PENGARUH LUBANG DAN JARAK SENGKANG PADA KUAT TEKAN KOLOM BETON BERPENAMPANG LINGKARAN

SUTRIZAL HARTAWAN, Dr.-Ing. Ir. Andreas Triwiyono; Dr. Ir. Muslikh, M.Sc., M.Phil.

2021 | Tesis | MAGISTER TEKNIK SIPIL

Kolom merupakan elemen pemikul untuk menjaga kestabilan stuktur khususnya akibat pengaruh beban aksial tekan. Kekuatan tekan kolom dapat ditingkatkan dengan penggunaan sengkang spiral. Tujuan penelitian ini yaitu menguji kolom pendek berpenampang silinder diameter 15 cm dan tinggi 30 cm dengan mutu 29,05 MPa. Penelitian menggunakan variasi kolom terdiri dari 2 jenis benda uji yaitu polos tanpa tulangan dan bersengkang spiral. Penampang kolom adalah solid dan berlubang lingkaran dengan diameter 2,5 cm, diameter 5 cm, dan diamter 7,5 cm. Sengkang spiral digunakan jarak yaitu 2,5 cm, 5 cm, 7,5 cm dan jarak 10 cm. Total benda uji berjumlah 40 buah dan dilakukan pengujian beban tekan aksial hingga keadaan maksimal ataupun hancur. Dari hasil penelitian ini didapatkan bahwa pengaruh yang dihasilkan oleh lubang dan diberi penambahan sengkang spiral dengan jarak yang bervariasi dapat meningkatkan kekuatan dari beton serta memberikan daktilitas tambahan pada kolom. Hasil paling optimum terjadi pada kondisi kolom dengan jarak sengkang 50 mm dengan kenaikan rata-rata sebesar 49%.

Column is a bearing element to maintain stability, stress, due to the influence of compressive axial loads. The compressive strength of the column can be increased by the use of spiral stirrups. The purpose of this research is to test a short column with a cylinder section with a diameter of 15 cm and a height of 30 cm with a quality of 29.05 MPa. The study used column variations consisting of 2 types of objects, namely plain without reinforcement and spiral diagonal. The cross section of the column is solid and has circular holes with a diameter of 2.5 cm, a diameter of 5 cm, and a diameter of 7.5 cm. Spiral stirrups used a distance of 2.5 cm, 5 cm, 7.5 cm and a distance of 10 cm. A total of 40 specimens were tested and axial compressive load testing was carried out until the maximum state or destroyed. From the results of the study it was found that the effect generated by the holes and the addition of spiral stirrups at a distance can increase the strength of the concrete and provide additional ductility to the column. The optimal results occurred in the column conditions with a stirrup 50 mm with an average increase of 49%.

Kata Kunci : Rongga, Jarak, Tekan Kolom

  1. S2-2021-419827-abstract.pdf  
  2. S2-2021-419827-bibliography.pdf  
  3. S2-2021-419827-tableofcontents.pdf  
  4. S2-2021-419827-title.pdf