STUDI ANALISIS GANGGUAN TRANSFORMATOR DISTRIBUSI PADA JARINGAN DISTRIBUSI 20 KV Di PT. PLN (Persero) Distribusi Jawa Barat dan Banten Area Pelayanan dan Jaringan (APJ) Karawang KARAWANG – JAWA BARAT
JOHANES EXSHY, Ir. Rizal
2013 | Tugas Akhir | D3 TEKNIK ELEKTROTransformator distribusi merupakan jantung dari jaringan distribusi tenaga listrik 20 kV. Transformator distribusi diharapkan bekerja terus-menerus untuk mensuplai tenaga listrik ke pelanggan. Timbulnya gangguan pada transformator distribusi mengakibatkan kerusakan pada trafo dan terputusnya penyaluran tenaga listrik ke pelanggan. Gangguan pada transformator distribusi dapat diakibatkan terjadinya hubung singkat eksternal, kegagalan isolasi, akibat petir, kegagalan proteksi, kelemahan tap changer, kurangnya pemeliharaan, kesalahan operasional, proses penuaan, kerusakan atau kebocoran packing, kebocoran pada bushing dan penyebab gangguan lainnya. Studi kasus pada jaringan distribusi 20 kV di PT. PLN (Persero) Karawang, selama semester pertama tahun 2013, menunjukkan tingginya gangguan yang terjadi pada transformator distribusi. Gangguan karena hubung singkat 6,25 %, karena kegagalan isolasi 31,25 %, akibat petir 37,5 %, karena kegagalan proteksi 4,17 %, karena kurangya pemeliharaan 2,08 %, karena kesalahan operasional 4,17 %, karena proses penuaan 10,42 %, karena kebocoran bushing 2,08 % dan karena penyebab lain 2,08 %. Terlihat bahwa gangguan terbanyak adalah akibat petir, yaitu sebanyak 37,5 %.
Distribution transformer is the heart of the power distribution network of 20 kV. Distribution transformers are expected to work continuously to supply electricity to customers. Interference with the distribution transformer resulting in damage to the transformer and the electrical power supply interruption to customers. Disturbances in the distribution transformer can be caused by the occurrence of an external short circuit, failure of isolation, due to lightning, protection failure, tap changer weakness, lack of maintenance, operational errors, the process of aging, damage or packing leaks, leaks in the bushing and other cause of disorders. A case study on 20 kV distribution network in PT . PLN ( Persero ) Karawang, during the first half of 2013, indicating a high disturbance occurs in distribution transformers. Disorders due to short circuit 6.25 %, due to insulation failure 31.25 %, 37.5 % due to lightning, because of protection failure 4.17 %, due to lack of maintenance 2.08 %, 4.17 % due to operational errors, because of the process aging 10.42 %, 2.08 % due to leakage bushing and 2.08 % from other causes. It is seen that the most disorders are due to lightning, as many as 37.5 %.
Kata Kunci : transformator distribusi, gangguan transformator distribusi.