INVERTER OVERSIZING STRATEGY TO MITIGATE VOLTAGE RISE IN DISTRIBUTION NETWORKS WITH HIGH PV PENETRATION

Mahib Miftahul Falah, Dr. Wijaya Yudha Atmaja, S.T., M.Eng.; Husni Rois Ali, S.T., M.Eng., Ph.D., DIC., SMIEEE.

2026 | Skripsi | TEKNIK ELEKTRO

Integrasi masif sistem Photovoltaic (PV) pada jaringan distribusi menimbulkan tantangan signifikan terhadap stabilitas tegangan, khususnya terjadinya overvoltage (kenaikan tegangan berlebih) pada Point of Common Coupling (PCC) saat iradiasi matahari mencapai puncaknya. Meskipun Active Power Curtailment (APC) efektif dalam mengurangi kenaikan tegangan tersebut, metode ini menimbulkan kerugian finansial yang signifikan akibat energi bersih yang terbuang, sehingga menurunkan kelayakan ekonomi sistem. Penelitian ini mengusulkan strategi oversizing inverter dengan memanfaatkan kontrol Volt-Var sebagai alternatif, yang menyediakan cadangan kapasitas daya reaktif untuk mengatur tegangan tanpa harus membuang daya aktif. Untuk mengatasi kompleksitas trade-off teknis-ekonomi, diusulkan sebuah kerangka kerja optimasi dua tahap yang diuji pada unbalanced IEEE 8500-node test feeder. Tahap pertama, algoritma Multi Objective Particle Swarm Optimization (MOPSO) digunakan untuk menentukan lokasi dan kapasitas optimal penempatan PV. Selanjutnya, algoritma Particle Swarm Optimization (PSO) digunakan untuk menentukan faktor oversize inverter yang optimal dengan meminimalkan total biaya harian, yang mencakup rugi-rugi jaringan, penalti curtailment, dan amortisasi inverter. Analisis komparatif terhadap lima skenario operasional menunjukkan bahwa skema Volt-Var dengan oversizing optimal merupakan solusi paling layak. Hasil optimasi berhasil mempertahankan total biaya operasional harian jaringan terendah dengan curtailment daya aktif nol. Dengan demikian, strategi ini berhasil mengatasi permasalahan overvoltage sekaligus memaksimalkan keandalan jaringan dan efisiensi energi terbarukan.

The massive integration of Photovoltaic (PV) systems in distribution networks introduces significant voltage stability challenges, particularly the occurrence of overvoltage at the Point of Common Coupling (PCC) during peak solar irradiance. While Active Power Curtailment (APC) effectively mitigates these voltage rises, it inflicts significant financial penalties due to discarded clean energy, thereby reducing the system’s economic viability. This study proposes an inverter oversizing strategy utilizing Volt-Var control as an alternative, providing reactive power reserve capacity to regulate voltage without discarding active power. To navigate the complex techno-economic trade-offs, a twostage optimization framework is proposed and tested on the unbalanced IEEE 8500-nodet test feeder. First, a Multi-Objective Particle Swarm Optimization (MOPSO) algorithmi is deployed to identify the optimal PV placement and capacity. Subsequently, a Particle Swarm Optimization (PSO) algorithm is utilized to determine the optimal inverter oversize factors by minimizing the total daily cost, which includes network losses, curtailment penalties, and inverter amortization. A comparative analysis of five operational scenarios reveals that the optimally oversized Volt-Var scheme is the most variable solution. The optimization successfully maintains the network lowest total daily operational cost with zero active power curtailment. Consequently, this strategy resolves overvoltage issues while maximizing grid reliability and renewable energy efficiency.

Kata Kunci : Inverter oversizing, voltage rise, PV penetration, reactive power control, distribution network

  1. S1-2026-503496-abstract.pdf  
  2. S1-2026-503496-bibliography.pdf  
  3. S1-2026-503496-tableofcontent.pdf  
  4. S1-2026-503496-title.pdf