ANALISIS PENGARUH GANGGUAN SUSULAN DAN EFEKTIVITAS METODE PENGGANTIAN GAS TERHADAP KEMUNCULAN PRODUK DEKOMPOSISI SO2 DALAM MEDIA ISOLASI SF6 PADA CIRCUIT BREAKER TEGANGAN TINGGI DI PT. PLN (PERSERO)
ARIF SETYAWAN, Prof. Ir. Sarjiya, S.T., M.T., Ph.D., IPU. ; Dr. Ir. M. Isnaeni Bambang Setyonegoro, M.T.
2026 | Tesis | S2 Teknik Elektro
Pemutus tenaga (circuit breaker) dengan media isolasi gas sulfur heksafluorida (SF?) merupakan peralatan vital dalam sistem tenaga listrik. Namun, dekomposisi SF? akibat gangguan listrik menghasilkan produk korosif seperti sulfur dioksida (SO?) yang dapat merusak komponen internal dan menurunkan keandalan peralatan. Penelitian ini bertujuan untuk menganalisis pengaruh gangguan susulan terhadap peningkatan kadar SO? serta kerusakan adsorbent, serta mengevaluasi efektivitas metode penggantian gas dan adsorbent dalam menurunkan kadar SO?. Metode penelitian menggunakan analisis data lapangan dari 32 observasi circuit breaker 150 kV di PT PLN (Persero) periode 2022–2025, dengan pendekatan statistik deskriptif, uji beda, dan regresi linier berganda. Hasil penelitian menunjukkan bahwa gangguan susulan terbukti sebagai faktor dominan dengan rata-rata SO? 95,50 ppmv pada gangguan susulan dibandingkan 23,88 ppmv pada gangguan tunggal (p = 0,00). Model regresi mengonfirmasi koefisien gangguan susulan (?? = 99,99) jauh lebih besar dibandingkan arus gangguan pada gangguan tunggal (?? = -2,38). Sehingga besarnya arus gangguan secara tunggal tidak dominan terhadap peningkatan kadar SO? (koefisien korelasi r = -0,23, R² = 5,32%). Pada gangguan tunggal penggantian gas saja efektif untuk menurunkan kadar SO?. Akan tetapi jika dideteksi kadar SO? tinggi setelah terjadi gangguan susulan maka prosedur pemeliharaan yang paling efektif adalah dengan penggantian gas berikut penggantian adsorbent. Hal ini karena adsorbent berperan sebagai variabel moderator yang mengubah efektivitas tindakan pemeliharaan. Penggantian gas SF? tanpa disertai penggantian adsorbent hanya mampu menurunkan rata-rata konsentrasi SO? dari 85,94 ppmv menjadi 17,94 ppmv, sedangkan penggantian gas yang disertai penggantian adsorbent terbukti sangat efektif, mampu menurunkan konsentrasi SO? hingga mencapai 0 ppmv. Koefisien interaksi antara adsorbent dan gangguan susulan (??=-24,13) menunjukkan adsorbent jenuh memperbesar peningkatan SO? akibat gangguan susulan. Temuan ini memberikan dasar ilmiah untuk pengembangan strategi pemeliharaan berbasis kondisi yang lebih efektif pada circuit breaker SF?.
Circuit breakers insulated with sulfur hexafluoride (SF?) gas are critical components in electric power systems. However, the decomposition of SF? caused by electrical faults generates corrosive by-products, such as sulfur dioxide (SO?), which can damage internal components and reduce equipment reliability. This study aims to analyze the effect of subsequent fault on increasing SO? levels and adsorbent degradation, as well as to evaluate the effectiveness of gas and adsorbent replacement methods in reducing SO? levels. The research employs field data analysis from 32 observations of 150 kV circuit breakers operated by PT PLN (Persero) during the 2022–2025 period, using descriptive statistical analysis, difference testing, and multiple linear regression. The regression model confirms that the coefficient for secondary faults (??= 99.99) is substantially higher than that for single faults (?1=-2.38). Consequently, the magnitude of the single fault current does not significantly contribute to the increase in SO? levels (correlation coefficient r =-0.23, R2=5.32%). In the case of single faults, gas replacement alone is sufficient to reduce SO? concentrations. However, if high SO? levels are detected following a secondary fault, the most effective maintenance procedure is the combined replacement of both the gas and the adsorbent. This is because the adsorbent acts as a moderating variable that influences the efficacy of the maintenance intervention. Replacing SF6 gas without replacing the adsorbent reduces the mean SO? concentration from 85.94 ppmv to 17.94 ppmv, whereas the combined replacement of both gas and adsorbent is markedly more effective, achieving a reduction in SO? concentration to 0 ppmv. The interaction coefficient between the adsorbent and secondary faults (?5=-24.13) indicates that saturated adsorbent exacerbates the rise in SO? levels resulting from secondary faults. These findings provide a scientific basis for developing more effective condition-based maintenance strategies for SF? circuit breakers.
Kata Kunci : Sulfur Dioksida (SO?), Dekomposisi SF?, Gangguan Susulan, Adsorbent, Pemeliharaan Berbasis Kondisi.