Pemilihan Insulator String untuk Mengatasi Flashover Akibat Kontaminan di PLTU Adipala Indonesia Power

ANDI RENALDY N M, Ir. Tumiran, M. Eng., Ph. D.;Mochammad Wahyudi, S.T., M.T.

2022 | Skripsi | S1 TEKNIK ELEKTRO

Flashover merupakan fenomena kegagalan isolasi yang terjadi pada permukaan isolator. Flashover sering terjadi di lingkungan isolator dengan tingkat kontaminasi yang tinggi seperti dekat pantai. PLTU Adipala dipilih menjadi objek penilitian sebab teridentifikasi kerap mengalami flashover. Hal ini disebabkan oleh lingkungan isolator PLTU Adipala yang dekat dengan sumber kontaminasi. Salah satu mitigasi flashover akibat kontaminan adalah pemilihan isolator dengan bentuk yang optimal. Menurut standar IEC/TS 60815:2008, proses pemilihan isolator diperlukan data terkait site pollution severity (SPS). Evaluasi SPS untuk lingkungan isolator PLTU Adipala belum pernah dilakukan. Oleh karena itu, CP ini dilaksanakan dengan tujuan mengevaluasi SPS lingkungan PLTU Adipala dan memilih isolator baru dengan material komposit yang sesuai dengan kelas SPS yang telah ditentukan. Pemilihan isolator menggunakan acuan standar IEC/TS 60815:2008 dan SPLN T5.010-1:2015. Proses yang dilakukan dalam pemilihan isolator secara bertahap, yakni pemilihan metode pendekatan, parameter input, evaluasi SPS, pemilihan material, pemilihan profil, pemilihan produk, pemodelan 3D, pengecekan parameter profil, dan perhitungan final minimum creepage distance. Pelaksanaan CP ini menggunakan metode pendekatan 3 karena keterbatasan data dan waktu. Hasil identifikasi sampel kontaminan menunjukkan kontaminan yang menempel pada permukaan isolator di PLTU Adipala didominasi oleh fly ash dan garam yang merupakan kontaminan tipe A. Kelas SPS untuk lingkungan PLTU Adipala adalah very heavy dengan nilai RUSCD yang didapatkan adalah 53,7 mm/kV. Isolator yang dipilih adalah isolator dengan material komposit silicone rubber dengan profil isolator alternating. Isolator yang dipilih merupakan isolator komposit dari CTC Insulator dengan tipe CS160SB2925/16350 yang sudah sesuai dengan standar IEC/TS 60815-3:2008 dan SPLN T5.010-1:2015.

Flashover is an insulation failure phenomenon that occurs on the insulator surface. Flashover often occurs in environments with high levels of contamination. PLTU Adipala was chosen as the object of research because it was identified that it often experiences flashovers. This is caused by the environment of the PLTU Adipala, which is close to the source of contamination. One of the flashover mitigations due to contaminants is the selection of an insulator with an optimal shape. According to the IEC/TS 60815:2008 standard, the process of selecting an insulator requires data related to site pollution severity (SPS). The SPS evaluation for the PLTU Adipala environment has never been done. Therefore, this CP was carried out with the aim of evaluating the environmental SPS of the PLTU Adipala and selecting a new insulator with composite materials that match the predetermined SPS class. The selection of insulators uses standard references IEC/TS 60815:2008 and SPLN T5.010-1:2015. The staged process of selecting insulators, which includes selecting approach methods, input parameters, SPS evaluation, material selection, profile selection, product selection, 3D modeling, checking profile parameters, and calculating the final minimum creepage distance. This CP implementation uses approach 3 due to data and time limitations. The results of the identification of contaminant samples showed that the contaminants attached to the surface of the insulator at the PLTU Adipala were dominated by fly ash and salt, which are type A contaminants. The SPS class for the PLTU Adipala environment is very heavy, with the RUSCD value obtained being 53.7 mm/kV. The selected insulator is an insulator with a silicone rubber composite material and an alternating insulator profile. The selected insulator is a composite insulator from CTC Insulator with type CS160SB2925/16350, which complies with IEC/TS 60815-3:2008 and SPLN T5.010-1:2015 standards.

Kata Kunci : Isolator, Flashover, Fly Ash, PLTU, Site Pollution Severity