PERANCANGAN PEMBUATAN ISOLATOR BERBAHAN AIR MURNI UNTUK PENGUJIAN TEGANGAN TINGGI
WAHYU DWI PRASETIYO, Dr. Eng. Suharyanto, S.T., M.Eng.
2013 | Skripsi | TEKNIK ELEKTROPengujian tegangan tinggi bertujuan untuk meneliti sifat-sifat listrik dielektrik menyangkut kualitas sistem isolasi peralatan tenaga, yaitu memeriksa kualitas peralatan sebelum terpasang ataupun setelah operasi, untuk menghindarkan kerugian bagi pemakai peralatan dan mengurangi kerugian semasa pemeliharaannya. Untuk itu diperlukan berbagai alat pengujian yang harus mampu menahan tegangan tinggi selama pengujian, salah satunya yaitu isolator berbahan air murni. Penelitian ini bertujuan untuk mengetahui bagaimana pengaruh jarak antar elektroda dan berbagai jenis elektroda terhadap kemampuan isolasi dari air murni, watak isolator air murni ketika dikenakan tegangan impuls dan kemampuan isolator air murni dalam menahan arus bocor DC dan arus bocor AC. Penelitian diawali dengan mengukur besar resistans isolator air murni dengan pengaruh jarak antar elektroda dan berbagai jenis elektroda untuk mengetahui seberapa besar tegangan yang bisa dikenakan selama pengujian. Pengujian impuls dilakukan dengan tegangan uji sebesar 66,88 kV dengan variabel jarak antar elektroda hingga terjadi busur api. Selanjutnya dilakukan pengujian arus bocor DC dan AC dengan tegangan yang dikenakan yaitu sebesar 1 kV, 2 kV, 3 kV dan 5 kV dan tiap pengujiannya dilakukan sebanyak 3 kali dengan durasi 5 detik. Berdasarkan hasil pengujian diketahui isolator air murni mampu menahan tegangan impuls hingga tegangan 66,88 kV dipengaruhi oleh bentuk ujung permukaan elektroda dan jarak antar elektroda. Pada pengujian arus bocor DC, terjadi proses elektrolisis yang menyebabkan memburuknya kualitas isolasi air murni dan juga dipengaruhi oleh luas penampang elektroda. Dimana semakin besar luas penampang elektroda maka semakin besar arus bocor DC yang dapat mengalir. Sedangkan pada pengujian arus bocor AC, jenis elektroda mempengaruhi besar arus yang mengalir akibat banyaknya endapan yang terbentuk.
High voltage testing aims to investigate the electrical properties of dielectric insulation system on the quality of power equipment, the quality checking equipment installed before or after operation, to avoid any harm to the user and reduce losses during equipment maintenance. It required a variety of testing tools that should be able to withstand high voltages during the test, one of which is an insulator made from purified water. This study aims to determine how the effect of the distance between the electrodes and different types of electrodes on the insulating ability of pure water, pure water insulator character when worn and the impulse voltage capability of pure water in the hold insulator leakage current DC and AC leakage current. The study begins by measuring the resistance of the insulator pure water with the distance between the electrodes and the effect of different types of electrodes to know how much voltage that can be worn during the test . Testing is done by impulse test voltage of 66.88 kV with a variable distance between the electrodes until an arc. Further testing of leakage current with DC and AC voltage applied is equal to 1 kV, 2 kV, 3 kV and 5 kV and each test performed 3 times with a duration of 5 seconds. Based on the test results are known insulator pure water is able to withstand the impulse voltage to 66.88 kV voltage is affected by the shape of the tip electrode surface and the distance between the electrodes. In testing the DC leakage current, electrolysis reactions that cause deterioration of insulation quality pure water and is also affected by the cross-sectional area electrodes. Where the greater cross-sectional area, the greater the electrode DC leakage current can flow. While in testing AC leakage current, the type of the electrode affects the current flow due to the large precipitate formed.
Kata Kunci : isolator, air murni, pengujian impuls, arus bocor, elektrolisis