Laporkan Masalah

Perancangan Mobile Charging Station Berbasis Panel Surya dan Battery Energy Storage System (BESS) untuk Mendukung Operasi Lapangan Bebas Emisi

Syukron Hani Isromi, Ir. Ahmad Adhiim Muthahhari, S.T., M.Eng., IPM.

2026 | Tugas Akhir | D4 TEKNOLOGI REKAYASA ELEKTRO

Indonesia merupakan salah satu wilayah yang sangat rentan terhadap bencana alam katastrofik yang sering kali melumpuhkan total infrastruktur distribusi kelistrikan kritis. Solusi taktis menggunakan generator set (genset) diesel di posko pengungsian terkendala oleh tingginya emisi gas buang beracun serta risiko kelangkaan BBM akibat terputusnya jalur logistik. Di sisi lain, pemanfaatan sistem cadangan daya konvensional seperti UPS atau power bank berkapasitas besar masih memiliki keterbatasan mobilitas yang signifikan di medan rusak dan pengisian ulangnya mutlak bergantung pada jaringan grid utama. Penelitian ini bertujuan untuk merancang dan menganalisis konfigurasi teknis sistem Mobile Charging Station berbasis PLTS-BESS sebagai solusi penyediaan energi mandiri yang andal, ringkas, dan berkelanjutan. Metode penelitian dilakukan melalui pemodelan dan simulasi menggunakan perangkat lunak simulasi PVSyst, dengan membandingkan karakteristik performa sistem di tiga wilayah dengan profil iklim yang berbeda, yaitu DIY, Aceh, dan Nusa Tenggara Timur (NTT).Hasil penelitian menunjukkan bahwa penerapan strategi penggandaan kapasitas dari kebutuhan minimum secara signifikan mampu meningkatkan traksi keandalan operasional, hingga sanggup menyuplai kebutuhan energi listrik hingga 10 kali lipat dari estimasi rata-rata konsumsi harian rumah tangga. Di wilayah dengan potensi iradiasi tertinggi seperti NTT, konfigurasi sistem mampu memproduksi energi spesifik hingga 42,8 kWh/kWp/day dengan nilai  Performance Ratio (PR) rata-rata tahunan sebesar 71,0%. Sementara itu, pada wilayah dengan intensitas iradiasi terendah seperti Aceh, pasokan daya tetap terjaga optimal pada angka 3,37 kWh/kWp/day dengan capaian PR sebesar 74,1%. Meskipun keberlanjutan produksi daya sangat dipengaruhi oleh dinamika suhu operasional dan fluktuasi iklim setempat, perancangan fisik sistem pada dimensi kontainer 20  feet  ini terbukti memenuhi standar struktural baku, Mobile charging Station ini mampu menghasilkan energi hingga 15339 kWh dengan tidak adanya gas emisi sedangkan generator set dengan kapasitas yang sama menghasilkan 0,802 kg CO2/kWh atau 12.627,18 kg/tahun, penurunan kapasitas memungkinkan untuk diintegrasikan pada Colt Diesel Double untuk fleksibilitas tinggi guna menjangkau area darurat yang terisolasi.

Indonesia is one of the regions most vulnerable to catastrophic natural disasters, which often completely paralyze critical electricity distribution infrastructure. Tactical solutions using diesel generator sets (gensets) at evacuation centers are hampered by high levels of toxic exhaust emissions and the risk of fuel shortages due to disrupted logistics routes. On the other hand, the use of conventional backup power systems such as UPS or large-capacity power banks still has significant mobility limitations in damaged terrain, and their recharging is entirely dependent on the main power grid. This study aims to design and analyze the technical configuration of a Mobile Charging Station system based on a solar PV-BESS as a reliable, compact, and sustainable solution for self-sufficient energy supply. The research method involved modeling and simulation using PVSyst simulation software, comparing the system’s performance characteristics across three regions with different climate profiles Yogyakarta (DIY), Aceh, and East Nusa Tenggara (NTT).The research results show that implementing a strategy of doubling capacity beyond minimum requirements can significantly improve operational reliability, to the point where it can supply up to 10 times the estimated average daily household electricity consumption. In regions with the highest irradiation potential, such as NTT, the system configuration is capable of producing specific energy of up to 42.8 kWh/kWp/day with an average annual Performance Ratio (PR) of 71.0%. Meanwhile, in regions with the lowest irradiation intensity, such as Aceh, power supply remains optimally maintained at 3.37 kWh/kWp/day with a PR of 74.1%. Although the sustainability of power production is significantly influenced by operational temperature dynamics and local climate fluctuations, the physical design of this system housed in a 20-foot container has been proven to meet standard structural requirements. This Mobile Charging Station is capable of generating up to 15,339 kWh with zero gas emissions, whereas a generator set of the same capacity produces 0.802 kg CO2/kWh or 12,627.18 kg/year the reduced size allows for integration into a fleet of Colt Diesel Double vehicles, providing high flexibility to reach isolated emergency areas.

Kata Kunci : Mobile Charging Station, PLTS-BESS, PVSyst, Performance Ratio, Energi Darurat

  1. D4-2026-497149-abstract.pdf  
  2. D4-2026-497149-bibliography.pdf  
  3. D4-2026-497149-tableofcontent.pdf  
  4. D4-2026-497149-title.pdf