Pengaruh Lama Perendaman Kawat Busur Nikel Titanium Berpelapis Polytetrafluoroethylene dalam Klorheksidin 0,12% terhadap Korosi dan Gaya Unloading
Dian Noviyanti Agus Imam, drg. Christnawati, M.Kes., Sp.Ort (K); Dr. drg. Sri Suparwitri, SU., Sp.Ort (K)
2024 | Tesis-Spesialis | S2 Ortodonsia
Kawat busur nickel titanium (NiTi) berpelapis polytetrafluoroethylene
(PTFE) digunakan seiring dengan peningkatan permintaan penggunaan peranti
ortodonti estetik. Ortodontis merekomendasikan penggunaan klorheksidin 0,12%
selama perawatan ortodonti berlangsung. Penelitian ini bertujuan untuk mengetahui pengaruh lama perendaman
kawat busur NiTi berpelapis PTFE diameter 0,014” dalam klorheksidin 0,12%
selama 1, 7 dan 14 hari terhadap pelepasan ion nikel dan gaya unloading.
Masing-masing sebanyak 36 kawat busur NiTi 0,014” berpelapis PTFE dan tanpa pelapis sepanjang 30 mm dibagi menjadi 12 kelompok secara acak yaitu kelompok yang direndam dalam klorheksidin 0,12% dan saliva buatan selama 1, 7 dan 14 hari. Kadar pelepasan ion nikel diukur menggunakan Atomic Absorption Spectrophotometry (AAS) dan gaya unloading diukur menggunakan uji 3-point bending menggunakan UTM. Hasil uji kadar pelepasan ion nikel dianalisis menggunakan two-way ANOVA dan post hoc LSD (p<0>unloading dianalisis menggunakan Kruskall-Wallis dan Mann Whitney U (p<0>
Hasil penelitian kadar pelepasan ion nikel
terendah pada seluruh kelompok perlakuan 1 hari perendaman. Kadar pelepasan ion
nikel tertinggi pada kelompok kawat busur NiTi berpelapis PTFE dalam klorheksidin
0,12% selama 14 hari perendaman (0,49 ppm). Gaya unloading terendah pada
kelompok kawat busur NiTi berpelapis PTFE dalam klorheksidin 0,12% selama 14
hari (0,39 N) sedangkan tertinggi pada kelompok kawat busur NiTi tanpa pelapis
dalam saliva buatan selama 1 hari (0,8 N). Hasil penelitian menyimpulkan lama
perendaman kawat busur nikel titanium berpelapis PTFE dalam klorheksidin 0,12%
selama 14 hari meningkatkan pelepasan ion nikel dan menurunkan gaya unloading.
In
response to the growing demand for aesthetically pleasing orthodontic
appliances, nickel-titanium (NiTi) coated polytetrafluoroethylene (PTFE)
archwire are utilized. Orthodontists advise using chlorhexidine 0,12% as part
of orthodontic treatment. This study aims to investigate the effect of
immersing a PTFE-coated NiTi archwire with a diameter of 0,014” in a 0,12%
chlorhexidine solution for durations of 1, 7, and 14 days on the release of
nickel ions and unloading force.
Each of the 36 0,014” NiTi archwire, which was 30 mm long and coated with PTFE or without coating, was randomly assigned to one of 12 groups. These groups were immersed in 0,12% chlorhexidine and artificial saliva for 1, 7, and 14 days. Atomic Absorption Spectrophotometry (AAS) was used for measuring nickel ion release levels, while a 3-point bending test was conducted using UTM to measure unloading forces. The levels of nickel ion release were analyzed using a two-way analysis of variance (ANOVA) and post hoc least significant difference (LSD) test (p<0>
According to the research findings, the
levels of nickel ion release were the lowest across all treatment groups after
1 day of immersion. During a 14-day immersion in 0,12% chlorhexidine, the
PTFE-coated NiTi archwires group exhibited the highest level of nickel ion
release (0,49 ppm). The NiTi archwire group coated with PTFE in 0,12%
chlorhexidine for 14 days had the lowest unloading force (0,39 N), while the
NiTi archwire group without coating in artificial saliva for 1 day had the
highest unloading force (0,8 N). The study found that immersing the
nickel-titanium archwire coated with PTFE in 0,12% chlorhexidine for 14 days
increased nickel ion release and decreased unloading force.
Kata Kunci : kawat busur NiTi, polytetrafluoroethylene (PTFE), klorheksidin 0,12%, pelepasan ion nikel, gaya unloading