Laporkan Masalah

PEMANFAATAN RADIOGRAFI DIGITAL UNTUK ANALISIS KUALITAS BAHAN TANAH LIAT KERAJINAN KERAMIK DARI KASONGAN BANTUL YOGYAKARTA

HERLINA KURNIASARI, Dr. Gede Bayu Suparta

2013 | Tesis | S2 Ilmu Fisika

Telah dilakukan penelitian untuk menganalisa kualitas bahan tanah liat menggunakan teknik radiografi digital sinar-X. Pengujian dilakukan terhadap tiga jenis tanah liat earthenware abu-abu, earthenware merah, dan stoneware yang merupakan hasil proses pengayakan dengan nomor ayakan 40, 60, 80, 100, dan 120 mesh. Parameter kualitas bahan tanah liat pada sistem radiografi digital sinar-X diukur dengan cara menghitung koefisien serapan linear (μ) dan persentase susut kering tanah liat. Tanah liat earthenware abu-abu tanpa pengayakan memiliki koefisien serapan linear 0,462 cm-1 dan susut kering 3,6 %. Setelah melalui proses pengayakan tanah liat earthenware abu-abu memiliki koefisien serapan linear yang praktis sama dengan tanah tanpa pengayakan dan memiliki susut kering 4,5% - 7,9 %. Tanah liat earthenware merah tanpa pengayakan memiliki koefisien serapan linear 0,482 cm-1 dan susut kering 6,1 %. Setelah melalui proses pengayakan tanah liat earthenware merah memiliki koefisien serapan linear yang praktis sama dengan tanah tanpa pengayakan dan memiliki susut kering 7,0 % - 10,4 %. Tanah liat stoneware memiliki koefisien serapan linear 0,378 cm-1 dan susut kering 2,6 %. Setelah melalui proses pengayakan tanah liat stoneware memiliki koefisien serapan linear yang praktis sama dengan tanah tanpa pengayakan dan memiliki susut kering 3,6% - 7,0 %.

The clay materials quality analysis uses digital X-ray radiography technique had been conducted. Tests carried out on three types of clay, namely gray earthenware, red earthenware and stoneware which are the results of screening process, with 40, 60, 80, 100, and 120 mesh screen number. Parameters for clay material quality analysis on a digital X-ray radiography measured by calculate the linear absorption coefficient (μ) and shrinkage percentage of dry clay. Gray earthenware clay before screening has a linear absorption coefficient 0,462 cm-1 and shrinkage of 3.6 %. After screening, gray earthenware has a linear absorption coefficient is practically equal to the ground before screening and shrinkage of 4.5 % - 7.9 %. Red earthenware clay before screening has a linear absorption coefficient 0.482 cm-1 and shrinkage of 6.1 %. After screening, linear absorption coefficient of red earthenware is practically equal to the ground before screening and shrinkage of 7.0 % - 10.4 %. Stoneware clay has a linear absorption coefficient of 0.378 cm-1 and shrinkage of 2.6 %. After screening, linear absorption coefficient of stoneware is practically equal to the ground before screening and shrinkage of 3.6 % - 7.0 %.

Kata Kunci : Radiografi digital, tanah liat, pengayakan, mesh, serapan radiasi


    Tidak tersedia file untuk ditampilkan ke publik.