STUDI EKSPERIMENTAL PENGARUH KEDALAMAN PENEKANAN RESUSCITATOR BAG MENGGUNAKAN SISTEM AKTUATOR TERHADAP PERUBAHAN NILAI PRESSURE DAN FLOW DALAM SISTEM VENTILATOR RESUSCITATOR BAG TANPA LUNG DENGAN VARIASI SOLENOID TERBUKA

FEBRIAN WIJAYA, Dr. Adhika Widyaparaga, S.T., M.Biomed.Sc.,

2021 | Skripsi | S1 TEKNIK MESIN

Penelitian mengenai pengaruh kedalaman penekanan Resuscitator Bag ventilator telah dilakukan dalam rangka mengetahui karakterisitk parameter (Flow, Pressure dan Volume). Penelitian ini dilakukan dengan memvariasikan kedalaman penekanan Resuscitator Bag dari rentang 7.5 mm-50 mm untuk setiap kenaikan dengan skala sebesar 2.5 mm. Pada sistem penelitian tidak menggunakan test lung dan variasi solenoid terbuka. Kecepatan aktuator diatur konstan sebesar 2 x 40 mm/s. Pengujian menggunakan Resuscitator Bag untuk proses kompresi sehingga menghasilkan flow rate yang kemudian akan menyuplai udara pada sistem. Aktuator pada sistem alat uji digerakkan oleh motor stepper yang dikombinasikan dengan sistem transmisi belt dan pulley untuk menghasilkan penenakan dua arah yang diatur oleh program Arduino. Eksperimen ini menggunakan dua buah Venturimeter yaitu inlet venturimeter dan outlet venturimeter yang berfungsi untuk membaca nilai flow dan pressure yang kemudian dihubungkan dengan sensor MPX2010DP dan ADC sebagai converter. Hasil yang didapatkan menunjukkan bahwa perubahan kedalaman penekanan akan mempengaruhi karakteristik untuk setiap parameter yang diamati. Semakin dalam penekanan Resuscitator Bag maka nilai flow dan pressure yang dihasilkan akan meningkat.

Research on the effect of pressure depth on Resuscitator Bag ventilator has been carried out in order to determine the characteristic of the parameters (flow, pressure and volume). This research conducted by varying the compression depth of the RESUSCITATOR Bag from a range of 7.5 mm to 50 mm for each increment with a scale of 2.5 mm. The system does not use a test lung and using an open solenoid variation. The actuator speed is set constant at 2 x 40 mm/s. This research used an Resuscitator Bag for the compression process to produce a flow rate which will then supplying air to the system. The actuator used in the equipment system is driven by a stepper motor combined with a belt and pulley transmission system to produce a two-way suppression which is set on the Arduino program. This experiment is using two Venturimeter; inlet venturimeter and outlet venturimeter to read the flow and pressure values which are then connected to the MPX2010DP sensor and ADC as a converter. The results show that the change in the pressure depth will affect the characteristics for each parameter observed. The deeper the RESUSCITATOR Bag pressure is, the value of flow and pressure will increase.

Kata Kunci : Resuscitator bag, solenoid terbuka, kedalaman penekanan, flow, pressure

  1. S1-2021-410368-abstract.pdf  
  2. S1-2021-410368-bibliography.pdf  
  3. S1-2021-410368-tableofcontent.pdf  
  4. S1-2021-410368-title.pdf