Rancangan dan implementasi prototipe sistem pengukuran ketinggian air sungai sebagai bagian dari peringatan dini banjir di Jakarta berbasis mikrokontroler AT89S52
ABDILLAH, Gunawan, Drs. Jazi Eko Istiyanto, M.Sc., Ph.D
2009 | Tesis | S2 Ilmu KomputerSetiap kali terjadi banjir di Jakarta sering terdengar ungkapan banjir itu kiriman dari Bogor. Tudingan itu muncul karena hampir semua sungai yang bermuara di Jakarta berhulu di wilayah Bogor. Untuk mendeteksi banjir kiriman diperlukan suatu sistem yang dapat mengukur ketinggian air di daerah aliran sungai yang berhilir di Jakarta. Penulisan tugas akhir ini mengaplikasikan sistem pengukuran ketinggian air yang memanfaatkan teknologi SMS sebagai media pengiriman informasi yang berisi data ketinggian air, debit, dan status ketinggian. Sistem yang telah dibuat terdiri dari sensor, mikrokontroler, memori eksternal, real-time clock, dan perangkat komunikasi. Data ketinggian air beserta waktu nyata disimpan dalam memori eksternal untuk keperluan pelaporan. Dari hasil pengujian terhadap sistem diperoleh besarnya kesalahan pengukuran (Sqi) yang paling baik yaitu pada pengujian akurasi yang ke-2 sebesar ± 2,8 cm, pengujian ketepatan yang paling baik yaitu pada pengujian ketinggian air 200 cm, pada posisi 80% dari skala maksimum dimana kesalahan ketepatan pengukuran diperoleh sebesar 0%.
Each time flood strikes Jakarta, it has become a common notion that the mass of water must have disgorged from a neighboring city, Bogor. This common notion is reasonable as most rivers that flow through Jakarta have their origin in the high lands of Bogor. This study attempts to devise a flood potential earlywarning system by means of real-time accumulation of water elevation data of rivers in Bogor that flow through Jakarta. The water elevation measurement system consists of sensors, microcontroller, external memory, real-time clock, and communication devices. Records of water elevation data are stored in the memory for external reporting system. The reporting system utilizes short messaging system (SMS) telecommunications as a means to send information packets containing water elevation level, debit, and elevation status. The system testing conducted in this study indicates a measurement error (Sqi) with accuracy of ± 2.8 cm. The accuracy of the test was highest on water altitude of 200 cm and at position 80% of the maximum scale, at which the measurement error is equal to 0%.
Kata Kunci : SMS,Mikrokontroler,Sensor,Ketinggian air,Banjir, SMS, Micro-controller, Sensor, Altitude of water, Flood