Laporkan Masalah

EVALUASI STRUKTUR PERMUKAAN DARI IMPLAN BERBAHAN METAL YANG DIPRODUKSI LOKAL DAN KORELASI DENGAN PROLIFERASI OSTEOBLAS DAN FIBROBLAS

RONALD ISKANDAR, dr. Tedjo Rukmoyo, Sp.OT(K),FICS; dr. Yudha Mathan Sakti, Sp.OT(K)

2019 | Tesis-Spesialis | ORTHOPAEDI DAN TRAUMATOLOGI

Latar Belakang Indonesia telah memulai membuat implan berbahan metal yang diproduksi lokal. Evaluasi dari produksi lokal tersebut dapat dilakukan dengan pengukuran sifat permukaan material, dimana struktur permukaan material mempunyai pengaruh yang besar karena permukaan berkontak langsung dengan jaringan tubuh. Struktur permukaan implan mempengaruhi proliferasi osteoblast. Material dan Metode Penelitian ini merupakan penelitian eksperimental dari 5 jenis material berbahan metal yang diproduksi lokal. Material tersebut diukur kekasaran permukaan, sudut kontak, bioavailabilitas osteoblast dan fibroblas. Parameter ini dianalisa dan dibandingkan dengan hasil dari produksi standar, dan dianalisa korelasi antar parameter tersebut. Hasil Hasil kekasaran permukaan tertinggi pada Titanium Ti-GR2 (Ra 3.986 ± 2.043 µm) dan yang terendah pada Stainless steel AISI 316 L COR (1.640 ± 0.960 µm). Hasil sudut kontak yang paling besar pada Stainless steel AISI LVM (78.721 ± 2.833 derajat) dan yang terendah pada Titanium Ti-V-Al (43.218 ± 4.586 derajat). Bioavailabilitas osteoblast berkisar dari 68.25 - 84.79 % dan bioavailabilitas fibroblas berkisar dari 63.98 - 90.55 %. Korelasi antara kekasaran permukaan dengan bioavailabilitas osteoblas adalah p = 0.014, r 0.857 dan fibroblas p = 0.003, r 0.929. Kesimpulan Kekasaran permukaan dari material berbahan metal yang diproduksi lokal sesuai dengan hasil proses grinding yang dihasilkan oleh metode produksi umumnya. Material berbahan metal yang diproduksi lokal kami mempunyai sifat hidrofilik. Semakin tinggi kekasaran permukaan akan meningkatkan bioavailabilitas osteoblas dan fibroblas.

Background Indonesia has started to make local machinery metal-based implant. Evaluation of local machinery processing can be done with measurement of surface properties of material. The surface properties of a medical implant is of great importance since the surface is in direct contact with the host tissue. Surface properties influences osteoblastic proliferation. Materials and Methods This was an experimental study of our 5 local machinery metal-based materials from stainless steel and titanium alloy. Those materials were measured for the surface roughness, contact angle, bioavailability of osteoblast and fibroblast. These parameters analyzed and compared with result from common production method, and analyzed the correlation between those parameters. Results The highest surface roughness was in Titanium Ti-GR2 material (Ra 3.986 ± 2.043 µm ) and the lowest is Stainless steel AISI 316 L COR (1.640 ± 0.960 µm). The highest contact angle was in Stainless steel AISI LVM material (78.721 ± 2.833 degree) and the lowest is Titanium Ti-V-Al (43.218 ± 4.586 degree). The bioavailability osteoblast was range from 68.25 % - 84.79% and bioavailability fibroblast was range from 63.98 % - 90.55 %. The correlation between surface roughness on these material with bioavailability of osteoblast is p = 0.014, r 0.857 and fibroblast p = 0.003, r 0.929. Conclusion Surface roughness of our local machinery metal-based material is consistent with grinding result produced by common production method. Our local machinery metal-based material has hydrophilic nature. The higher surface roughness will increase the bioavailability of osteoblast and fibroblast.

Kata Kunci : Stainless steel, Titanium alloy, kekasaran permukaan, sifat kebasahan, bioavailabilitas osteoblas, bioavailabilitas fibroblas

  1. S2-2019-361084-abstract.pdf  
  2. S2-2019-361084-bibliography.pdf  
  3. S2-2019-361084-tableofcontent.pdf  
  4. S2-2019-361084-title.pdf