Analisis Kenyamanan Termal pada Bangunan Hunian di Padukuhan Derpoyudan
Ariiq Dzaki Muslim, Dr. Eng. Ir. Mohammad Kholid Ridwan, S.T., M.Sc., IPU., ASEAN Eng.
2025 | Skripsi | FISIKA TEKNIK
Tantangan
kenyamanan termal di hunian Padukuhan Derpoyudan, dengan suhu mencapai 31,8 °C dan kelembapan 79%,
menuntut analisis yang dapat menghubungkan keluhan subjektif penghuni dengan
data lingkungan yang objektif.
Penelitian ini menggunakan metode campuran yang dimulai
dengan survei persepsi subjektif pada 46 rumah untuk memetakan sensasi termal
umum. Tahap selanjutnya adalah studi kasus kuantitatif pada satu rumah, di mana
parameter fisik seperti suhu, mean radiant temperature (MRT), dan kelembapan
diukur dengan sensor. Data ini, digabungkan dengan profil spesifik responden
yakni insulasi pakaian 0,18 clo dan laju metabolisme 1,0 MET, yang kemudian
digunakan untuk menghitung indeks predicted mean vote (PMV) dan predicted
percentage of dissatisfied (PPD) sesuai standar ASHRAE 55.
Hasil survei umum yang menunjukkan mayoritas (57%)
penghuni merasa "panas" divalidasi secara kuantitatif oleh studi
kasus. Pada jam puncaknya yakni pukul 12 WIB, studi kasus menunjukkan PMV +2,4
("Panas") dengan PPD 91,1%. Validasi tercapai melalui keselarasan
antara hasil perhitungan objektif dengan persepsi subjektif responden di waktu
yang sama dengan penlilaian "Panas". Hal ini menunjukkan
kecenderungan ketidakpuasan termal warga Padukuhan Derpoyudan dan membuktikan
bahwa keluhan termal yang dirasakan warga secara luas memiliki dasar kondisi
fisik lingkungan yang nyata.
The
challenge of thermal comfort in the rural residences of Derpoyudan Hamlet, with
temperatures reaching 31.8 °C and humidity at 79%, demands an
analysis that can connect the occupants' subjective complaints with objective
environmental data.
This
research uses a mixed-method approach, beginning with a subjective perception
survey in 46 houses to map the general thermal sensation. The next stage is a
quantitative case study in one house, where physical parameters such as temperature,
mean radiant temperature (MRT), and humidity were measured with sensors. This
data, combined with the specific profile of the respondent, namely, clothing
insulation of 0.18 clo and a metabolic rate of 1.0 MET, was then used to
calculate the predicted mean vote (PMV) and predicted percentage of
dissatisfied (PPD) indices according to the ASHRAE 55 standard.
The
general survey results, which showed a majority (57%) of occupants feeling
"hot," were validated quantitatively by the case study. At its peak
time at 12 p.m., the case study showed a PMV of +2.4 ("Hot") with a
PPD of 91.1%. Validation was achieved through the alignment between the
objective calculation results and the respondent's subjective perception at the
same time, which was rated as "Hot". This indicates a tendency of
thermal dissatisfaction among the residents of Derpoyudan Hamlet and proves that
the widely felt thermal complaints have a basis in real physical environmental
conditions.
Kata Kunci : kenyamanan termal, preferensi termal, studi lapangan, PMV, PPD