Aluminium sekrap merupakam logam daur ulang yang sering digunakan sebagai bahan baku industri karena sifatnya yang tahan korosi, penghantar listrik dan panas yang baik, dan ringan. Penelitian ini bertujuan untuk mempelajari pengaruh temperatur cetakan terhadap struktur mikro dan kekerasan pada aluminium sekrap. Hasil pengujian komposisi dengan Spektometer Metal Scan menunjukan presentase aluminium 89,80% sedangkan silikon 6,19%. Paduan Al-Si dilebur pada tungku peleburan dengan temperatur 660ºC dan dituang dengan variasi temperatur cetakan yaitu 38°C, 150°C, 200°C, 250°C, 275°C, 300°C, 350°C, dan 400°C. Laju pendinginan spesimen diukur dengan termometer inframerah setiap 10 menit selama satu jam menunjukkan rata penurunan temperatur tercepat 45,6ºC yaitu cetakan 38ºC, sedangkan penurunan terlambat 17,2ºC pada cetakan 400ºC. Pre-heating pada cetakan mempengaruhi struktur silikon menjadi lebih besar dan jarak lebih longgar, berbeda dengan cetakan tanpa pre-heating silikon memiliki ukuran lebih kecil dengan jarak yang rapat. Hasil pengujian kekerasan vickers tertinggi yaitu temperatur 38°C sebesar 122,54 VHN, kekerasan terendah pada temperatur 400ºC yaitu 81,25 VHN.

Aluminum scrap is a recycled metal that is often used as an industrial raw material because of its corrosion-resistant nature, good conductance of electricity and heat, and lightweight. This study aims to study the effect of mold temperature on microstructure and hardness of scrap aluminum. The results of composition testing with a Metal Scan Spectometer showed an aluminum percentage of 89.80% while silicon 6.19%. Al-Si alloys are melted in a melting furnace with a temperature of 660ºC and poured with a variation of the mold temperature that is 38°C, 150°C, 200°C, 250°C, 275°C, 300°C, 350°C, and 400°C. The cooling rate of the specimens measured with an infrared thermometer every 10 minutes for one hour showed the fastest average temperature drop of 45.6ºC, which was a 38ºC mold, while a late decrease of 17.2ºC in a 400ºC mold. Pre-heating of the mold affects the structure of the silicon becomes larger and the distance is more loose, in contrast to the mold without pre-heating the silicon has a smaller size with a tight distance. The highest vickers hardness test results are 38°C temperature of 122.54 VHN, the lowest hardness at a temperature of 400ºC which is 81.25 VHN.

Kata Kunci : variasi temperatur cetakan/variation temperature of casting metal-mold

  1. D3-2020-401789-abstract.pdf  
  2. D3-2020-401789-bibliography.pdf  
  3. D3-2020-401789-tableofcontent.pdf  
  4. D3-2020-401789-title.pdf