Laporkan Masalah

SIMULASI PENGGANTIAN KACA DAN PENGGUNAAN VEGETASI SEBAGAI SUN SHADING TERHADAP SOLAR EXPOSURE GEDUNG PUSAT UNIVERSITAS GADJAH MADA

MUHAMMAD FITRA ARIEF, Dr.Eng. Mohammad Kholid Ridwan, S.T.,M.Sc

2013 | Skripsi | FISIKA TEKNIK

Gedung Pusat Universitas Gadjah Mada (UGM) merupakan salah satu bangunan cagar budaya di Daerah Istimewa Yogyakarta (DIY). Bangunan Gedung Pusat UGM memiliki empat sisi. Dengan adanya sisi-sisi tersebut dapat mempengaruhi intensitas penyinaran matahari yang diterima oleh tiap sisinya. Intensitas penyinaran matahari akan berdampak pada nilai solar exposure yang dapat diterima, dimana nilai solar exposure tersebut dapat dijadikan acuan guna mengetahui tingkat kenyamanan termal ataupun pencahayaan dalam suatu ruangan. Perhitungan solar exposure juga dipengaruhi oleh material penyusun bangunan, terutama material tembus cahaya, misalnya kaca. Dengan adanya variasi material yang dipakai, maka nilai solar exposure yang dihasilkan juga akan bervariasi. Adanya penambahan vegetasi pada bangunan juga mempengaruhi nilai solar exposure yang dapat diterima oleh bangunan, dikarenakan vegetasi mampu mengabsorbsi radiasi matahari. Penelitian ini bermaksud untuk mengukur solar exposure yang diterima oleh Gedung Pusat UGM dengan menggunakan metode simulasi pada Ecotect. Hasil dari penelitian ini adalah nilai total absorbsi radiasi matahari di Gedung Pusat UGM dalam satu tahun sebesar 65.700 Wh/m 2 , sedangkan nilai total transmisi radiasi mataharinya sebesar 531.593 Wh/m 2 . Hasil lainnya yaitu dengan penambahan vegetasi sebagai sun shading mampu meningkatkan tingkat absorbsi radiasi matahari sebesar 132,28% dari kondisi awal.

Central building Universitas Gadjah Mada (UGM) is one of the heritage buildings in the Special Region of Yogyakarta (DIY). Central building of UGM has four sides. The sides can affect the intensity of solar radiation received by each side. Intensity of solar radiation will have an impact on the value of solar exposure, where the value of solar exposure can be used as a reference to determine the level of thermal comfort or lighting comfort inside a room. Calculation of solar exposure also influenced by the constituent materials of the building, especially the translucent material, such as glass. With the variation of the material used, the value of solar exposure will also vary. The addition of vegetation on buildings also affects the value of solar exposure that is accepted by the building, because the vegetation is able to absorb solar radiation. This study intends to measure the solar exposure received by the central building of UGM using simulation in Ecotect. The results of this study is the total value of the absorption of solar radiation in the central building of UGM in one year amounted to 65,700 Wh/m 2 , while the total value of the transmission of sun radiation at 531,593 Wh/m 2 . Another result is the addition of vegetation as a sun shading can increase the level of absorption of solar radiation at 132.28% of the initial conditions.

Kata Kunci : Gedung Pusat UGM, solar exposure, kaca, tanaman vegetasi, Ecotect, absorbsi, transmisi


    Tidak tersedia file untuk ditampilkan ke publik.