Evaluasi Dosis Efektif di Sekitar Perisai Radiasi Reaktor GAMA-AHR dengan Metode Monte Carlo Menggunakan PHITS 3.341
Ursula Krisna Utaminingtyas Setyo Asih, Prof. Dr. Ir. Andang Widi Harto, M.T., IPU; M. Arif Efendi, S.Si., M.Sc., Ph.D.
2025 | Skripsi | TEKNIK NUKLIR
GAMA-AHR merupakan reaktor yang dikembangkan oleh Tim Riset Reaktor Nuklir, UGM. Reaktor ini memiliki daya termal 200 kWth dan mampu menghasilkan sekitar 2.500 six-day Ci 99Mo per minggu. Analisis parameter neutronik telah dilakukan, tetapi belum dilakukan evaluasi dosis efektif di sekeliling reaktor untuk memenuhi aspek safety. Dosis efektif harus berada di bawah pembatas dosis yang ditetapkan BAPETEN, yaitu 5 µSv/jam. Sehingga, perlu dilakukan evaluasi laju dosis efektif di sekitar perisai radiasi. Evaluasi dilakukan dengan simulasi Monte Carlo menggunakan perangkat lunak PHITS versi 3.341. Geometri reaktor dimodelkan sesuai desain Tim Riset Reaktor Nuklir dengan perisai radiasi berbahan beton. Dosis efektif dihitung pada empat titik di sekitar reaktor: atas, bawah, dan dua titik di samping reaktor. Simulasi dilakukan pada kondisi burn-up tertinggi, yaitu tahun ke-20. Desain awal dengan ketebalan beton 1 meter belum cukup untuk menurunkan dosis efektif di bagian bawah dan samping reaktor di bawah batas 5µSv/jam. Setelah optimasi, diperoleh bahwa ketebalan beton minimal yang memenuhi regulasi BAPETEN adalah 2,2 meter di bagian bawah dan 2,6 meter di sekeliling reaktor. Dosis efektif terukur di bagian bawah dan kedua titik di samping reaktor berturut-turut 3,28 µSv/jam; 3,34 µSv/jam; dan 4,63 µSv/jam. Dengan ini, perisai radiasi reaktor dinyatakan aman dan memenuhi prinsip keselamatan radiasi.
GAMA-AHR is a reactor developed by UGM’s Nuclear Reactor Research Team. This reactor has a thermal power of 200 kWth and produces approximately 2,500 six-day Ci of 99Mo per week. Although neutronic analysis has been conducted, effective dose evaluation has not yet been performed. The effective dose must remain below BAPETEN’s 5 µSv/hour dose limit. An evaluation of the effective dose rate around the shielding is necessary. The evaluation was done through Monte Carlo simulations using PHITS 3.341 software. The reactor geometry was modeled according to the design developed by the Nuclear Reactor Research Team. The effective dose was calculated at four points around the reactor: above, below, and two points on the sides. The simulation was performed under maximum burn-up, in year 20. The initial 1-meter concrete shield design was insufficient to reduce the dose below 5 µSv/h at the bottom and sides. After optimization, the minimum concrete thickness that meets BAPETEN’s dose limit is 2.2 meters at the bottom and 2.6 meters around the reactor. The measured effective doses at the bottom and two side points were 4.63 µSv/hour, 3.28 µSv/hour, and 3.34 µSv/hour, respectively. The shielding is considered safe and compliant with radiation protection principles.
Kata Kunci : GAMA-AHR, dosis efektif, PHITS, perisai radiasi, Monte Carlo