Laporkan Masalah

Evaluasi Perubahan Laju Dosis Radiasi Eksternal Pasien Terapi Iodium-131 Selama Penerapan Modifikasi Suhu Ruangan Dan Protokol Mandi Terstandar

Kenya Puspita Yanuardani, Ir. Fitrotun Aliyah, ST., MT., Ph.D. ; dr. Hanif Afkari, Sp.KN-TM, Sub.Sp.Onk(K).

2026 | Skripsi | TEKNIK NUKLIR

Terapi radioiodin (131I) mengharuskan pasien berisolasi sampai paparan radiasi eksternal turun di bawah batas aman pelepasan (<=70 uSv/jam). Radioiodin yang dikeluarkan melalui perspirasi dapat menempel pada kulit dan menghambat penurunan dosis paparan eksternal (External Dose Rate/EDR), sehingga masa rawat menjadi lebih lama. Penelitian ini bertujuan mengevaluasi apakah suhu ruang isolasi dan protokol mandi standar dapat memperpendek waktu paruh efektif (Teff) dan mempercepat penurunan EDR setelah terapi 131I.  

Penelitian ini melibatkan 27 pasien pasca-tiroidektomi dengan aktivitas 131I sebesar 30 mCi untuk ablasi. Pendingin ruangan diatur pada 27°C, asupan cairan dan frekuensi BAK dicatat, dan protokol mandi standar dilakukan pada jam ke-6 setelah intake. Pengukuran EDR diambil pada jarak 1 m pada jam ke-0,5, 3, 6 (sebelum dan sesudah mandi), 8, dan 20. Analisis data menggunakan uji Wilcoxon Signed Rank dan korelasi Spearman Rank.

Hasil menunjukkan bahwa protokol mandi standar menurunkan EDR pada 81,5% pasien, dengan penurunan 1% hingga 47% (p <0>Teff (p > 0,05). Pada jam ke-20, rerata EDR kelompok intervensi sebesar 15,42  uSv/jam, sedangkan satu pasien referensi memiliki EDR sebesar 26,27 uSv/jam, sehingga perbandingan hanya dapat dilakukan secara deskriptif.

Radioiodine therapy (131I) requires patient isolation until external radiation exposure falls below the safe release limit of 70 uSv/hour. Radioiodine excreted through perspiration may remain on the skin and contribute to external dose rate (EDR). This study evaluated whether isolation room temperature and a standardized bathing protocol could shorten the effective half-life (Teff) and accelerate EDR reduction after 131I therapy.

This study involved 27 post-thyroidectomy patients receiving 30 mCi of 131I. The room temperature was set to 27°C, fluid intake was recorded, and standardized bathing was performed 6 hours after intake. EDR was measured at 1 m at 0.5, 3, 6 (before and after bathing), 8, and 20 hours. Data were analyzed using the Wilcoxon Signed-Rank test and Spearman Rank correlation.

Standardized bathing reduced EDR in 81.5% of patients, with decreases of 1–47%. Fluid intake and voiding frequency were not correlated with Teff. All intervention patients met the release criterion by 20 hours, with a final EDR of 15.42 uSv/hour, compared with 26.27 uSv/hour in the reference patient.

Kata Kunci : Iodium-131, laju dosis eksternal, dekontaminasi mandi, termoregulasi

  1. S1-2026-503418-abstract.pdf  
  2. S1-2026-503418-bibliography.pdf  
  3. S1-2026-503418-tableofcontent.pdf  
  4. S1-2026-503418-title.pdf