Perancangan Sistem Busbar Differential Protection Low-Impedance pada Gardu Induk 150 kV Kentungan

Delia Nurhidayah, Ir. Muhammad Arrofiq, S.T., M.T., Ph.D., IPM

2026 | Tugas Akhir | D4 TEKNOLOGI REKAYASA ELEKTRO

Gangguan pada busbar gardu induk berpotensi menyebabkan terputusnya penyaluran daya pada area yang luas karena seluruh bay yang terhubung ke busbar turut terdampak. Gardu Induk 150 kV Kentungan saat ini belum dilengkapi sistem busbar differential protection, sehingga diperlukan kajian perancangan sebagai dasar implementasinya. Penelitian ini bertujuan menganalisis kesesuaian spesifikasi Current Transformer (CT), merancang sistem busbar differential protection low-impedance, memodelkan zona proteksi, menentukan parameter setting relai diferensial, serta memverifikasi karakteristik operasi sistem melalui simulasi. Metode yang digunakan meliputi evaluasi CT eksisting terhadap SPLN T3.003-1:2011, penentuan setting relai berdasarkan Pedoman Proteksi Transmisi dan Gardu Induk Jawa Bali serta manual relai NR Electric PCS-915SC, pemodelan zona proteksi berdasarkan status disconnecting switch tiap bay, dan simulasi pada DIgSILENT PowerFactory sesuai standar IEC 60909 untuk kondisi normal, gangguan internal, dan gangguan eksternal pada jenis gangguan tiga fasa dan satu fasa ke tanah. Hasil analisis menunjukkan hanya 3 dari 12 bay yang CT eksistingnya memenuhi persyaratan kelas akurasi dan burden, sehingga bay lainnya disesuaikan menjadi CT rasio 2000/1 A kelas 5P20. Parameter setting relai yang diperoleh meliputi arus kerja 0,3 p.u., breakpoint 1 dan 2 masing-masing 2 p.u. dan 8 p.u., slope 1 sebesar 30%, slope 2 sebesar 50%, dan waktu kerja instantaneous. Hasil simulasi menunjukkan relai bekerja selektif, memberikan perintah trip hanya pada zona yang mengalami gangguan internal, serta tetap stabil pada kondisi normal maupun gangguan eksternal. Dengan demikian, rancangan sistem yang dihasilkan telah memenuhi karakteristik operasi proteksi busbar yang diharapkan. Penelitian ini memberikan kontribusi berupa rancangan awal sistem proteksi busbar sebagai acuan teknis bagi PT PLN (Persero) dalam implementasi busbar differential protection pada GI 150 kV Kentungan, sekaligus bermanfaat meningkatkan keandalan penyaluran tenaga listrik dan meminimalkan dampak gangguan busbar terhadap kontinuitas operasi sistem.

Faults on a substation busbar can interrupt power delivery over a wide area, since every bay connected to the busbar is affected simultaneously. The 150 kV Kentungan Substation is not yet equipped with a busbar differential protection system, so a design study is required as a basis for its implementation. This study aims to analyze the suitability of the existing Current Transformer (CT) specifications, design a low-impedance busbar differential protection system, model the protection zones, determine the differential relay setting parameters, and verify the system's operating characteristics through simulation. The method includes evaluating the existing CTs against SPLN T3.003-1:2011, determining relay settings based on the PLN Jawa-Bali Transmission and Substation Protection Guideline and the NR Electric PCS-915SC relay manual, modeling protection zones based on each bay's disconnecting switch status, and simulating the system in DIgSILENT PowerFactory in accordance with IEC 60909 under normal, internal-fault, and external-fault conditions for three-phase and single line-to-ground faults. The results show that only 3 of the 12 bays' existing CTs meet the required accuracy class and burden, so the remaining CTs were adjusted to a 2000/1 A ratio with 5P20 accuracy class. The resulting relay settings comprise a 0.3 p.u. pickup current, breakpoints 1 and 2 of 2 p.u. and 8 p.u., slope 1 of 30\%, slope 2 of 50\%, and an instantaneous time setting. The simulation results show that the relay operates selectively, issuing a trip command only for the zone experiencing an internal fault, while remaining stable under normal operation and external faults. The designed protection system therefore meets the expected busbar protection operating characteristics. This study contributes a preliminary design of the busbar protection system as a technical reference for PT PLN (Persero) in implementing busbar differential protection at the 150 kV Kentungan Substation, and is expected to improve power delivery reliability and minimize the impact of busbar faults on system operating continuity.

Kata Kunci : busbar differential protection, current transformer, DIgSILENT PowerFactory, low-impedance, zona proteksi

  1. D4-2026-499398-abstract.pdf  
  2. D4-2026-499398-bibliography.pdf  
  3. D4-2026-499398-tableofcontent.pdf  
  4. D4-2026-499398-title.pdf