ANALISIS PARAMETER FISIS SERAPAN DAN DIMENSI CITRA PHANTOM HASIL TOMOGRAFI KOMPUTER MENGGUNAKAN SOFTWARE BRILLIANCE CT DAN IMAGEJ

EMERITA SETYOWATI, Dr. Gede Bayu Suparta

2013 | Tesis | S2 Ilmu Fisika

Telah dilakukan analisis parameter fisis serapan dan dimensi citra yang dihasilkan dari proses scan phantom menggunakan tomografi komputer (TK) 64- multi-slice yang terdapat di RSUP Dr. Sardjito Yogyakarta. Protokol yang digunakan dalam proses scan adalah protokol yang sama yang digunakan untuk men-scan pasien yaitu brain, abdomen dan chest. Selanjutnya citra hasil rekonstruksi dianalisis kualitasnya meliputi analisis serapan bahan, dimensi diameter citra, dan dimensi tujuh baris lubang pin bahan acrylic pada multi-pin layer menggunakan software Brilliance CT format citra Digital Imaging Communications in Medicine (DICOM) dan software ImageJ format citra DICOM dan Joint Photographic Experts Group (JPEG). Pengukuran nilai serapan bahan menggunakan software Brilliance CT dalam satuan Hounsfield Units (HU) menunjukkan hasil yang linear dengan nilai referensi, demikian juga pada pengukuran menggunakan software ImageJ pada format citra DICOM. Pada pengukuran menggunakan ImageJ format JPEG hasilnya tidak linear karena citra mengalami kompresi dari 16 bit menjadi 8 bit. Pengukuran dimensi citra menggunakan software Brilliance CT format DICOM dan ImageJ baik format DICOM maupun JPEG menunjukkan bahwa citra hasil rekonstruksi linear terhadap dimensi sebenarnya. Pada pengukuran tujuh baris lubang pin pada bahan acrylic multi-pin layer menggunakan software Brilliance CT hasilnya linear terhadap dimensi sebenarnya. Dimensi terkecil yang bisa diukur adalah 2 mm. Pada pengukuran menggunakan software ImageJ format DICOM dan JPEG hasilnya linear terhadap dimensi sebenarnya. Dimensi terkecil yang bisa diukur menggunakan software ImageJ 1 mm.

Physical parameters analysis of absorption and dimension on Computed Tomography (CT) phantom image produced by 64-multi-slice CT at the Dr. Sardjito General Hospital Yogyakarta has been accomplished. Scanning process based on the same protocol for scanning the patients’ brain, abdomen and chest. Furthermore, the reconstructed image was analyzed based on material absorption, diameter dimensions, and seven rows acrylic pin hole dimension readings of multi-pin layer using computed tomography software in Digital Imaging Communications in Medicine (DICOM) image format and ImageJ software in DICOM and Joint Photographic Experts Group (JPEG) image format. The readings on material absorption measurements using Brilliance CT software in Hounsfield Units (HU) was linear in accordance to the reference value, as well as the measurement using ImageJ software on DICOM image format. On measurement results using ImageJ, the JPEG format was not linear due to the effect of compression of 16 bits to 8 bits images. Diameter dimensions measurements using Brilliance CT software in DICOM format and ImageJ both DICOM and JPEG format image reconstruction results were linear with respect to the actual dimensions. In the seven row acrylic pin holes in multi-pin layer measurement using Brilliance CT software was linear with respect to the actual dimensions. The smallest dimension that can be measured was 2 mm. Measurements using ImageJ software for DICOM and JPEG format was linear with respect to the actual dimensions. The smallest dimension that can be measured using ImageJ software was 1 mm.

Kata Kunci : Tomografi komputer, analisis parameter fisis citra, phantom, dimensi citra


    Tidak tersedia file untuk ditampilkan ke publik.