Laporkan Masalah

Pengaruh Penghawaan Kombinasi terhadap Kenyamanan Termal di Green Classroom

Akmaliadi, Dr. Eng. Nedyomukti Imam Syafii, S.T., M.Sc

2026 | Tesis | S2 Teknik Arsitektur

Penghawaan kombinasi berupa pendingin udara (AC) dan kipas plafon merupakan salah satu strategi untuk meningkatkan efisiensi energi sekaligus mempertahankan kenyamanan termal pada bangunan. Strategi ini telah diterapkan pada ruang kelas di Smart and Green Learning Center (SGLC) Universitas Gadjah Mada yang berkonsep bangunan Green Building, akan tetapi efektivitasnya belum pernah dikaji dari segi persepsi pengguna. Oleh karena itu penelitian ini bertujuan mengkaji pengaruh penghawaan kombinasi AC dan kipas plafon terhadap persepsi kenyamanan termal mahasiswa di green classroom. Penelitian ini menggunakan pendekatan studi lapangan (field study) pada sembilan penghawaan kombinasi yang terdiri dari tiga setpoint AC (25°C, 26°C, dan 27°C) serta tiga tingkat kecepatan kipas. Data yang dikumpulkan meliputi parameter lingkungan termal menggunakan alat ukur termal dan persepsi kenyamanan termal menggunakan kuesioner. Sebanyak 478 mahasiswa berpartisipasi dalam penelitian ini dan menghasilkan 1.401 respons kuesioner yang valid dari total 1.471 respons yang terkumpul selama 27 sesi pengukuran. Data selanjutnya dianalisis menggunakan statistik deskriptif dan inferensial melalui model regresi linear. Hasil penelitian menunjukkan bahwa penghawaan kombinasi AC dan kipas plafon efektif dalam mempertahankan kenyamanan termal pada ruang kelas. Persepsi termal mahasiswa dipengaruhi secara signifikan oleh interaksi antara suhu udara dan kecepatan udara, dengan suhu udara sebagai faktor yang paling dominan, sedangkan peningkatan kecepatan udara berfungsi sebagai mekanisme kompensasi yang memungkinkan kenyamanan tetap terjaga pada suhu ruang yang lebih tinggi. Suhu netral mahasiswa diperoleh sebesar 27,08°C, lebih tinggi dibandingkan suhu preferensi sebesar 24,59°C, yang menunjukkan bahwa mahasiswa mampu mentoleransi suhu yang lebih hangat, meskipun lebih menyukai kondisi termal yang sedikit lebih dingin. Selain itu, keterbatasan model prediksi PMV dalam merepresentasikan persepsi termal aktual mahasiswa menunjukkan bahwa evaluasi kenyamanan termal pada ruang kelas ber-AC yang dikombinasikan dengan kipas plafon perlu mempertimbangkan respons subjektif pengguna. Secara keseluruhan, hasil penelitian ini menunjukkan bahwa kombinasi AC dan kipas plafon berpotensi menjadi strategi penghawaan yang mampu mendukung kenyamanan termal sekaligus meningkatkan efisiensi energi pada green classroom.



Mixed-mode cooling, combining air conditioning (AC) and ceiling fans, is one strategy for improving energy efficiency while maintaining thermal comfort in buildings. This strategy has been implemented in the classrooms of the Smart and Green Learning Center (SGLC) at Universitas Gadjah Mada, which is designed based on the Green Building concept. However, its effectiveness from the users’ perspective has not yet been evaluated. Therefore, this study aims to examine the effect of mixed-mode cooling using AC and ceiling fans on students’ thermal comfort perception in a green classroom. This study employed a field study approach involving nine mixed-mode cooling configurations, consisting of three AC setpoints (25°C, 26°C, and 27°C) and three ceiling fan speed levels. Data were collected through measurements of thermal environmental parameters using thermal measurement instruments and assessments of thermal comfort perception through questionnaires. A total of 478 students participated in the study, generating 1,401 valid questionnaire responses from 1,471 responses collected across 27 measurement sessions. The data were subsequently analyzed using descriptive and inferential statistics through linear regression models. The results show that mixed-mode cooling using AC and ceiling fans is effective in maintaining thermal comfort in classrooms. Students’ thermal perceptions were significantly influenced by the interaction between air temperature and air speed, with air temperature being the most dominant factor. Meanwhile, increased air speed functioned as a compensatory mechanism that allowed thermal comfort to be maintained at higher indoor temperatures. The students’ neutral temperature was found to be 27.08°C, which was higher than their preferred temperature of 24.59°C. This finding indicates that students were able to tolerate warmer thermal conditions, although they preferred slightly cooler environments. Furthermore, the limitations of the PMV prediction model in representing students’ actual thermal perceptions indicate that thermal comfort assessments in air-conditioned classrooms using mixed-mode cooling should consider users’ subjective responses. Overall, the findings demonstrate that mixed-mode cooling using AC and ceiling fans has the potential to support thermal comfort while improving energy efficiency in green classrooms.


Kata Kunci : Kata kunci: Penghawaan Kombinasi (AC-Kipas plafon), Persepsi Kenyamanan Termal, Green Classroom

  1. S2-2026-547146-abstract.pdf  
  2. S2-2026-547146-bibliography.pdf  
  3. S2-2026-547146-tableofcontent.pdf  
  4. S2-2026-547146-title.pdf