"Efektivitas sistem tandem up flow filter dan resapan rumpon untuk pengolahan limbah cair rumah tangga"

PRAHARA, Sumarno Pudya, Ir. Siti Syamsiyah, Ph.D

2010 | Tesis | S2 Teknik Mesin

Pengolahan limbah cair rumah tangga yang dilakukan masyarakat kita masih pada pengolahan limbah tinja. Limbah dapur cuci, air mandi dan laundry belum menjadi perhatian yang serius. Bukti dilapangan menunjukkan bahwa pengolahan masih bersifat seadanya Permukaan tanah, tanah sungai dan bangunan badan air masih menjadi tumpuan pembuangan limbah tersebut. Tujuan penelitian adalah untuk menguji efektifitas alat alternatif pengolah limbah cair rumah tangga dalam pemisahan lemak minyak dan beberapa zat lain. Penelitian ini diawali dengan studi kasus di lapangan dan studi literer. Alat penelitian yang digunakan adalah instalasi pengolah alternatif limbah air cuci dapur, laundry dan air mandi. Alat terdiri dari bak pemisah lemak minyak, bak penampung lemak minyak, up flow filter dan resapan rumpon. Limbah yang dilakukan pengujian adalah limbah cair dapur, laundry dan air mandi. Pengambilan data debit limbah (Q) dilakukan setiap hari selama (90 hari). Penelitian ini bertujuan menguji efektifitas (1) alat pengolah limbah terhadap pemisahan lemak minyak. (2) Kemampuan alat dalam menurunkan kadar unsur pencemar lainnya. (3) usia pakai dari filter. Hasil pengukuran data menunjukkan bahwa volume limbah air mandi rerata 75,756, air laundry = 64,333, dapur cuci =33,944 liter per hari dan total volume debit limbah rerata = 174,367 liter per hari. Lemak minyak yang terkandung dalam sumber limbah A,B,C teruji = 0,7833%, terhitung =1,366 liter per hari. Lemak minyak terpisah oleh bak pemisah rerata terukur = 0,692 liter per hari. Debit limbah out bak pemisah rerata terhitung = 173,674 liter per hari, dengan kandungan lemak minyak terhitung = 0,452 liter. Lemak minyak Outlet filter 0,118% pada hari pertama = 0,165%, pada hari ke 30, selanjutnya 0,190% = 0pada hari ke 60, dan 0.195% pada hari ke 90. Dari data outlet filter menunjukkan angka peningkatan kandungan lemak minyak yakni 0,076% pada hari ke 90. Berdasar dari analisa data dan grafik komulatif output limbah dapat diketahui bahwa waktu jenuh filter yakni setelah 85 bulan pemakaian. Bila mengacu pada baku mutu, diperoleh waktu penggantian filter setelah 126 bulan pemakaian. Unsur lain terhitung untuk clorida = 248,848 mg per liter, turun menjadi 88,975 mg per liter = (96,56%). Phosphat dari 66,500 turun menjadi 5,500 mg per liter = (81,86%). Nitrat dari 2,470 menjadi 0,1246 mg per liter = (78%). pH out rerata dari 5,11 naik menjadi 7,40. COD (KmnO4) dari 692,450 turun menjadi 44,353 mg per liter =(92,58%). BOD5.20 dari 523,003 menjadi 16,008 mg per liter = (94,22%)

Domestic wastewater treatment by our society is still too focused on sludge treatment. Waste kitchen sinks, bath and laundry water has not become a serious concern. Field evidence indicates that processing is still sober even still often found with no management at all. Soil surface, soil and artificial water bodies and nature is still a focus for the disposal of the waste. This research aims to uncover the oil and fat content Clorida element, Phosphate, Nitrate, pH, COD (KMnO 4), and BOD 5:20 and calculation ability to separate elements of the effectiveness of the installation in the oil-fat and some other elements and the laundering or replacement of filters on washing waste kitchen, laundry and bath water. The methods applied to liquid waste by testing the concentration of fatty oil conducted at the Laboratory CHE-MIX PRATAMA and to other elements Clorida, Phosphate, Nitrate, pH, COD (KMnO 4), and BOD 5:20 Laboratory tests conducted on Sanitation and Environmental Engineering Civil Engineering University of Gajah Mada. The tools and research are built and carried directly to households in the hamlet intalation Talangrejo RT 04, RW 34, kalurahan Wedomartani, Ngemplak, Sleman, Yogyakarta, in the form of fat-oil separator unit installation and construction of tandem Up flow filter with absorption types rumpon (fads). Data includes average wastewater discharge (input separator) of 174.3667 liters per day, with average oil content of fats tested = 0.7833%, oil fats separately measured mean = 0.692 liters per day. Input filter average count = 173.674 liters per day with fat content starting oil = 0.452 liters. Fat Outlet oil filter tested first 30 days of 0.118%, 0.165% at 30 days into the second, then 0.190% in the third 30 days 30 days 0195% in the fourth. From the data outlets, the decline in the ability of the filter was shown to decrease the fat content is indicated by an increase in oil output up to 120 days of usage amounted to 0.077%. From the data analysis and refers to the cumulative graph the fat content of oil in the filter outlet reached 19.9267 mg per liter at 90 months of use, if drawn dispose of waste quality standard of 20 mg per liter. Another element that can filter the filters counted for clorida of 248.848 mg per liter, fell to 88.975 mg per liter (96.56%). Phosphate from 66.500 mg per liter, down to 5.500 mg per liter (81.86%). Nitrate of 2.470 mg per liter to 0.1246 mg per liter (78%). PH out the average rose to 7.40 from 5.11. COD (KMnO 4) of 692.450 mg per liter, fell to 44.353 mg per liter (92.58%). 5:20 BOD from 523.003 mg per liter, to 16.008 mg per liter (94.22%).

Kata Kunci : Limbah cair rumah tangga non tinja,Bak pemisah,Lemak minyak,Up flow filter,Resapan rumpon


    Tidak tersedia file untuk ditampilkan ke publik.