Dampak Ketidakpastian Integrasi Fotovoltaik dan Stasiun Pengisian Kendaraan Listrik terhadap Aliran Daya Probabilistik dengan Point Estimate Method 2m+1

Fahmi Ahmad Aryanto, Dr. Ir. Jimmy Trio Putra, S.T., M.Eng., IPM.

2026 | Tugas Akhir | D4 TEKNOLOGI REKAYASA ELEKTRO

Transformasi sistem energi nasional mendorong peningkatan penetrasi photovoltaic (PV) sebagai pembangkit terdistribusi pada jaringan distribusi tenaga listrik. Selain itu, pertumbuhan electric vehicle charging station (EVCS) turut meningkat sebagai beban dinamis pada sistem yang sama. Integrasi PV sebagaiĀ  pembangkit terdistribusi dan EVCS sebagai beban dinamis menimbulkan ketidakpastian yang dapat memengaruhi kualitas operasi sistem distribusi tenaga listrik. Penelitian ini bertujuan menganalisis pengaruh ketidakpastian PV dan EVCS terhadap profil tegangan dan rugi-rugi daya pada Penyulang Jajar 02 PLN UP3 Surakarta menggunakan metode Probabilistic Load Flow berbasis Point Estimate Method (PEM) 2m+1. Validasi metode dilakukan menggunakan sistem uji IEEE 33-Bus. Pemodelan dilakukan terhadap variabel acak beban pelanggan, pembangkitan PV, dan beban EVCS dengan mempertimbangkan korelasi antarvariabel. Simulasi dilaksanakan pada beberapa skenario integrasi DER dan dievaluasi menggunakan metode Backward-Forward Sweep untuk memperoleh parameter statistik tegangan dan rugi-rugi daya. Hasil penelitian menunjukkan bahwa EVCS merupakan faktor yang paling dominan dalam memengaruhi kinerja sistem. Peningkatan beban EVCS menyebabkan penurunan tegangan, peningkatan pembebanan saluran, dan kenaikan rugi-rugi daya, sedangkan integrasi PV memberikan dampak sebaliknya melalui perbaikan profil tegangan dan pengurangan rugi-rugi daya. Analisis probabilistik juga mengidentifikasi beberapa bus ujung penyulang sebagai lokasi yang paling rentan terhadap kondisi undervoltage. Selain itu, hasil analisis sensitivitas menunjukkan bahwa kapasitas dan lokasi EVCS memiliki pengaruh yang lebih besar dibandingkan kapasitas PV terhadap kualitas operasi sistem. Berdasarkan hasil validasi pada Penyulang Jajar 02 dan sistem IEEE 33-Bus, metode PEM 2m+1 mampu merepresentasikan ketidakpastian PV dan EVCS secara efektif dengan kebutuhan komputasi yang relatif efisien. Metode ini dapat digunakan sebagai alat analisis dalam Probabilistic Load Flow pada sistem distribusi dengan penetrasi sumber daya energi terdistribusi yang tinggi.

The transformation of the national energy system is driving increased penetration of photovoltaic (PV) as distributed generation in the electricity distribution network. In addition, the growth of electric vehicle charging stations (EVCS) is also increasing as a dynamic load within the same system. The integration of PV as distributed generation and EVCS as dynamic loads introduces uncertainties that may affect the operational performance of electric power distribution systems. This study aims to analyze the impact of PV and EVCS uncertainties on voltage profiles and power losses in the Jajar 02 Feeder of PLN UP3 Surakarta using the Probabilistic Load Flow (PLF) method based on the Point Estimate Method (PEM) 2m+1. The method was validated using the IEEE 33-Bus test system. The modeling process considers random variables associated with customer loads, PV generation, and EVCS loads while incorporating correlations among these variables. Simulations were conducted under several distributed energy resource (DER) integration scenarios and evaluated using the Backward-Forward Sweep method to obtain statistical parameters of voltage and power losses. The results indicate that EVCSs are the most dominant factor affecting system performance. An increase in EVCS load leads to voltage drops, higher line loading, and increased power losses, whereas PV integration provides the opposite effect by improving voltage profiles and reducing power losses. Probabilistic analysis also identifies several buses located at the end of the feeder as the most vulnerable locations to undervoltage conditions. Furthermore, the sensitivity analysis reveals that EVCS capacity and placement have a greater influence on system operational performance than PV capacity. Based on the validation results obtained from both the Jajar 02 Feeder and the IEEE 33-Bus system, the PEM 2m+1 is capable of effectively representing PV and EVCS uncertainties with relatively efficient computational requirements. Therefore, the method can be considered a viable alternative for Probabilistic Load Flow analysis in distribution systems with high penetration levels of distributed energy resources.

Kata Kunci : Electric Vehicle Charging Station, Photovoltaic, Point Estimate Method, Probabilistic Power Flow.

  1. D4-2026-494661-abstract.pdf  
  2. D4-2026-494661-bibliography.pdf  
  3. D4-2026-494661-tableofcontent.pdf  
  4. D4-2026-494661-title.pdf