Syringe Solid-Phase Extraction for Pb(II) and Cu(II) in Milk Using Alginate-Chitosan-PVA and Alginate-Activated Carbon-PVA Adsorbents: Method Development and Application
Ahmad Akhib Ainul Yaqin, Prof. Drs. Dwi Siswanta, M.Eng., Ph.D.; Prof. Suherman, S.Si., M.Sc., Ph.D.
2025 | Disertasi | S3 Ilmu Kimia
Susu dapat mengandung logam
toksik pada konsentrasi yang sangat rendah seperti Pb(II) dan Cu(II) yang
berasal dari paparan lingkungan atau kontaminasi selama proses produksi. Namun,
penentuan langsung menggunakan FAAS menjadi sulit karena kompleksitas matriks
susu dan konsentrasi analit yang rendah. Metode syringe SPE menawarkan
pendekatan prekonsetrasi yang sederhana, cepat, dan efektif untuk meningkatkan
sensitivitas dan selektivitas deteksi ion logam tersebut.
Penelitian ini mengembangkan
dan mengoptimasi metode syringe SPE menggunakan dua adsorben
termodifikasi, yaitu kitosan–alginat–PVA (CAP) dan alginat–karbon–PVA (ACP)
untuk prekonsentrasi serta penentuan ion Pb(II) dan Cu(II) dalam berbagai
sampel susu. Kebaruan metode ini terletak pada penggunaan faktor prekonsetrasi
yang tinggi sehingga meningkatkan sensitivitas dan akurasi analisis logam berat
dalam matriks susu yang kompleks.
Adsorben CAP dan ACP berhasil
disintesis dan dikarakterisasi menggunakan berbagai teknik. CAP dikarakterisasi
dengan FTIR, SEM–EDX, dan XPS, sedangkan ACP dikarakterisasi dengan FTIR,
SEM–EDX, XPS, dan SAA–BET. Beberapa parameter seperti pH, massa adsorben,
siklus sampel dan eluen, konsentrasi HNO3 sebagai eluen, dan faktor
prekonsetrasi dievaluasi menggunakan metode konvensional OVAT. Selektivitas dan
daya guna ulang juga diuji pada kondisi parameter optimal. Optimasi dengan CCD
untuk CAP dan BBD untuk ACP dibandingkan dengan metode optimasi konvensional.
Validasi metode syringe SPE dilakukan dengan membandingkan hasil analit
target yang diperoleh terhadap konsentrasi dari bahan CRM ERM–BD151 berdasarkan
persentase recovery.
Berdasarkan hasil
karakterisasi, adsorben CAP didominasi oleh gugus –COOH, –OH, dan –NH2,
sedangkan ACP didominasi oleh gugus –COOH dan –OH dengan keberadaan pori (1,5–2,5
nm) pada permukaannya. Hasil optimasi syringe SPE dengan adsorben CAP
menunjukkan kondisi optimal pH 5,0 untuk Pb(II) dan pH 4,0 untuk Cu(II), massa
CAP 100 mg, siklus sampel dan eluen sebanyak 5 kali, konsentrasi HNO3
2 M, dan faktor prekonsetrasi 100 kali lipat. Untuk ACP, kondisi optimal yaitu
pH 5,0 untuk Pb(II) dan pH 4,0 untuk Cu(II), massa ACP 75 mg, 4 siklus sampel,
9 siklus eluen untuk Pb(II), dan 8 siklus eluen untuk Cu(II), konsentrasi HNO3
1 M, serta faktor prekonsetrasi 100 kali lipat. CAP menunjukkan selektivitas
sangat tinggi (sekitar 90–99%) pada kondisi optimal dan dapat digunakan ulang
hingga 3 siklus adsorpsi-desorpsi. ACP juga memiliki selektivitas tinggi
(sekitar 90–99%) dan dapat digunakan ulang hingga 8 siklus.
Optimasi CCD pada CAP
menghasilkan kondisi adsorpsi Pb(II) optimal pada pH 5,0–5,4 dengan massa CAP
100–150 mg. Desorpsi Pb(II) optimal dengan 5 siklus eluen dan konsentrasi HNO3
1,9–2,1 M. Untuk Cu(II), kondisi adsorpsi optimal pada pH 4,3 dan massa CAP
sekitar 105 mg, sedangkan desorpsi optimal dengan 5 siklus eluen dan
konsentrasi HNO3 2,0 M. Optimasi BBD pada ACP menunjukkan kondisi
adsorpsi Pb(II) optimal pada pH 4,7 dengan massa ACP 90 mg dan 3 siklus sampel.
Desorpsi Pb(II) optimal dengan 9 siklus eluen dan konsentrasi HNO3
1,0 M, menghasilkan faktor prekonsetrasi 97 kali lipat. Untuk Cu(II), kondisi
adsorpsi optimal pada pH 4,1, massa ACP 68 mg, dan 4 siklus sampel, sedangkan
desorpsi optimal dengan 4 siklus eluen menggunakan HNO3 1,4 M,
menghasilkan faktor prekonsetrasi 81 kali lipat. Hasil optimasi ini sebanding
dengan metode konvensional.
Validasi dengan CRM ERM–BD151
menunjukkan nilai recovery untuk CAP sebesar 96,2% untuk Pb(II) dan
95,4% untuk Cu(II), serta untuk ACP masing-masing 97,6?n 98,9%.
Setelah validasi, metode
syringe SPE digunakan untuk analisis sampel susu bubuk dengan adsorben CAP,
menghasilkan nilai recovery Pb(II) antara 90,0%–98,4?n Cu(II) antara
90,8%–97,8%. Untuk sampel susu cair menggunakan ACP, recovery Pb(II) dan Cu(II)
masing-masing berkisar antara 90,2%–98,3?n 91,5%–99,2%. Hasil ini
menunjukkan bahwa metode syringe SPE dengan adsorben CAP atau ACP sangat akurat
untuk prekonsentrasi Pb(II) dan Cu(II) dalam berbagai sampel susu.
