KENDALI INVERTER-FULLBRIDGE SATU FASE SEBAGAI KOMPENSATOR DAYA REAKTIF

ANANG BUDHI NUGROHO, Eka Firmansyah, S.T., M.Eng., Ph.D.; Dr. Eng. Suharyanto, S.T., M.Eng.

2018 | Tesis | S2 Teknik Elektro

Jatuh tegangan pada sistem distribusi merupakan indikator bahwa sistem kekurangan daya reaktif. Hal ini dikarenakan adanya impedansi jaringan yang bersifat resistive-inductive. Hal ini dapat diatasi dengan inverter yang dikendalikan untuk mengkompensasi daya reaktif. Kelebihan inverter adalah mudah dikonfigurasi untuk berbagai macam fungsi. Pada penelitian ini menyajikan konfigurasi kendali inverter sebagai kompensator daya reaktif. Metode yang digunakan adalah kendali arus proportional integrator (PI) berbasis transformasi dq. Secara sederhana untuk menghasilkan daya reaktif pada inverter, yaitu dengan cara mengatur domain arus (Idref = 0), sementara domain arus (Iqref) diatur sesuai dengan kebutuhan. Phase locked loop (PLL) digunakan untuk menjamin inverter dapat tersinkonisasi secara baik dengan grid. Berdasarkan hasil analisis dengan kendali arus PI, profil tegangan beban dapat dinaikkan dan stabil pada kondisi 311 Vpeak, sementara daya reaktif yang dihasilkan inverter sebesar 298 VAR dengan steady state error mencapai 0.11% dari referensi daya tanpa osilasi.

Voltage drop across the distribution system is an indicator that the system lacks of reactive power. This is caused by resistive-inductive network impedance. It can be overcome with controlled inverters to compensate for reactive power. The advantages of an inverter are easily configurable for a wide range of functions. In this study an inverter is investigated to be operated as a reactive power compensator. The method used is current control with proportional integrator (PI) compensator based on DQ transformation. Simply to generate the reactive power in the inverter is by setting the current domain (Idref = 0), while the current domain (Iqref) is set according to need. Phase locked loop (PLL) is added so that the inverter can be well synchronized with the grid. Based on the analysis with PI current control, the local load voltage profile rises and stable at 311 Vrms and the reactive power that has been produced by the inverter is 298 VAR with steady state error reaching 0.11% of the reference power without oscillation.

Kata Kunci : Kata kunci : inverter-fullbridge satu fase, kompensator daya reaktif, kendali arus proportional integrator, jatuh tegangan.


    Tidak tersedia file untuk ditampilkan ke publik.