ANALISIS CITRA UNTUK ANGIOGRAFI DIGITAL SINAR X DENGAN MEDIA KONTRAS : KASUS VENTRIKEL SEPTAL DEFECT (VSD)

SRI WAHYUNI, Dr. Gede Bayu Suparta

2013 | Tesis | S2 Ilmu Fisika

Telah dilakukan penelitian analisis citra pada Angiografi sinar-x. Pada penelitian ini analisis citra angiografi dilakukan dengan tindakan penyadapan atau kateterisasi jantung menggunakan media kontras pada pasien penderita Ventrikel Septal Defect (VSD). Pengambilan citra menggunakan perangkat lunak PMSDVIEW sedangkan analisis citra menggunakan perangkat lunak ImageJ. Analisis citra meliputi pengukuran sistole dan diastole jantung, korelasi kecepatan memompa jantung terhadap sumber tegangan, karakteristik media kontras serta pengukuran defek pada septal ventrikel. Dari hasil penelitian diperoleh bahwa ukuran jantung saat sistole yaitu 61 ± 1 mm dan saat diastole yaitu 51 ± 1 mm. Perubahan ukuran jantung dari diastole ke sistole sebesar 10 ± 1 mm dengan persentase 19%. Berdasarkan citra digital kecepatan gerak jantung terhadap vasiasi sumber tegangan 75,3 kV sebesar 2114 ± 51 mm/ms, sumber tegangan 71,6 kV dengan kecepatan gerak jantung sebesar 229 ± 11 mm/ms, tegangan 76,1 kV kecepatannya 1325 ± 36 mm/ms, pada tegangan 75,3 kV dengan kecepatannya 1646 ± 46 mm/ms dengan lama penyinaran 4 ms. Pada karakteristik penyebaran media kontras dalam ventrikel jantung dipengaruhi oleh waktu injeksi dan daerah yang dilalui media kontras. Diameter defek pada shunt (kebocoran) pasien penderia VSD jantung yang terukur sebesar yaitu 3,63 ± 0,19 mm.

Image analysis research on the x-ray angiography has been done. In this research, angiographyimage analysis performed by cardiac catheterization use contrast media in patients with Ventricular Septal Defect (VSD). Image retrieval using PMSDVIEW software while the image analysis using software ImageJ. Image analysis include measurement of systolic and diastolic heart, heart pumping velocity correlation to the voltage source, the characteristics of contrast media as well as measurements of ventricular septal defect. The result showed that the size of the heart at systole is 61 ± 1 mm and at diastole at 51 ± 1 mm. Changes in heart size from diastole to systole by 10 ± 1 mm with percentage of 19%. Based on the digital image of the velocity of the heart to the 75.3 kV voltage source variations at 2114 ± 51 mm / ms, source voltage of 71.6 kV with a heart as big as the velocity of 229 ± 11 mm / ms, voltage of 76.1 kV speed is 1325 ± 36 mm / ms, at a voltage of 75.3 kV with velocity 1646 ± 46 mm / ms to 4 ms long irradiation. On the characteristics of the spread of contrast medium in cardiac ventricle affected by the time of injection and the area through which the contrast medium. Diameter defect shunt (leakage) penderia VSD patients at the heart of the measured 3.63 ± 0.19 mm.

Kata Kunci : Kardiovaskular, Media kontras, Angiografi, Citra Digital


    Tidak tersedia file untuk ditampilkan ke publik.