Laporkan Masalah

Bi-Level Sizing of a Grid-Connected PV–HESS–EV Campus Microgrid Considering Cost and Battery Degradation under Time-of-Use and Demand-Charge Tariffs

Rahma Salsabiella Adhinintia, Ir. Agus Darmawan, S.T., M.S., Ph.D., IPM., ASEAN Eng

2026 | Tesis | S2 Teknik Industri

Meningkatnya pemanfaatan energi terbarukan mendorong pengembangan pembangkit fotovoltaik (PV) dan sistem penyimpanan energi. Pada microgrid kampus, Hybrid Energy Storage System (HESS) mengombinasikan baterai untuk pengelolaan energi jangka panjang dan superkapasitor (SC) untuk merespons fluktuasi daya jangka pendek. Fleksibilitas sistem juga dapat ditingkatkan melalui vehicle-to-grid (V2G) dengan memanfaatkan kendaraan listrik yang terhubung ke jaringan. Namun, optimasi PV, HESS, dan V2G secara terpadu pada resolusi dispatch 5 menit dengan mempertimbangkan biaya sistem dan degradasi baterai masih terbatas.
Penelitian ini mengembangkan kerangka kerja bi-level multiobjektif untuk microgrid kampus berbasis PV yang terhubung ke jaringan dengan mengacu pada tarif Taipower. Lapisan luar menggunakan Non-dominated Sorting Genetic Algorithm II (NSGA-II) untuk menentukan ukuran komponen, sedangkan lapisan dalam menggunakan Mixed-Integer Linear Programming (MILP) untuk optimasi dispatch 5 menit. Model degradasi berbasis metode rainflow digunakan untuk mengevaluasi dampak siklus baterai pada tiga arsitektur penyimpanan. Dibandingkan konfigurasi baterai saja, konfigurasi HESS+V2G mengurangi kapasitas energi baterai stasioner sekitar 25% menjadi 3,46 MWh dan menurunkan daya nominal lebih dari 50%. Degradasi akibat siklus baterai berkurang sekitar 13% sehingga estimasi masa pakai meningkat menjadi 11,1 tahun. Konfigurasi ini menghasilkan Levelized Cost of Energy (LCOE) terendah sebesar 4,88 TWD/kWh (? Rp2.708/kWh) dan mengurangi emisi karbon sekitar 2.456 tCO?e per tahun dibandingkan baseline jaringan listrik. Sekitar 21 kendaraan telah mampu memberikan sebagian besar manfaat V2G. Hasil penelitian menunjukkan bahwa koordinasi HESS dan V2G dapat meningkatkan efisiensi biaya dan umur baterai pada microgrid kampus berbasis PV.

The increasing focus on renewable energy has led to greater demand for photovoltaic (PV) generation and energy storage. In urban campus microgrids, hybrid energy storage systems (HESS) combine batteries for longer-term energy management with supercapacitors (SC) for short-term power fluctuations. By handling these rapid changes, the SC can reduce the need for frequent battery responses. Further flexibility can be provided by vehicle-to-grid (V2G) using connected electric vehicles. However, the sizing and operation of PV, HESS, and V2G are rarely optimized together at a 5-minute dispatch resolution while considering total system cost and battery cycling.
This study develops a bi-level multi-objective framework for a grid-connected PV campus microgrid under the Taipower tariff. The outer layer uses NSGA-II for component sizing, while the inner layer applies mixed-integer linear programming (MILP) for 5-minute dispatch. A rainflow-based degradation model is included to quantify battery cycling across three storage architectures. Relative to the battery only case, the HESS+V2G configuration cuts stationary battery energy by roughly 25% to 3.46 MWh and lowers rated power by more than half. Cycling degradation falls by about 13%, which extends the estimated battery lifetime to 11.1 years. This configuration also delivers the lowest levelized cost of energy at 4.88 TWD/kWh (? IDR 2,708/kWh) and avoids some 2,456 tCO?e of annual carbon emissions relative to the grid-only baseline. Most V2G benefits emerge with partial fleet participation, as around 21 vehicles capture the majority of the savings. Overall, coordinated HESS and V2G operation can improve the cost and durability of PV based campus microgrids.  

Kata Kunci : Hybrid energy storage system, Microgrid sizing optimization, Bi-level optimization, Vehicle-to-grid (V2G), Battery degradation

  1. S2-2026-541115-abstract.pdf  
  2. S2-2026-541115-bibliography.pdf  
  3. S2-2026-541115-tableofcontent.pdf  
  4. S2-2026-541115-title.pdf