Laporkan Masalah

Perbedaan jumlah bakteri pada beberapa durasi penggunaan kanul trakeostomi

ANGGA KUSUMA, Dr. dr. Bambang Hariwiyanto, Sp.T.H.T.K.L(K), FICS; dr. Dian Paramita Wulandari, M.Sc., Sp.T.H.T.K.L(K)

2021 | Tesis-Spesialis | ILMU KESEHATAN TELINGA HIDUNG TENGGOROK BEDAH KEPALA DAN LEHER

Latar Belakang: Terdapat beberapa kondisi medis yang membutuhkan prosedur trakeostomi. Kanul trakeostomi dapat digunakan dalam jangka pendek maupun jangka panjang. Kanul trakeostomi sebagai perangkat medis yang indwelling dapat mengalami kolonisasi bakteri. Kolonisasi bakteri pada permukaan perangkat medis dapat menjadi sumber infeksi potensial. Tujuan: Untuk mengetahui perbedaan jumlah bakteri pada beberapa durasi penggunaan kanul trakeostomi. Metode: Penelitian ini merupakan penelitian potong lintang. Kanul trakeostomi dengan berbagai durasi penggunaan yang diperoleh dari prosedur dekanulasi pasien yang sebelumnya menjalani trakeostomi dikirim ke Departemen Mikrobiologi untuk memperoleh data jumlah bakteri. Penelitian dilakukan sejak 23 Juli 2020 sampai dengan 6 Januari 2021. Hasil: Rerata jumlah bakteri pada durasi penggunaan kanul kurang dari 30 hari sebesar 48,5 X10 pangkat 3 CFU/ml. Rerata jumlah bakteri pada durasi penggunaan kanul 30 hari atau lebih sebesar 19.451 x 10 pangkat 3 CFU/ml. Rerata jumlah bakteri pada durasi penggunaan kanul kurang dari 90 hari sebesar 5.931 x 10 pangkat 3 CFU/ml. Rerata jumlah bakteri pada durasi penggunaan 90 hari atau lebih sebesar 22.331 x 10 pangkat 3 CFU/ml. Uji hipotesis menggunakan Mann-Whitney menunjukan terdapat perbedaan jumlah bakteri pada durasi penggunaan 30 hari (p=0,004) dan pada durasi 90 hari (p=0,019) Kesimpulan: Terdapat perbedaan jumlah bakteri pada beberapa durasi penggunaan kanul trakeostomi

Background: There are several medical conditions that require tracheostomy procedure. Tracheostomy cannula can be used in the short or long term. Tracheostomy cannula as an indwelling medical device can be colonized by bacteria. Bacterial colonization on the surfaces of an indwelling device is a potential source of infection. Objective: To determine the difference in bacterial count at several durations of using tracheostomy cannula, Methods: This research was a cross-sectional study. Samples of tracheostomy cannula with several durations of use were obtained from the decannulation procedure on patients who previously underwent tracheostomy and sent to the Department of Microbiology to obtain the data of bacterial count. The research was conducted from July 23, 2020 to January 6, 2021 Results: Mean of bacterial count at duration of using cannula less than 30 days was 48.5 x 10 to the power of 3 CFU/ml, while the mean at duration of using cannula 30 days or more was 19.451 x 10 to the power of 3 CFU/ml. Mean of bacterial count at duration of using cannula less than 90 days was 5.931 x 10 to the power of 3 CFU/ml, while the mean at duration of using cannula 90 days or more was 22.331 x 10 to the power of 3 CFU/ml. Using Mann-Whitney tests, the results showed that there were significant differences in bacterial count at duration 30 days (p=0.004) and in bacterial count at duration 90 days (p=0.019) Conclusion: There were significant differences in bacterial count at several durations of using tracheostomy cannula.

Kata Kunci : bacterial count, colonization, duration of using, tracheostomy

  1. SPESIALIS-2021-420609-abstract.pdf  
  2. SPESIALIS-2021-420609-bibliography.pdf  
  3. SPESIALIS-2021-420609-tableofcontent.pdf  
  4. SPESIALIS-2021-420609-title.pdf