Laporkan Masalah

NILAI DIAGNOSTIK EOSINOPENIA PADA SEPSIS DI ICU RSUP DR. SARDJITO

DEWANG SADIYANTO, Dr. dr. Sudadi, SpAn, KNA, KAR; dr. Calcarina Fitriani R.W., SpAn, KIC

2017 | Tesis-Spesialis | SP ILMU ANESTESIOLOGI DAN REANIMASI

Latar belakang : Infeksi akut dapat menyebabkan eosinopenia melalui beberapa mekanisme yaitu pengumpulan eosinofil di tempat inflamasi, penekanan produksi dan pelepasan eosinofil matang di sumsum tulang. Tujuan penelitian ini adalah untuk mengetahui apakah eosinopenia mempunyai nilai diagnostik yang dapat digunakan sebagai penanda kejadian sepsis di ICU RSUP dr. Sardjito. Metode : Penelitian dilakukan dengan metode case-control retrospektif. Pengambilan data dilakukan di Instalasi Catatan Medik RSUP Dr. Sardjito Yogyakarta selama 7 minggu (September - Oktober 2016). Subyek : 70 pasien sepsis dan non-sepsis yang menjalani rawat inap di ICU RSUP dr. Sardjito antara bulan Januari 2015 hingga Juni 2016. Hasil : Hubungan eosinopenia dengan sepsis diuji dengan fisher's exact test dan didapatkan hasil p=0,493 (p>0,05). Digunakan uji fisher's karena secara statistik didapatkan ada >20% dari kolom yang nilainya terisi <5 (dalam hal ini nilai nol pada pasien non-sepsis dengan non-eosinopenia). Kesimpulan : Eosinopenia tidak mempunyai nilai diagnostik dalam mendiagnosis sepsis karena kondisi eosinopenia tidak berhubungan dengan kondisi sepsis di ICU RSUP dr. Sardjito Yogyakarta.

Background : Acute infection can cause eosinopenia through several mechanism such as eosinophil aggregation in site of inflammation, suppression of production and release of mature eosinophil in bone marrow. The objective of this study is to analyze whether eosinopenia has a diagnostic value as a sepsis marker in ICU RSUP dr. Sardjito. Methods : It was a retrospective case-controlled study. Data sampling was held on Medical Record Installation of RSUP Dr. Sardjito Yogyakarta for 7 weeks (September - October 2016). Subjects : 70 sepsis and non-sepsis patients who had been hospitalized in ICU RSUP dr. Sardjito between January 2015 and Juni 2016. Results : Correlation of eosinopenia and sepsis was tested by fisher's exact test and showed p=0,493 (p>0,05). P value was used from fisher's exact test because there is a value >20% from one of the statiscal column that has value <5 (zero patient on non-sepsis patient with non-eosinopenia) and chi square test was not applicable. Conclusion : Eosinopenia did not have diagnostic value as a sepsis marker on sepsis patients in ICU RSUP dr. Sardjito.

Kata Kunci : Sepsis, Eosinopenia, Diagnostik


    Tidak tersedia file untuk ditampilkan ke publik.