Laporkan Masalah

ANALISIS SYNTHETIC INERTIA (SI) PADA VSC-HVDC UNTUK MENINGKATKAN KEANDALAN DAN INTEGRASI ENERGI TERBARUKAN DI SISTEM TENAGA LISTRIK

Azriel Sakti Raja Manihuruk, Ir. Roni Irnawan, , S.T., M.Sc., Ph.D., SMIEEE.

2026 | Skripsi | TEKNIK ELEKTRO

Penetrasi Energi Baru Terbarukan (EBT) seperti Pembangkit Listrik Tenaga Bayu (PLTB) secara masif berdampak pada penurunan inersia alami sistem mekanis, yang berisiko memicu ketidakstabilan frekuensi jaringan. Penelitian ini bertujuan untuk menganalisis penerapan Synthetic Inertia (SI) pada transmisi VSC-HVDC guna meningkatkan keandalan sistem, serta menentukan nilai parameter konstanta inersia (H) yang paling optimal berdasarkan kompromi (trade-off ) operasional. Metodologi yang digunakan adalah simulasi time-domain dengan memvariasikan konstanta inersia (H = 2, 4, 8, 12 detik dan SI OFF) pada tiga skenario gangguan ekstrem: pelepasan unit pembangkit (switch event), penambahan beban kejut 12% (load step event), dan fluktuasi intermitensi PLTB. Hasil penelitian menunjukkan bahwa aktivasi SI mampu meredam Laju Perubahan Frekuensi (RoCoF) secara signifikan di seluruh skenario pengujian. Namun, kompensasi daya instan ini berdampak pada pengurasan tegangan kapasitor DC-link (Vdc) dan lonjakan arus saluran. Melalui analisis komparatif, penyetelan H = 8 detik teridentifikasi sebagai parameter optimal karena mampu memberikan redaman frekuensi yang superior tanpa memicu saturasi termal arus konverter maupun anomali pada Phase-Locked Loop (PLL). Kesimpulan dari penelitian ini adalah integrasi kendali Synthetic Inertia pada VSC-HVDC terbukti efektif bertindak sebagai peredam guncangan transien (shock absorber), yang secara bersamaan mampu meningkatkan stabilitas frekuensi AC dan mempertahankan batas aman operasional sirkuit transmisi DC.

The massive penetration of Renewable Energy Sources (RES) such as Wind Power Plants impacts the reduction of natural inertia in mechanical systems, which risks triggering grid frequency instability. This study aims to analyze the implementation of Synthetic Inertia (SI) on VSC-HVDC transmission to improve system reliability, and to determine the optimal inertia constant parameter (H) based on operational tradeoffs. The methodology used is time-domain simulation by varying the inertia constant (H = 2, 4, 8, 12 seconds and SI OFF) across three extreme disturbance scenarios: generator tripping (switch event), a 12% sudden load addition (load step event), and wind intermittency fluctuation. The results show that SI activation significantly dampens the Rate of Change of Frequency (RoCoF) across all testing scenarios. However, this instantaneous power compensation impacts the depletion of the DC-link capacitor voltage (Vdc) and causes line current surges. Through comparative analysis, the H = 8 seconds setting was identified as the optimal parameter because it provides superior frequency damping without triggering thermal saturation of the converter current or anomalies in the Phase-Locked Loop (PLL). The conclusion of this study is that the integration of Synthetic Inertia control on VSC-HVDC is proven effective as a transient shock absorber, simultaneously improving AC frequency stability and maintaining the safe operational limits of the DC transmission circuit.

Kata Kunci : VSC-HVDC, inersia sintetis, stabilitas frekuensi, integrasi energi terbarukan, respons transien

  1. S1-2026-500292-abstract.pdf  
  2. S1-2026-500292-bibliography.pdf  
  3. S1-2026-500292-tableofcontent.pdf  
  4. S1-2026-500292-title.pdf