PENGARUH VARIASI WAKTU STERILISASI DENGAN SINAR ULTRA VIOLET TERHADAP ANGKA KUMAN UDARA RUANG OPERASI RSUD BRIGJEND. H. HASAN BASRY KANDANGAN PROVINSI KALIMANTAN SELATAN

NINA FEBRIYANTI, Prof. Dr. dr. Adi Heru Sutomo, M.Sc, D.CN.

2013 | Tesis | S2 Ilmu Kesehatan Masyarakat

Latar Belakang : Rumah sakit sebagai institusi pelayanan medis tidak mungkin lepas dari keberadaan sejumlah mikroba patogen. Infeksi nosokomial adalah salah satu penyebab meningkatnya angka kesakitan dan kematian di rumah sakit. Sterilisasi sinar ultra violet merupakan salah satu upaya yang dapat dilakukan untuk menurunkan angka kuman udara di ruang operasi. Persyaratan angka kuman udara ruang operasi menurut Keputusan Menteri Kesehatan RI No. 1204/Menkes/SK/X/2004 tentang Persyaratan Kesehatan Lingkungan Rumah Sakit yaitu maksimal 10 CFU/m3. Tujuan : Untuk mengetahui waktu sterilisasi dengan sinar ultra violet yang paling efektif dalam penurunan angka kuman udara di ruang operasi RSUD Brigjend. H. Hasan Basry Kandangan. Metode penelitian : Jenis penelitian adalah eksperimen semu dengan design one group pre and post test, lokasi di ruang operasi RSUD Brigjend. H.Hasan Basry Kandangan. Pengambilan sampel dilakukan sebelum sterilisasi dengan sinar UV selama 0,5 jam, 1 jam, 1,5 jam, 2 jam dan sesudah sterilisasi dengan sinar UV selama 0,5 jam, 1 jam, 1,5 jam dan 2 jam. Variabel penelitian terdiri dari variabel bebas yaitu variasi waktu sterilisasi dengan sinar UV, variabel terikat yaitu angka kuman udara dan variabel luar yaitu suhu, kelembaban, pencahayaan. Analisis data menggunakan uji statistik Paired T Test, Pearson Correlation dan analisis Regresi Linier dengan α = 0,05. Hasil : Hasil penelitian menunjukkan ada pengaruh variasi waktu sterilisasi sinar UV terhadap angka kuman udara di ruang operasi RSUD Brigjend. H. Hasan Basry Kandangan, dimana hasil analisis statistik dengan Paired T Test menunjukkan perbedaan rata-rata jumlah angka kuman udara sebelum dan sesudah sterilisasi dengan sinar UV (p= 0,000, p= 0,001, p= 0,000 dan p= 0,000). Kesimpulan : Ada pengaruh variasi waktu sterilisasi sinar UV terhadap angka kuman udara di ruang operasi RSUD Brigjend. H. Hasan Basry Kandangan. Waktu sterilisasi dengan sinar UV yang paling efektif dalam penurunan angka kuman udara di ruang operasi RSUD Brigjend. H. Hasan Basry Kandangan adalah selama 2 jam dengan jumlah lampu UV sebanyak 4 buah, masing-masing kekuatan lampu UV sebesar 30 watt.

Background: Hospital as a medical care institution may not be separated from the presence of a number of microbial pathogens. Nosocomial infections are one of the causes of increased morbidity and mortality in hospitals. UV sterilization is an effort that can be done to reduce the microbial air count in the operating room. The terms of the microbial air count in the operating room according to the Decree of the Minister of Health of Indonesia No.1204/Menkes/SK/X/2004 about requirements of health of hospital environment to a maximum of 10 CFU/m3. Objective: To determine the time of sterilization by UV rays which is the most effective in reducing the number of aerial germs in the operating room of Local General Hospital Brigjend. H. Hasan Basry Kandangan. Methods: The research was a quasi-experiment with one group pre and post test design, located in the operating room of Local General Hospital Brigjend. H.Hasan Basry Kandangan. Sampling was done before sterilization with UV rays for 0.5 hours, 1 hour, 1.5 hours, 2 hours and after sterilization with UV rays for 0.5 hours, 1 hour, 1.5 hours and 2 hours. Variables consisted of the independent variables with the time variation of the sterilization by UV rays, the dependent variable that is the microbial air count and the outside variables that are temperature, humidity, and lighting. Data analysis using statistical test Paired T Test, Pearson Correlation and Linear Regression analysis with α = 0.05. Results: The results showed there was effect of the time variation of sterilization by UV rays of the microbial air count in the operating room of Local General Hospital Brigjend. H. Hasan Basry Kandangan, where the results of statistical analysis with Paired T Test showed differences in the average number of microbial air count before and after sterilization by UV rays (p = 0.000, p = 0.001, p = 0.000 and p = 0.000). Conclusion:. There was the influence of the time variation of sterilization by UV rays on the microbial air count in the operating room of Local General Hospital Brigjend. H. Hasan Basry Kandangan. The most effective time sterilization by UV rays in decreasing the microbial air count in the operating room of Local General Hospital Brigjend. H. Hasan Basry Kandangan is for 2 hours with a UV lamp amount of 4 pieces, each UV lamp power of 30 watts.

Kata Kunci : Ruang Operasi, Sterilisasi Sinar Ultra Violet, Angka Kuman Udara


    Tidak tersedia file untuk ditampilkan ke publik.