Pengaturan tegangan dengan transformator IB dan kapasitor Shunt untuk mengurangi rugi daya nyata pada sistem transmisi
SULTAN, Dr.Ir. Sasongko P. Hadi, DEA
2003 | Tesis | S2 Teknik ElektroFokus penelitian ini adalah pengurangan rugi daya nyata pada saluran transmisi melalui pengaturan tegangan. Proses pengaturan dilakukan dengan menginjeksi daya reaktif VAR kapasitor shunt dan perubahan posisi ratio tap trafo Ibt. Transformator Ibt digunakan untuk mengubah konstanta impedansi yang akan mempengaruhi aliran daya reaktif. Pengaturan tegangan untuk mengurangi rugi daya pada saluran dengan menggunakan transformator Ibt dan kapasitor shunt. Perubahan nilai tegangan berdasarkan perubahan tap transformator Ibt dan pemasangan kapasitor shunt diamati dari hasil studi aliran daya dengan metode Newton-Raphson, yang dieksekusi dengan perangkat lunak fortran power station. Hasil penelitian ini, pada kasus beban ringan di peroleh hasil pengurangan rugi daya aktif mencapai (0.13%) dan pada kasus beban berat dengan skenario pengaturan tegangan yang dimulai kapasitor shunt kemudian transformator Ibt beroperasi atau sebaliknya pengurangan rugi daya masing- masing 32,5% dan 28,2%. Dengan cara ini perbaikan kualitas profil tegangan pada masing-masing bus beban juga di peroleh.
The focus of this research is decreasing real power losses at transmission line by voltage regulation. Process voltage regulation is based on reactive power injection of VAR shunt capacitor and reposition of tap ratio of Ibt transformer. It is important to know that Ibt transformer is to alter impedance constant influencing reactive power stream. Voltage regulation could decrease power losses at line by using Ibt transformer and shunt capacitor. Change of voltage value based on the change of tap Ibt transformer and installation of shunt capacitor perceived from result of power flow study with Newton-Raphson method, executed by software of fortran. power station The result of this research explained that at light load case, reduction of real power losses could be achieved (0.13%) and on the peak load case with voltage regulation scenario started by capacitor of shunt later then Ibt transformer operate or on the contrary the reduction of each power losses is 32,5% and 28,2%. In this way, reparation of voltage profile quality at each load bus is so obtained.
Kata Kunci : Transmisi,Rugi Daya Nyata,Pengaturan Tegangan, voltage regulation, Ibt Transformer, shunt capacitor, Newton- Raphson power flow method and decrease line power losses.