SISTEM PEMANTAUAN DAN PENGENDALIAN REAL-TIME KINERJA MOTOR BLDC BERBASIS FUZZY LOGIC CONTROL DENGAN PSoC UNTUK PERAHU LISTRIK

UUN TRIYAS YUNI KURNIAWAN, Prof. Dr. Ir. Faridah, S.T., M.Sc., IPU., ASEAN Eng. ; Prof. Ir. Sunarno, M.Eng., Ph.D., IPU.

2026 | Tesis | MAGISTER TEKNIK FISIKA

Pengembangan perahu listrik air tawar memerlukan sistem propulsi yang responsif, teredam, dan tetap dapat dievaluasi ketika beban berubah. Penelitian ini merancang serta mengevaluasi sistem pemantauan dan pengendalian kecepatan motor Brushless Direct Current (BLDC) berbasis Fuzzy Logic Control (FLC) pada PSoC 5LP. Keaslian penelitian ditekankan pada integrasi native telemetry ESC, akuisisi torsi mekanis, dan pengendali tertanam dalam satu sistem uji, bukan pada klaim bahwa FLC atau Differential Evolution (DE) merupakan metode baru. Metode penelitian meliputi pemodelan motor BLDC, perancangan PID sebagai baseline, penalaan PID-DE, perancangan FLC-5 dan FLC-7, serta penalaan FLC-DE secara offline menggunakan DE. Tegangan, arus, kecepatan, dan suhu diperoleh dari ESC Votol EM-50 melalui UART. Torsi diperoleh melalui mekanisme swinging arm, load cell, HX711, dan ESP32. PID-DE dan FLC-DE diuji pada PSoC dengan lima ulangan pada skenario respons transien, efisiensi, dan gangguan beban yang disetarakan. Verifikasi kanal telemetri menghasilkan galat relatif tegangan sebesar 0,21–0,25?n galat relatif arus sebesar 0,93–1,20%, sedangkan perbedaan rata-rata torsi terhadap pembanding sebesar 3,53%. Model analitik tervalidasi dengan RMSE 15,78 rpm. Pada set point 2000 rpm, FLC-DE menghasilkan rise time 0,70 s, settling time 1,00 s, dan overshoot 0,05%, sedangkan PID menghasilkan 0,80 s, 1,32 s, dan 2,96%. PID-DE menghasilkan rise time 0,55 ± 0,00 s, settling time 0,70 ± 0,00 s, dan overshoot 0,85 ± 0,09%. Efisiensi rata-rata pada beban bukan nol sebesar 78,40% untuk PID, 82,60% untuk PID-DE, dan 88,90% untuk FLC-DE. Pada gangguan beban 0,56 N m, penurunan kecepatan maksimum PID-DE sebesar 42,62 ± 1,27 rpm, sedangkan FLC-DE sebesar 14,40 ± 1,14 rpm. PIDDE memberikan respons awal paling cepat, sementara FLC-DE menunjukkan redaman overshoot, efisiensi, dan ketahanan gangguan beban terbaik pada konfigurasi laboratorium yang diuji. Tugas kendali internal dirancang berperiode 1 ms dan pembaruan telemetri berlangsung sekitar 50 ms. Karena worst-case execution time, jitter, dan latensi ujung-keujung belum diukur, klaim real-time dibatasi pada kesiapan arsitektur soft real-time, bukan verifikasi hard real-time. 

Freshwater electric boats require propulsion systems that are responsive, well damped, and measurable under changing loads. This study designed and evaluated a Brushless Direct Current (BLDC) motor speed monitoring and control system based on Fuzzy Logic Control (FLC) using a PSoC 5LP. The originality lies in integrating ESC native telemetry, mechanical torque acquisition, and embedded control within one experimental system, rather than claiming that FLC or Differential Evolution (DE) is a new method. The method included BLDC motor modeling, PID design as a baseline, PID-DE tuning, FLC-5 and FLC-7 design, and offline FLC-DE tuning using DE. Voltage, current, speed, and temperature were acquired from a Votol EM-50 ESC through UART. Torque was measured using a swinging arm, load cell, HX711, and ESP32. PID-DE and FLC-DE were implemented on the PSoC and evaluated through five repetitions under equivalent transient, efficiency, and load-disturbance scenarios. Telemetry verification produced relative voltage errors of 0.21–0.25% and relative current errors of 0.93–1.20%, while the mean torque difference from the reference was 3.53%. The analytical model was validated with an RMSE of 15.78 rpm. At a 2000 rpm set point, FLC-DE achieved a rise time of 0.70 s, a settling time of 1.00 s, and an overshoot of 0.05%, whereas PID produced 0.80 s, 1.32 s, and 2.96%. PID-DE produced 0.55±0.00 s, 0.70±0.00 s, and 0.85±0.09%, respectively. Mean efficiency under nonzero loads was 78.40% for PID, 82.60% for PID-DE, and 88.90% for FLC-DE. Under a 0.56 N m load disturbance, the maximum speed drop was 42.62 ± 1.27 rpm for PID-DE and 14.40 ± 1.14 rpm for FLC-DE. PID-DE provided the fastest initial response, whereas FLC-DE showed the best overshoot damping, efficiency, and load-disturbance robustness within the tested laboratory configuration. The internal control task was configured at 1 ms, while telemetry was updated at approximately 50 ms. Because worst-case execution time, jitter, and end-to-end latency were not measured, the real-time claim is limited to soft real-time architectural readiness rather than verified hard real-time performance. 

Kata Kunci : Motor BLDC, Fuzzy Logic Control, Differential Evolution, PSoC, Perahu Listrik

  1. S2-2026-548024-abstract.pdf  
  2. S2-2026-548024-bibliography.pdf  
  3. S2-2026-548024-tableofcontent.pdf  
  4. S2-2026-548024-title.pdf