UJI KESESUAIAN ANTARA VOLUME MYOMA UTERI BERDASARKAN METODE ELLIPSOID DENGAN VOLUME MYOMA UTERI BERDASARKAN METODE SEGMENTASI VOLUMETRIK PADA MRI PELVIS KONTRAS

Markus Yushan Nandiwardhana, Prof. Dr. dr. Lina Choridah, Sp. Rad., Subsp. PRP (K) ; dr. Wigati Dhamiyati, Sp. Rad., Sp.Onk.Rad. Subsp.Onk.(K)

2026 | Tesis-Spesialis | S2 Radiologi

Latar Belakang: Pengukuran volume myoma uteri merupakan parameter penting dalam evaluasi dan perencanaan terapi. Metode ellipsoid banyak digunakan dalam praktik klinis karena sederhana dan cepat, namun memiliki keterbatasan pada myoma dengan bentuk ireguler. Sebaliknya, metode segmentasi volumetrik berbasis MRI dinilai lebih akurat karena mampu merepresentasikan kontur lesi secara tiga dimensi. Studi komparatif antara kedua metode ini masih terbatas di Indonesia.

Tujuan: Menilai kesesuaian pengukuran volume myoma uteri antara metode ellipsoid dan metode segmentasi volumetrik pada pemeriksaan MRI pelvis kontras.

Metode: Penelitian ini merupakan studi observasional analitik dengan desain potong lintang dan pendekatan retrospektif menggunakan data MRI pelvis kontras di RSUP Dr. Sardjito. Sampel dipilih secara consecutive sampling pada pasien perempuan usia >18 tahun. Pengukuran volume dilakukan secara independen oleh dua dokter spesialis radiologi menggunakan metode ellipsoid dan segmentasi volumetrik. Analisis meliputi deskriptif, uji reliabilitas interobserver (ICC), serta uji kesesuaian menggunakan analisis Bland–Altman.

Hasil: Sebanyak 35 subjek penelitian dianalisis. Uji reliabilitas menunjukkan tingkat kesepakatan yang sangat baik pada kedua metode (ICC >0,99). Analisis kesesuaian menunjukkan adanya perbedaan antara metode ellipsoid dan segmentasi volumetrik, dengan kecenderungan metode ellipsoid memberikan estimasi volume yang lebih rendah, terutama pada myoma dengan morfologi ireguler atau kompleks.

Kesimpulan: Metode ellipsoid dan segmentasi volumetrik memiliki reliabilitas yang sangat baik, namun terdapat perbedaan hasil pengukuran volume. Metode segmentasi volumetrik lebih akurat dalam merepresentasikan volume sebenarnya, terutama pada myoma dengan bentuk tidak teratur, sehingga lebih direkomendasikan pada kasus kompleks.

Background: Measurement of uterine myoma volume is an important parameter in evaluation and treatment planning. The ellipsoid method is widely used in clinical practice due to its simplicity and speed; however, it has limitations in irregularly shaped myomas. In contrast, MRI-based volumetric segmentation is considered more accurate as it can represent the three-dimensional contour of the lesion. Comparative studies between these two methods remain limited in Indonesia.

Objective: To assess the agreement between uterine myoma volume measurements using the ellipsoid method and the volumetric segmentation method on contrast-enhanced pelvic MRI.

Methods: This study was an analytical observational study with a cross-sectional design and retrospective approach using contrast-enhanced pelvic MRI data from Dr. Sardjito General Hospital. Samples were selected using consecutive sampling in female patients aged >18 years. Volume measurements were performed independently by two radiologists using the ellipsoid and volumetric segmentation methods. Data analysis included descriptive analysis, interobserver reliability testing (ICC), and agreement analysis using the Bland–Altman method.

Results: A total of 35 subjects were analyzed. Reliability testing showed excellent agreement for both methods (ICC >0.99). Agreement analysis demonstrated differences between the ellipsoid and volumetric segmentation methods, with a tendency for the ellipsoid method to underestimate volume, particularly in myomas with irreguler or complex morphology.

Conclusion: Both the ellipsoid and volumetric segmentation methods have excellent reliability; however, differences in volume measurements exist. Volumetric segmentation is more accurate in representing the true volume, especially in irregularly shaped myomas, and is therefore recommended for complex cases.

Kata Kunci : Myoma uteri, metode ellipsoid, segmentasi volumetrik, MRI pelvis kontras, volume tumor