Optimasi Window-To-Wall Ratio (WWR) dan Pemilihan Material Jendela dalam Mencapai Efisiensi Energi dan Kelayakan Investasi pada Unit Kamar di Hotel Voyou Surakarta
Hidayah Salsabiela Nugraharti, Dr. Yani Rahmawati, S.T., M.T.
2026 | Tesis | S2 Teknik Arsitektur
Sektor bangunan, khususnya hotel, merupakan konsumen energi yang signifikan karena beroperasi penuh selama 24 jam dengan beban pendinginan sebagai komponen terbesar. Di iklim tropis seperti Surakarta, desain selubung bangunan menghadapi dilema antara kebutuhan estetika visual melalui bukaan jendela yang lebar dan upaya meminimalkan perolehan panas matahari. Meskipun teknologi kaca berkinerja tinggi tersedia sebagai solusi, penerapannya sering terhambat oleh biaya investasi awal yang tinggi dan ketidakpastian pengembalian modal. Penelitian ini bertujuan untuk menentukan kombinasi optimal antara Window-to-Wall Ratio (WWR) dan jenis material kaca yang dapat meminimalkan konsumsi energi sekaligus memenuhi kelayakan finansial pada Unit Kamar Hotel Voyou Surakarta. Penelitian ini menggunakan metode campuran (mixed-method) dengan pendekatan kuantitatif berbasis simulasi sebagai inti utama, didukung pendekatan kualitatif melalui wawancara mendalam dengan tiga narasumber ahli. Simulasi energi dilakukan menggunakan Autodesk Revit 2025 dan OpenStudio terhadap 20 skenario kombinasi variasi WWR dan empat jenis material kaca dari katalog PT Asahimas Flat Glass Tbk, yang menghasilkan nilai Energy Use Intensity (EUI) sebagai indikator kinerja utama. Hasil simulasi selanjutnya dianalisis menggunakan metode Payback Period untuk mengevaluasi kelayakan finansial setiap skenario. Hasil penelitian menunjukkan bahwa peningkatan WWR secara konsisten meningkatkan nilai EUI pada seluruh material kaca yang diuji, dengan kenaikan yang semakin tajam di atas rentang WWR 40%. Dari sisi material, Sunergy Blue Green sebagai kaca Low-E menghasilkan nilai EUI terendah secara konsisten pada setiap skenario berkat nilai SHGC 0,35 yang paling rendah di antara seluruh material yang diuji. Kombinasi WWR 40% pada orientasi barat laut dan tenggara dengan material kaca Sunergy Blue Green ditetapkan sebagai rekomendasi optimal karena memenuhi empat kriteria secara bersamaan, yaitu nilai EUI 275,84 kWh/m²/tahun yang berada di bawah standar ASEAN USAID sebesar 300 kWh/m²/tahun, payback period 2,08 tahun dengan annual saving sebesar Rp 83.694.468 per tahun, dimensi bukaan yang memadai untuk kenyamanan penghuni, serta ketersediaan material di pasar lokal Surakarta. Temuan ini membuktikan bahwa optimasi selubung bangunan hotel di iklim tropis harus mempertimbangkan keseimbangan antara proporsi bukaan, kinerja termal material kaca, dan kelayakan investasi secara bersamaan sebagai satu kesatuan strategi desain yang terintegrasi.
The building sector, particularly hotels, represents a significant energy consumer due to its full 24-hour operation with cooling systems as the largest energy component. In tropical climates such as Surakarta, building envelope design faces a dilemma between the aesthetic need for wide window openings and the effort to minimize solar heat gain. Although high-performance glazing technology is available as a solution, its implementation is often hindered by high initial investment costs and uncertainty regarding return on investment. This study aims to determine the optimal combination of Window-to-Wall Ratio (WWR) and glazing material type that can minimize energy consumption while meeting financial feasibility requirements at Hotel Voyou Surakarta. This study employs a mixed-method approach with simulation-based quantitative analysis as the primary method, supported by a qualitative approach through in-depth interviews with three expert informants. Energy simulations were conducted using Autodesk Revit 2025 and OpenStudio across 20 scenario combinations of WWR variations and four glazing material types from the PT Asahimas Flat Glass Tbk product catalog, generating Energy Use Intensity (EUI) values as the primary performance indicator. Simulation results were subsequently analyzed using the Payback Period method to evaluate the financial feasibility of each scenario. The results indicate that increasing WWR consistently raises EUI values across all tested glazing materials, with a steeper increase beyond the 40% WWR threshold. In terms of material performance, Sunergy Blue Green as the sole Low-E glass consistently produced the lowest EUI values across all scenarios, attributed to its SHGC value of 0.35, which was the lowest among all tested materials. The combination of 40% WWR on both the northwest and southeast orientations with Sunergy Blue Green glazing material was established as the optimal recommendation, as it simultaneously satisfies four criteria: an EUI value of 275.84 kWh/m²/year which falls below the ASEAN USAID standard of 300 kWh/m²/year, a payback period of 2.08 years with an annual saving of IDR 83,694,468, adequate window dimensions for occupant visual comfort, and material availability in the local Surakarta market. These findings demonstrate that optimizing the building envelope of hotels in tropical climates must simultaneously consider the balance between window proportions, glazing thermal performance, and investment feasibility as an integrated design strategy.
Kata Kunci : Efisiensi Energi, Window-to-Wall Ratio (WWR), Material Kaca, Unit Kamar Hotel, Energy Use Intensity (EUI), Payback Period, BIM, dan Iklim Tropis.