Laporkan Masalah

Karakteristik dinamik Hotel Ambarukmo menggunakan data seismometer

APRIANSYAH, Rikhi, Ir. Hrc. Priyosulistyo, M.Sc., Ph.D

2010 | Tesis | S2 Teknik Sipil

Karakteristik dinamik path suatu struktur bangunan dapat diketahui melalui frekuensi alami bangunan dan Amplitudo. Apabila percepatan yang didapat dari respon spektrum hasil getaran microtremor dapat diketahui maka amplifikasi struktur dapat dihitung bila percepatan tiap lantai dan basement telah ditetapkan, Kemudian indeks kerentanan hangunan dapat dihitung bila faktor ampilfikasi strukttzr, frekuensi alarni gedung dan ketinggian amat tingkat ditetapkan. Percepatan rnakcimum gedung juga dapat dihitung bila faktor amplifikasi antar lantai, frekuensi antar lantai, frekwensi alami, ketinggian antar lantai dan story drift telah ditetapkan. Seismorneter merupakan alat yang dapat merekam gecaran yang sangat kecìî sehingga dapat mengetahui karakteristilc dinamik gedung. Pada penelitian ini diuji sedang Ambarukmo Hotel yang teiah berusia 46 Tahun dan mengalami beberapa kali gempabumi sedang sampai besar maka dimungkinkan kekuatan telah berkurang dari perencanaan. Tiga komponen pada seismoineter U-D (Up-Down), U-S (utara-selatan). dan T-B (timur-barat) merekam getaran microtremor secara bersamaan. Pengujiaan dilakukaji pada basement, Lantai 3, lantai 6 dan lamai 8. Pengujian dilakukan di dua titik yang berbeda pada sisi barat dan sisi timur pada waklu lidak bersarnaan. Hasil perekarnan berupa time history lalu diolah menjadJ respon spektrum untuk mengetahui frekuensi alarni bangunan dan ampiltudo percepatan. Frekuerisi alami yang didapat dan eksperimeri ini dibandingkan dengan frekuensi alami numerik. Hasil pengujiaan eksperimen didapatkan fiekuensi alarni Gedung Ambarukmo Hotel pada arah utara-selatan 3,759 Hz dan arah timur-barat 2,002 Hz. Indeks kerentanan stnuktur terbesar berada pada lantai 6 sampai dengan lantai 8, hal ini mengindikasikan akan tejadi kerusakan awal pada lantai 6 sampai 8 jika terjadi gempa bumi besar sekali. Peroepalan maksimum yang tidak dapat diterima oleb gedung bila lebih besar dan 932,23 gaI. Nilai ini masih memenuhi persyaratan yang telah ditetapkan oleh SNI-03-l 726-2002 untuk wilayah gempa 4 (2(X) gal). Hasil pengujian numerik dengan menunakan SAP 2000 mendapatkan nilai frekuensi alami pada arah utara-selatan 3,747 Hz dan arah timur-barat 2,161 Hz.

Dynamic characteristics of a building structure can be known through the ncauralfrequency and amplitude of the building. If the acceleration response spectra obtained from microtremor vibrations result can be known to the amplijìcation of the structure can be calculated ¡f the acceleration of each floor and the basement has been set Then the building vulnerability index can be calculated if the ampilfikasi factor structure, ¡he natural frequency and height of buildings between the level set. The maximum acceleration of the building can also be calculated when the ampljfìcation factor between floors, the natural frequency, the height between thefloor and story &j/Ì has been determined Seismometer is a tool that can record a very small vibration that can find the dynamic characteristics of the building. In this study tested Ámbarukmo Hotel which has 46 year old and has expErienced several nvderase to large earthquakes ills possible the power has been reduced from planning Three components of the Seismometer UD (tip-Down), US (north-south), and T-B (east-west) rnicrotremor vibrations recorded simultaneously Pengujiaan done in the basement, 3rd floor, 6th floor and 8th floor. Testing is done at two dj(ferent points on the west side and east side at the same time nui Results oftime history recording and then processed into a response spectrum to determine the natural frequency and amplitude of the acceleration of the building. Naturalfrequencies obtained from this experiment compared with the natural frequencies numerically. The results q! experiments obtained pengujiaan natural frequency Ambarukmo Hotel on the north-south direction of .3, 759 Hz and east-west direction of 2,002 Hz. Vulnerability index was the largest structure on the 6th floor to the 8th floor, this would indicate early damage to the floor 6 to 8 in case of very large earthquakes. Maximum acceleration that can not be accepted by the building when more than 932,23 gaL This value still meets the requirements set by the SNI-03-1726-2002 to the earthquake region 4 (200 gal) tiumerical test results by using the S4P 2001)10 get the value of natural frequency on the north-south direction of 3,747 Hz and the east-west direction of2,161 Hz

Kata Kunci : Seismometer,Karakteristik dinamik,Indeks kerentanan,Percepatan maksimum


    Tidak tersedia file untuk ditampilkan ke publik.