI-03-1726-2002 wilayah gempa 3 (150 gal), berdasarkan SNI- 03-1726-2002 wilayah gempa 4 (200 gal) dan berdasarkan SNI-03-1726-2011 wilayah Yogyakarta (499 gal) tidak memenuhi persyaratan.

Earthquakes are natural disasters that often resulted in many casualties and damage to buildings, although only occurs for a few seconds only. KPFT UGM building is a reinforced concrete building built in 1985 is located in the city of Yogyakarta. On May 27th, 2006 occurred the earthquake in Yogyakarta and KPFT UGM building suffered some damage in the structural elements building. Therefore, conducted a study to evaluate the behavior and the performance level of the building structure KPFT UGM. Evaluation is done by Rapid Visual Screening according to FEMA 154 (2002). More detailed evaluation is based on FEMA 310 (1998). There are three stages of evaluation on FEMA 310, Stage 1 (Screening), Stage 2 (stage evaluation review of Design Capacity Ratio), Stage 3 (more detailed evaluation / Pushover). In Stage 2 is used Static Equivalent Load Analysis for linear static procedures and Response Analysis Spektrum.Procedure with an open portal modeling analysis. Earthquake loading refers to SNI 03-1726-2002 and SNI 03-1726-2011. Strength of structural elements calculated by SNI 2847-2002 and Response-2000. Stage 3 evaluation is done with a pushover analysis for nonlinear procedures in seismic zone 3 and seismic zone 4 land being SNI 03-1726-2002 and SNI 03-1726-2011 Yogyakarta region. Performance point is determined by the Capacity Spectrum Method based on ATC-40 (1996), which has been built-in in the SAP 2000 version 11. Levels of the performance are determined by the storey drift structure criteria implied by FEMA 356 (2000), FEMA 302 (1997) and ATC-40 (1996). The result showed that the performance point of the KPFT UGM building structure in accordance ATC 40 based storey drift to the roof and 3rd floor are Immediate Occupancy, 2nd floor is Life Safety, and the ground floor is Damage Control for. As per FEMA 356 and FEMA 302 based storey drift to the roof and 3rd floor are Immediate Occupancy, 2nd floor is Collapse, and the ground floor is Life Safety. Acceleration peak bedrock for KPFT UGM building Y-direction (northsouth) meet the requirements set by the SNI-03-1726-2002 seismic zone 3 (150 gal) and SNI-03-1726-2002 seismic zone 4 (200 gal), by SNI-03-1726-2011 Yogyakarta region (499 gal) does not meet the requirements and to the Xdirection (east-west) meets the requirements set by the SNI-03-1726-2002 seismic zone 3 (150 gal), based on SNI-03 -1726-2002 seismic zone 4 (200 gal) and based on SNI-03-1726-2011 Yogyakarta (499 gal) does not meet the requirements.

Kata Kunci : analisis pushover, performance point, metode spektrum kapasitas, drift ratio, level kinerja


    Tidak tersedia file untuk ditampilkan ke publik.