Simulasi Pengaruh Saturasi Current Transformer terhadap Overcurrent Relay Berbasis Transient Parameter Sensitivity Analysis Menggunakan MATLAB
Anya Yustin, Ir. Ahmad Adhiim M., S.T., M.Eng., IPM
2026 | Tugas Akhir | D4 TEKNOLOGI REKAYASA ELEKTRO
Keandalan proteksi kelistrikan bergantung pada linieritas CT. Saat gangguan ekstrem, CT mengalami saturasi akibat clipping pada secondary waveform, yang menurunkan true RMS dan menunda trip time OCR sehingga berisiko merusak koordinasi proteksi di lapangan. Penelitian ini bertujuan untuk mengevaluasi tingkat sensitivitas parameter transien terhadap saturasi CT dan deviasi trip time OCR. Penelitian kuantitatif menggunakan metode transient parameter sensitivity analysis melalui pemodelan komputasi perangkat lunak MATLAB/Simulink. Pengumpulan data dieksekusi dengan menyimulasikan berbagai skenario pengujian terhadap variasi parameter fisis, yang mencakup perubahan nilai impedansi burden, spesifikasi turn ratio, injeksi besaran remanent flux, dan rasio X/R pada gangguan asymmetrical current berkomponen DC offset. Hasil simulasi membuktikan kenaikan burden 0,05 ?, 0,6 ?, 2 ?, dan 5 ? mempercepat time to saturation menjadi 0,607 s, 0,55 s, 4,02 ms, dan 3,62 ms, yang menunda trip time dari 0,849 s menjadi 0,874 s, 1,145 s dan 2,189 s. Spesifikasi turn ratio 200/5 A memicu saturasi di 2,55 ms dengan trip time 0,915 s, sedangkan 800/5 A mencatat time to saturation 4,55 ms dan trip time 1,241 s. Injeksi remanent flux 0,8 mempercepat time to saturation ke 3,84 ms. Kenaikan rasio X/R dari 30 ke 50 memperpanjang time constant dari 0,0955 s ke 0,1591 s, mempercepat time to saturation dari 0,51069 s menjadi 0,51048 s, dan menunda trip time dari 1,470 s ke 1,477 s. Skenario ekstrem asymmetrical current dan remanent flux mencatat time to saturation 3,83 ms dengan trip time 1,468 s. Kesimpulannya, gangguan asimetris berfluks sisa dengan burden merupakan penyebab deviasi paling dominan. Oleh karena itu, disarankan untuk meminimalkan burden, menggunakan turn ratio yang tinggi, melakukan degaussing rutin, dan merancang algoritma kompensasi digital.
The reliability of electrical protection heavily depends on CT linearity. During extreme faults, the CT experiences saturation due to secondary waveform clipping, which reduces the true RMS and delays the OCR trip time, thus risking the disruption of protection coordination in the field. This study aims to evaluate the level of transient parameter sensitivity to CT saturation and OCR trip time deviation. This quantitative research uses a transient parameter sensitivity analysis method through computational modeling in MATLAB/Simulink software. Data collection was executed by simulating various test scenarios on physical parameter variations, which include changes in burden impedance, turn ratio specifications, remanent flux injection, and X/R ratio during an asymmetrical current fault with a DC offset component. Simulation results prove that increasing the burden to 0.05 ?, 0.6 ?, 2 ?, and 5 ? accelerates the time to saturation to 0.607 s, 0.55 s, 4.02 ms, and 3.62 ms, respectively, delaying the trip time from 0.849 s to 0.874 s, 1.145 s and 2.189 s. A 200/5 A turn ratio specification triggers saturation at 2.55 ms with a 0.915 s trip time, whereas the 800/5 A records a 4.55 ms time to saturation and a 1.241 s trip time. A 0.8 remanent flux injection accelerates the time to saturation to 3.84 ms. Increasing the X/R ratio from 30 to 50 prolongs the time constant from 0.0955 s to 0.1591 s, accelerating the time to saturation from 0,51069 s to 0,51048 s, and delaying the trip time from 1.470 s to 1.477 s. The extreme scenario of asymmetrical current and remanent flux records a 3.83 ms time to saturation and a 1.468 s trip time. In conclusion, an asymmetrical fault with residual flux combined with the burden is the most dominant cause of deviation. Therefore, it is recommended to minimize the burden, use a high turn ratio, perform routine degaussing, and design digital compensation algorithms.
Kata Kunci : Saturasi Current Transformer, Overcurrent Relay, Parameter Transien, MATLAB/Simulink