Rancang bangun Single Channel analyzer untuk sistem tomografi komputer

SAPUAN, Imam, Gede Bayu Suparta, Ph.D

2004 | Tesis | S2 Ilmu Fisika

Rancang bangun single channel Analyzer (SCA) untuk sistem tomografi komputer telah dilakukan. Rancang bangun sistem meliputi unit amplifier, unit pembentukan pulsa detektor, unit pencacah dan unit kendali SCA, serta perangkat lunak pengendali dan pengolah datanya. Kinerja hasil rancang bangun kemudian diuji berdasarkan kinerja spektroskopi dan kinerjanya ketika diterapkan untuk sistem tomografi komputer (STK). Dengan SCA rakitan ini, prosedur spektroskopi yang merupakan prosedur awal yang penting dalam proses tomografi dapat dilakukan secara otomatis dan singkat, sekaligus definisi jangkauan tenaga radiasi yang dipakai dapat lebih tepat dan akurat. Kinerja berdasarkan prosedur spektrometer-g diuji berdasarkan resolusi detektor dan resolusi sistem spektrometer-g pada full width at half maximum (FWHM), dengan pembanding kinerja SCA ORTEC™. Resolusi detektor NaI(Tl) dengan SCA ORTEC™ adalah (10,4 ± 0,7)%, sedangkan dengan SCA rakitan adalah (12,04 ± 0,05)%, dengan sumber Cs-137. Resolusi sistem spektrometer-g dengan SCA ORTEC™ terhadap Co-60 adalah (42,4 ± 0,7) keV, sedangkan dengan SCA rakitan adalah (43,3 ± 0,2) keV. Uji kinerja melalui prosedur tomografi komputer telah dilakukan. Sinogram hasil pemayaran terhadap obyek segitiga bahan timbal diperoleh dari kedua sistem tomografi komputer (STK) tersebut. Data sinogram yang diperoleh direkonstruksi menggunakan metode penjumlahan proyeksi balik terkonvolusi. Hasil rekonstruksi citra dari proses pemayaran dengan kedua STK tersebut secara visual sama.

Design and construction of a single channel Analyzer (SCA) for a computed tomography system has been accomplished. The system included amplifier unit, detector pulse shapping unit, counter unit and control unit, along with its control and data processing software. The performance of the system was tested based on spectroscopy and its implemetation on a computed tomography system. Using this SCA, the spectroscopy procedure as one important step in tomography can be done automatically and quickly, and so the energy range being used can be well-defined. The performance on the g-spectroscopy are tested based on the detector resolution and the g-spectrometer sistem resolution at full width at half maximum (FWHM), with unit from SCA ORTEC™ as a comparator. The resolution of detector NaI(Tl) with SCA ORTEC™ was (10,4 ± 0,7)%, while using this SCA was (12,04 ± 0,05)%, when using isotope Cs-137. The resolution of g-spectrometer system with SCA ORTEC™ toward Co-60 was (42,4 ± 0,7) keV, while with this SCA was (43,3 ± 0,2) keV. The performance testing through computed tomography procedure also has been done. Some sinograms of a triangle object made of lead have been obtained for both systems. The sinograms were then reconstructed using the summation convolved back-projection method. Visually, the results has no significant differences between each other.

Kata Kunci : Fisika Citra,Tomografi Komputer,Single Channel Analyzer, single channel analyzer, spectroscopy, computed tomography.


    Tidak tersedia file untuk ditampilkan ke publik.