PENGARUH JUMLAH PITCH DAN BESAR TAPER PADA FILE ENDODONTIK KONTINU BERBAHAN NIKEL TITANIUM DENGAN BENTUK PENAMPANG VARIABEL TERHADAP NILAI KELELAHAN SIKLIK (kajian in silico)
YUSTIKA CHRYSANDRA, Dr.drg. Tunjung Nugraheni, M.Kes.,Sp.KG(K); Dr.drg. Wignyo Hadriyanto, M.S.,Sp.KG(K)
2023 | Tesis-Spesialis | S2 Ilmu Konservasi Gigi
Desain geometri
sebuah file endodontik diantaranya adalah bentuk penampang, taper dan
pitch. File endodontik NiTi jenis OneCurve (MicroMega)
memiliki modifikasi dua variasi penampang yaitu double-s shaped dan triple
helix. Berbagai jenis modifikasi dibuat untuk meningkatkan ketahanan file
endodontik NiTi dari fraktur.
Kelelahan siklik adalah faktor yang paling sering menyebabkan patahnya file endodontik.
Tujuan penelitian ini untuk mendapatkan desain yang memiliki ketahanan terhadap
kelelahan siklik yang paling baik dari jumlah pitch dan besar taper pada
file endodontik kontinu berbahan NiTi.
Penelitian ini
menggunakan file OneCurve ukuran 25.06 (MicroMega) kemudian
dilakukan pemindaian dengan MicroCT Scan dan modifikasi desain. Jumlah
modifikasi file adalah sembilan dengan jenis modifikasi yaitu besar taper
4%, 6?n 8% serta jumlah pitch dikurangi tiga, tetap dan ditambah tiga.
Simulasi pengukuran kelelahan siklik dilakukan dengan metode elemen hingga
sebanyak masing-masing tiga kali. Data hasil penelitian dianalisis uji Anava
satu jalur kemudian dilanjutkan dengan LSD.
Hasil uji
statistik menunjukkan bahwa terdapat pengaruh besar taper terhadap nilai
kelelahan siklik. Besar taper 4% pada file endodontik memiliki
nilai kelelahan siklik paling rendah. Kesimpulannya besar taper mempengaruhi
nilai kelelahan siklik pada file endodontik kontinu berbahan nikel
titanium dengan bentuk penampang variabel. Jumlah pitch tidak
menunjukkan pengaruh yang signifikan terhadap nilai kelelahan siklik.
The geometric
design of an endodontic file includes cross sectional shape, taper and pitch. NiTi
endodontic files of OneCurve (MicroMega) is made of two variations cross
sectional shape, that is double-s shaped and triple helix. Various kinds of
modifications were made to increase the resistance of the NiTi endodontic files
from fracture. Cyclic fatigue is the most common factor that caused fracture of
endodontic file. The purpose of this study was to obtain a NiTi endodontic file
design that has the best cyclic resistance value based on its taper size and
number of pitch.
This study used
OneCurve endodontic file size 25.06 (MicroMega) then scanned with MicroCT Scan
and modified the geometric design. The number of file modifications was nine.
Taper size modifications was 4%, 6% and 8%, number of pitch modification was
reduced by three, fixed and added by three. Cyclic fatigue measurement simulations
were carried out using the finite element method three times each. The result
data were analyzed using two-way ANOVA test and then continued with LSD.
The results of
statistic test showed that there was an effect of the size of taper on the
cyclic fatigue values. Endodontic file with size of taper 4% had the lowest
cyclic fatigue value. Conclusion in this research was the taper size affects
the value of cyclic fatigue in continues endodontic file made of nickel
titanium with variable cross section. The number of pitch did not show a
significant effect on the cyclic value.
Kata Kunci : kelelahan siklik, jumlah pitch, besar taper, penampang variabel, file endodontik NiTi, in silico