FPGA-Based Current Control Strategy for Three-Phase Two-Level Voltage Source Inverter (2L-VSI) with Real-Time Simulation Testing

Christofer Steven Pangdefan, Dr.-Ing. Ir. Yohan Fajar Sidik, S.T., M.Eng; Ir. Sigit Basuki Wibowo, S.T., M.Eng., Ph.D., IPM.

2026 | Skripsi | TEKNIK ELEKTRO

Inverter sumber tegangan tiga fasa dua level (2L-VSI) memerlukan lingkar arus dalam (inner current loop) yang cepat dan akurat untuk operasi terhubung jaringan (gridconnected). Skripsi ini mengimplementasikan pengendali arus proportional-integral pada kerangka acuan sinkron (SRF-PI) lingkar tertutup secara lengkap untuk 2L-VSI tiga fasa terhubung jaringan pada Field Programmable Gate Array (FPGA) dan memvalidasinya melalui pengujian simulasi waktu nyata (real-time). Pengendali yang terdiri atas transformasi Clarke dan Park, pembangkitan sudut jaringan berbasis CORDIC, modulasi lebar pulsa sinusoidal (SPWM), serta penyisipan waktu mati (dead-time), diubah ke dalam aritmetika titik tetap (fixed-point) dan dideskripsikan dalam Verilog. Validasi dilakukan secara bertahap, simulasi rangkaian luring pada QSPICE, kemudian pengujian Hardwarein-the-Loop (HIL) waktu nyata, yang mana pengendali FPGA menggerakkan model plant 2L-VSI yang dieksekusi pada Plexim RT Box dengan memperhitungkan latensi pipeline dan antarmuka ADC/DAC yang sebenarnya. Pengujian lingkar terbuka memverifikasi jalur pembangkitan sinyal maju (forward path) dan menghasilkan arus tiga fasa seimbang dengan distorsi harmonik total (THD) orde rendah di bawah 1,3%. Lingkar tertutup kemudian dievaluasi pada dua belas titik operasi yang mencakup referensi arus aktif, reaktif, dan gabungan dari 10 hingga 200 A. Pada simulasi, pengendali melacak referensinya dengan galat keadaan tunak di bawah 0,7?n dekopling dq yang efektif, secara waktu nyata, galat pelacakan tetap di bawah 1,7% (di bawah 0,6% untuk referensi 50 A ke atas), sedangkan THD arus yang diinjeksikan tetap berada dalam batas standar IEEE 519 untuk setiap referensi 50 A ke atas. Hipotesis galat pelacakan keadaan tunak di bawah 5?n THD arus jaringan dalam batas IEEE 519 dengan demikian terkonfirmasi pada rentang operasi praktis, dengan batas hanya terlampaui pada referensi terkecil 10 A ketika kuantisasi titik tetap mendominasi fundamental yang kecil. Penelitian ini menghasilkan implementasi FPGA yang terdokumentasi dan tervalidasi perangkat keras untuk pengendali arus lingkar tertutup pada sistem 2L-VSI terhubung jaringan. 

The three-phase two-level voltage source inverter (2L-VSI) relies on a fast and accurate inner current loop for grid-connected operation. This thesis implements a complete closed-loop synchronous-reference-frame proportional-integral (SRF-PI) current controller for a grid-connected three-phase 2L-VSI on a Field Programmable Gate Array (FPGA) and validates it through real-time simulation testing. The controller, comprising the Clarke and Park transformations, CORDIC-based grid-angle generation, sinusoidal pulse-width modulation (SPWM), and dead-time insertion, is recast in fixed-point arithmetic and described in Verilog. Validation follows a staged program, offline circuit simulation in QSPICE, followed by real-time Hardware-in-the-Loop (HIL) testing in which the FPGA controller drives a 2L-VSI plant model executed on a Plexim RT Box, subject to the actual pipeline latency and ADC/DAC interface. The open-loop tests verify the forward signal-generation path, producing balanced three-phase currents with a low-order total harmonic distortion (THD) below 1.3%. The closed loop is then evaluated over twelve operating points spanning active, reactive, and combined current references from 10 to 200 A. In simulation the regulator tracks its references with a steady-state error below 0.7% and effective dq decoupling, in real time the tracking error stays below 1.7% (below 0.6% for references of 50 A and above), while the injected-current THD remains within the IEEE 519 limit for every reference of 50 A and above. The hypothesis of a steady-state tracking error below 5% and a grid-current THD within IEEE 519 is therefore confirmed across the practical operating range, the limit being exceeded only at the smallest 10 A references where fixed-point quantization dominates the small fundamental. The work delivers a documented, hardware-validated FPGA implementation of a closed-loop current controller for grid-connected 2L-VSI systems. 

Kata Kunci : FPGA, pengendalian arus, inverter sumber tegangan dua level, kerangka acuan sinkron PI, Hardware-in-the-Loop

  1. S1-2026-498810-abstract.pdf  
  2. S1-2026-498810-bibliography.pdf  
  3. S1-2026-498810-tableofcontent.pdf  
  4. S1-2026-498810-title.pdf