PENGARUH TURBINE DRIVE -BOILER FEED PUMP TERHADAP HEAT RATE DAN AUXILIARY POWER Pada PLTU Pembangkitan Tanjung Jati B Unit 3&4
SATRIYO NUGROHO, Ir. Bambang Suharnadi, MT
2013 | Tugas Akhir | D3 TEKNIK MESINTingkat efisiensi sebuah power plant tidak hanya berdasarkan seberapa besar energi yang dihasilkan, seberapa besar presentase pemakaian sendiri, tetapi pemakaian bahan bakar (batubara) juga berpengaruh. Besarnya kalor yang dibutuhkan dari batubara untuk menghasilkan energi listrik (heat rate) berdampak terhadap efisiensi power plant. Semakin tinggi nilai nett heat rate, maka tingkat efisiensi power plant juga semakin tinggi. Di power plant, energi yang dihasilkan tidak 100% disuplai ke jaringan melainkan juga digunakan untuk mensuplai kebutuhan energi listrik peralatan penunjang produksi listrik itu sendiri atau disebut sebagai Auxilary Power Consumtion. Di PLTU Tanjung Jati besar penggunaan pemakaian sendiri mencapai 35 MW dari total 710 MW yang dihasilkan. Oleh sebab itu mutlak digunakan pemakaian sendiri agar sistem mampu berjalan dengan baik. Adapun salah satu pemakaian dengan konsumsi listrik tertinggi yaitu pemakaian Boiler Feed Pump. Alat ini berfungsi untuk menaikkan tekanan pada boiler apabila boiler kekurangan pressure dengan cara menambahkan suplai air ke boiler yang kemudian diuapkan yaitu menaikan tekanan air dari 7 bar menjadi 166 bar. Laju pemakaian sendiri ini berpengaruh terhadap efisiensi dari power plant dan besarnya konsumsi bahan bakar. Tugas Akhir ini akan membahas tentang Auxilary Equipment di PLTU Tanjung Jati B Unit 1-2 dan 3-4, yaitu Boiler Feed Pump. Dimana Unit 1-2 menggunakan Motor driven- Boiler Feed Pump sedangkan Unit 3-4 menggunakan Turbine driven- Boiler Feed Pump. Hal inilah yang mempengaruhi tingkat efisiensi di Power Plant.
Level of efficiency of a power plant is not only based on how much energy is produced, how much percentage of own use, but the use of fuel (coal) is also influential. The amount of heat required from coal to generate electrical energy (heat rate) impact on the efficiency of the power plant. The higher value of net heat rate, then the rate of power plant efficiency is also higher. At the power plant, the energy produced is not 100% supplied to the network but is also used to supply electrical energy at supporting equipment of the electrical production itself or referred to as auxilary power consumtion. At the power plant of Tanjung Jati B , the use of his own to reach 35 MW of the total 710 MW generated. Therefore, absolute is used of his own use for the system is able to run properly. one of the highest the use of electricity consumption is the use of the boiler feed pump. This tool serves to increase pressure on the boiler if the boiler get pressure deficiency by adding the water supply to the boiler which was then evaporated is raise the water pressure of 7 bar to 166 bar. Application rate itself affects the efficiency of the power plant and the amount of fuel consumption. The final project will discuss about auxiliary equipment in power plant of Tanjung Jati B units 1-2 and 3-4, it is boiler feed pump. Where Units 1-2 using a motor-driven boiler feed pump while the Units 3-4 use turbine driven-boiler feed pump. This is affecting the level of efficiency in the power plant.
Kata Kunci : Power Plant, Heat Rate, Efisiensi Power Plant, Auxilary Power Consumtion, Boiler Feed Pump