Pengembangan teknik preparasi sampel yang efisien tetap penting dalam analisis logam pada konsentrasi yang sangat rendah, terutama pada matriks makanan kompleks seperti susu. Kemajuan dalam desain adsorben dan metode ekstraksi akan terus meningkatkan akurasi analisis, pemantauan keamanan, dan regulasi dalam pengendalian mutu pangan.
Milk may
contain trace levels of toxic metals such as Pb(II) and Cu(II), originating
from environmental exposure or contamination during production. However, their
direct determination using flame atomic absorption spectroscopy (FAAS) is
limited by the complexity of the milk matrix and low analyte concentrations.
Syringe solid phase extraction (SPE) provides a simple, rapid, and effective preconcentration
approach to enhance detection sensitivity and selectivity for these metal ions.
This study developed and optimized a syringe solid-phase extraction (SPE)
method using two modified adsorbents, chitosan–alginate–PVA (CAP) and
alginate–carbon–PVA (ACP), to preconcentrate and determine Pb(II) and Cu(II)
ions in various milk samples. The novelty of this method comes from its high
preconcentration factor, which significantly enhances the sensitivity and
accuracy of heavy metal analysis in complex milk matrices.
CAP and ACP
adsorbents were successfully synthesized and characterized using various
techniques. CAP was characterized by FTIR, SEM–EDX, and XPS, while ACP
was characterized by FTIR, SEM–EDX, XPS, and SAA–BET. Several parameters were
evaluated based on conventional one-variable-at-a-time (OVAT): pH, adsorbent
mass, sample and eluent cycles, HNO3 concentration as the eluent,
and preconcentration factors. Additionally, selectivity and reusability were
also tested under optimal parameter conditions. Optimization based on Central
Composite Design (CCD) for CAP and Box Behnken Design (BBD) for ACP was compared
with conventional optimization methods. Subsequently, syringe SPE validation
was conducted by comparing the target analyte values with the certified
reference material (CRM) ERM–BD151 values in response to recovery percentages.
Based on the characterization results, the CAP adsorbent was
generally dominated by –COOH, –OH, and –NH2 groups, while the ACP
adsorbent was dominated by –COOH and –OH groups, with pores (1.5 nm to 2.5 nm)
present on the surface of the adsorbent. The optimization results of the SPE
syringe with CAP adsorbent showed an optimal pH of 5.0 for Pb(II) and pH 4.0
for Cu(II), CAP mass of 100 mg, sample and eluent cycles of 5, HNO3
concentration of 2 M, and preconcentration factor of 100 times. The optimized
with ACP adsorbent, it was at pH 5.0 for Pb(II) and pH 4.0 for Cu(II), ACP mass
of 75 mg, 4 sample cycles, 9 eluent cycles for Pb(II), and sample–eluent cycles
8 for Cu(II), HNO3 concentration of 1 M, and a preconcentration
factor of 100 times. CAP also exhibited very high selectivity (around 90-99%)
under optimal parameter conditions and could be reused up to 3 times in
adsorption-desorption cycles. Meanwhile, ACP also demonstrated very high
selectivity (around 90-99%) under optimal conditions and could be reused up to
8 times in adsorption-desorption cycles.
CCD optimization with CAP gave optimal conditions for Pb(II)
adsorption were pH 5.0–5.4 and CAP mass of 100–150 mg. Pb(II) desorption occurred best under 5 times
eluent cycle with the HNO3 concentration as eluent ranged from 1.9
to 2.1 M. For Cu(II), the optimal conditions for adsorption were pH 4.3 and a CAP
mass of approximately 105 mg. For Cu(II) desorption, the best eluent cycle was
5 times, and the HNO3 concentration ranged from 2.0 mol/L. Likewise,
the optimal Pb(II) adsorption conditions under a BBD-assisted optimized ACP preparation
were pH 4.7, using 90 mg ACP and 3 sample cycles. For Pb(II) desorption, the
best eluent cycle was 9 times with HNO3 concentration as eluent
ranging from 1.0 M to a yield preconcentration factor of 97 times. For Cu(II),
the optimal adsorption conditions were pH 4.1, requiring 68 mg ACP, and 4
sample cycles. The ideal Cu(II) desorption parameters required 4 elution cycles
using 1.4 M HNO3 yielding a preconcentration factor of 81 times. The
optimization results were similar to those obtained through conventional
optimization.
Validation results with CRM ERM–BD151 for the CAP adsorbent
showed a recovery value of 96.2% for Pb(II) and 95.4% for Cu(II). The Pb(II)
recovery was 97.6% for the ACP adsorbent and 98.9% for Cu(II).
After validation, syringe SPE was used to analyze powdered
milk samples with CAP adsorbent. Pb(II) recovery values ranged from 90.0% to
98.4%, while for Cu(II), the recovery ranged from 90.8% to 97.8%. Meanwhile,
liquid milk samples treated with the ACP-containing SPE syringe showed Pb(II)
and Cu(II) recoveries corresponding to 90.2 to 98.3% and 91.5 to 99.2%. These
results indicate that syringe SPE combined with CAP or ACP is highly
accurate for the preconcentration of Pb(II) and Cu(II) in various milk samples. The development of efficient
sample preparation techniques remains critical in trace metal analysis,
particularly in complex food matrices like milk. Advancements in adsorbent
design and extraction methods will continue to enhance analytical accuracy,
safety monitoring, and regulatory compliance in food quality control.
Kata Kunci : Preconcentration, CAP, ACP Pb(II) and Cu(II)